Plastic membrane electrode for the potentiometric determination of pethidine hydrochloride in pharmaceutical preparations

被引:9
作者
Liu, ZH
Wen, ML [1 ]
Yao, Y
Xiong, J
机构
[1] Yunnan Univ, Dept Chem, Kunming 650091, Yunnan, Peoples R China
[2] Yunnan Univ, Expt Ctr, Kunming 650091, Yunnan, Peoples R China
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 368卷 / 04期
关键词
D O I
10.1007/s002160000463
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel poly(vinyl chloride) membrane electrode with dibutyl phthalate as plasticizer based on the pethidine-tetraphenylborate ion-association complex as ion-exchange site for the determination of pethidine hydrochloride in injections and tablets was developed. A linear response for 1 x 10(-5) to 1 x 10(-2) mol/L drug with a slope of 51.77 mV\decade was established. The optimum pH range was 2-8. The lower detection limit was 2.18 x 10(-6) mol/L. There were negligible interferences from a number of inorganic and organic cations and some common drug excipients. The electrode proposed had been successfully applied to determine pethidine hydrochloride in tablets and injections. The results correlated well with those obtained by the United States Pharmacopoeia standard procedure.
引用
收藏
页码:335 / 337
页数:3
相关论文
共 50 条
  • [11] Potentiometric Method for the Determination of Lamivudine and Dothiepin Hydrochloride in Pharmaceutical Preparations
    Abdel-Gawad, Fatma M.
    Helmy, Ahmed G.
    Mohamed, Eman F.
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (02): : 222 - 235
  • [12] PLASTIC MEMBRANE-ELECTRODE FOR SELECTIVE DETERMINATION OF DICLOFENAC (VOLTAREN) IN PHARMACEUTICAL PREPARATIONS
    HASSAN, SSM
    ABDELAZIZ, RM
    ABDELSAMAD, MS
    [J]. ANALYST, 1994, 119 (09) : 1993 - 1996
  • [13] POTENTIOMETRIC DETERMINATION OF EPHEDRINE HYDROCHLORIDE USING PLASTIC MEMBRANE ION-SELECTIVE ELECTRODE
    ZAREH, MM
    ISSA, YM
    SHOUKRY, AF
    SHOHAIB, RE
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1993, 58 (04) : 371 - 376
  • [14] Determination of pyridoxine hydrochloride in pharmaceutical preparations by calixarene based potentiometric sensor
    Vaze, V. D.
    Srivastava, A. K.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (01) : 177 - 182
  • [15] Novel PVC-membrane electrode for flow injection potentiometric determination of Biperiden in pharmaceutical preparations
    Khaled, Elmorsy
    EI-Sabbagh, Inas A.
    El-Kholy, N. G.
    Ghahni, E. Y. Abdel
    [J]. TALANTA, 2011, 87 : 40 - 45
  • [16] Potentiometric determination of antihistaminic diphenhydramine hydrochloride in pharmaceutical preparations and biological fluids using screen-printed electrode
    Frag, Eman Y. Z.
    Mohamed, Gehad G.
    El-Sayed, Wael G.
    [J]. BIOELECTROCHEMISTRY, 2011, 82 (02) : 79 - 86
  • [17] Potentiometric membrane sensors for the selective determination of cinnarizine in pharmaceutical preparations
    Hassan, SSM
    AbdelAziz, RM
    Abbas, AB
    [J]. ANALYTICA CHIMICA ACTA, 1996, 321 (01) : 47 - 52
  • [18] Spectrophotometric and Potentiometric Methods for the Determination of Cefprozil, Dropropizine and Tizanidine Hydrochloride in Pharmaceutical Preparations
    Abdel-Gawad, F. M.
    Mostafa, C. S.
    Abdel-Hamid, S. M.
    Abbas, N. A.
    [J]. EGYPTIAN JOURNAL OF CHEMISTRY, 2010, 53 (01): : 101 - 115
  • [19] POTENTIOMETRIC DETERMINATION OF IODINE IN PHARMACEUTICAL PREPARATIONS
    VANDEPUTTE, M
    DRYON, L
    DEHERTOGH, L
    MASSART, DL
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1979, 68 (11) : 1416 - 1418
  • [20] Flow-injection potentiometric determination of clobutinol hydrochloride in pure state and pharmaceutical preparations
    N. T. Abdel-Ghani
    R. M. El Nashar
    S. M. Hamed
    [J]. Journal of Analytical Chemistry, 2007, 62 : 977 - 986