Personnel exposure to scattered radiation during radiography of the distal interphalangeal joint in the horse using a portable X-ray machine

被引:1
|
作者
Sterc, J. [1 ]
Lepkova, R. [1 ]
机构
[1] Univ Vet & Pharmaceut Sci, Brno, Czech Republic
关键词
radiation exposure; radiation dosage; pre-purchase examination; radiological examination; scatter radiation;
D O I
10.2754/avb200776010105
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Radiography of the distal interphalangeal joints of two limbs of a cadaver of a horse weighing 550 kg was conducted in the present study. The examination was performed on lateromedial, palmaroproximal-palmarodistal views and on dorsoproximal-palmarodistal, dorsolateral-palmaromedial, dorsomedial-palmarolateral views of a raised limb placed on a navicular block, and of weight-bearing limbs. During the examination, doses of scattered radiation were measured at the sites of radiographer, assistant holding a film cassette and assistant positioning the examined limb or the opposite one. The lowest radiation dose was received by the assistant holding the cassette behind the examined region; a total equivalent dose of 183.6 - 201.7 nSv was received by his hands and genitals, and 110.8 - 113.3 nSv by his eye tens and neck during the examination of the distal interphalangeal joint. The radiographer was exposed to higher radiation; an equivalent dose of 846.6 - 854.1 nSv was received by his hands and genitals, and 271.8 - 328.2 nSv by the eye lens and the neck. The highest scattered radiation dose was received by the assistant positioning the examined limbs; equivalent doses were 7751 - 9354 nSv (hands), 1117.3 - 1119.5 nSv (genitals), and 880.6 - 1096.2 nSv (eye lens and neck). The equivalent dose values measured, received by the radiographer and the assistants during the examination of the distal interphalangeal joint seem to be very low relative to radiation exposure limits. However, it must be taken into account that the personnel involved in radiography is also exposed to scattered radiation during other examinations where radiation doses are often much higher. These results indicate the necessity to use protective lead aprons, gloves and collars during radiography of the distal interphalangeal joint.
引用
收藏
页码:105 / +
页数:11
相关论文
共 10 条
  • [1] Scatter radiation levels in X-ray rooms during chest radiography
    Onu, Chiamaka Peace
    Nzotta, Chukwuemeka Christian
    APPLIED RADIATION AND ISOTOPES, 2024, 212
  • [2] Radiation exposure from diagnostic radiography: an assessment of X-ray beam collimation practice in some Nigerian Hospitals
    Okeji, Mark C.
    Anakwue, Angel Mary
    Agwuna, Kenneth
    INTERNET JOURNAL OF MEDICAL UPDATE, 2010, 5 (02) : 31 - 33
  • [3] Patient and physician radiation exposure during minimally invasive lumbar decompression: A prospective assessment of X-ray exposure risks
    Mekhail, Nagy
    Topalsky, Krista
    Templeton, Erin
    Armanyous, Sherif
    Prayson, Nicholas
    Olde, Carl
    Costandi, Shrif
    PAIN PRACTICE, 2024, 24 (04) : 600 - 608
  • [4] Radiation exposure during chest X-ray examinations in a premature intensive care unit: phantom studies
    Duetting, T
    Foerste, B
    Knoch, T
    Darge, K
    Troeger, J
    PEDIATRIC RADIOLOGY, 1999, 29 (03) : 158 - 162
  • [5] Radiation exposure during chest X-ray examinations in a premature intensive care unit: phantom studies
    T. Duetting
    Birgit Foerste
    Thilo Knoch
    Kassa Darge
    Jochen Troeger
    Pediatric Radiology, 1999, 29 : 158 - 162
  • [6] Feasibility of the use of a pixelated transmission chamber to measure scattered-radiation in projection radiography: I. Monte Carlo analysis of x-ray scatter propagation and detector modeling
    Cipriano-Urbano, I. E.
    Garnica-Garza, H. M.
    APPLIED RADIATION AND ISOTOPES, 2017, 122 : 193 - 201
  • [7] Radiation Exposure of Children in Pediatric Radiology Part 4: Entrance Doses Achieved During the X-ray Examination of the Chest
    Seidenbusch, M. C.
    Schneider, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (12): : 1082 - 1103
  • [8] Efficacy and User Experience of a Novel X-Ray Shield on Operator Radiation Exposure During Cardiac Catheterization: A Randomized Controlled Trial
    Davidsen, Cedric
    Ytre-Hauge, Kristian
    Samnoy, Andreas Tefre
    Vikenes, Kjell
    Lancellotti, Patrizio
    Tuseth, Vegard
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (12) : 745 - 753
  • [9] Exposure dose measurement during diagnostic pediatric X-ray examination using an optically stimulated luminescence (OSL) dosimeter based on precise dose calibration taking into consideration variation of X-ray spectra
    Asahara, Takashi
    Hayashi, Hiroaki
    Goto, Sota
    Tomita, Emi
    Kimoto, Natsumi
    Mihara, Yoshiki
    Asakawa, Takumi
    Kanazawa, Yuki
    Katsumata, Akitoshi
    Higashino, Kosaku
    Yamashita, Kazuta
    Okazaki, Tohru
    Hashizume, Takuya
    RADIATION MEASUREMENTS, 2018, 119 : 209 - 219
  • [10] Assessment of the Occupational Radiation Dose from a Handheld Portable X-ray Unit During Full-mouth Intraoral Dental Radiographs in the Dog and the Cat - A Pilot Study
    Villamizar-Martinez, Lenin A. A.
    Losey, Jeannie
    JOURNAL OF VETERINARY DENTISTRY, 2024, 41 (02) : 106 - 113