Effect of Power System Harmonic on Degradation process of Transformer Insulation System
被引:11
作者:
Sumaryadi
论文数: 0引用数: 0
h-index: 0
机构:
PT PLN Persero P3B Jawa Bali Reg, Jakarta Banten J1 Mayjen Sutoyo 1 Cililitan, Jakarta Timur, IndonesiaPT PLN Persero P3B Jawa Bali Reg, Jakarta Banten J1 Mayjen Sutoyo 1 Cililitan, Jakarta Timur, Indonesia
Sumaryadi
[1
]
Gumilang, Harry
论文数: 0引用数: 0
h-index: 0
机构:
PT PLN Persero P3B Jawa Bali Reg, Jakarta Banten J1 Mayjen Sutoyo 1 Cililitan, Jakarta Timur, IndonesiaPT PLN Persero P3B Jawa Bali Reg, Jakarta Banten J1 Mayjen Sutoyo 1 Cililitan, Jakarta Timur, Indonesia
Gumilang, Harry
[1
]
Susilo, Achmad
论文数: 0引用数: 0
h-index: 0
机构:
PT PLN Persero P3B Jawa Bali Reg Jawa Tengah & DI, Ungaran, IndonesiaPT PLN Persero P3B Jawa Bali Reg, Jakarta Banten J1 Mayjen Sutoyo 1 Cililitan, Jakarta Timur, Indonesia
Susilo, Achmad
[2
]
机构:
[1] PT PLN Persero P3B Jawa Bali Reg, Jakarta Banten J1 Mayjen Sutoyo 1 Cililitan, Jakarta Timur, Indonesia
[2] PT PLN Persero P3B Jawa Bali Reg Jawa Tengah & DI, Ungaran, Indonesia
来源:
ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3
|
2009年
关键词:
Harmonic;
transformer insulation degradation and DGA;
D O I:
10.1109/ICPADM.2009.5252458
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
Harmonic is one of common phenomenon occurred during power system operation, especially when the non linear load applied within the power system. These harmonic will affect to the transformer, such as increasing hysteresis losses (magnetization) on steel and iron of transformer core, where the value is temperature depended. Degradation of transformer insulation can be driven by this temperature increasing. The harmonic that monitored continuously can be use as a reference parameter of degradation level of transformer insulation. To determine the actual condition of transformer insulation we developed Dissolved Gas Analysis (DGA) to enrich data analysis and using power quality monitoring to determine the power condition. This paper will discuss the possibility effect of harmonic phenomenon due to degradation process of transformer insulation system based on DGA and power quality analysis.