Impact of neointimal tissue characterization and heterogeneity of bare-metal stents and drug-eluting stents on the time course after stent implantation evaluated by integrated backscatter intravascular ultrasound

被引:6
作者
Yoshizane, Takashi [1 ]
Tanaka, Shinichiro [2 ]
Abe, Shintaro [1 ]
Ueno, Takahiro [1 ]
Goto, Yoshiaki [1 ]
Kojima, Tai [1 ]
Iwama, Makoto [1 ]
Arai, Masazumi [1 ]
Noda, Toshiyuki [1 ]
Kawasaki, Masanori [3 ]
机构
[1] Gifu Prefectural Gen Med Ctr, Dept Cardiol, 4-6-1 Noishiki, Gifu 5008226, Japan
[2] Asahi Univ Hosp, Gifu, Japan
[3] Gifu Univ, Grad Sch Med, Gifu, Japan
关键词
Neoatherosclerosis; Tissue signal distribution; Integrated backscatter intravascular ultrasound; Bare-metal stent; Drug-eluting stent; CORONARY PLAQUES; HISTOLOGY; NEOATHEROSCLEROSIS; RESTENOSIS; PATHOLOGY;
D O I
10.1007/s00380-019-01410-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pathological studies have suggested the different process of in-stent restenosis (ISR) of bare-metal stents (BMS) and drug-eluting stents (DES). Here, we evaluated the components of neointimal tissue using integrated backscatter intravascular ultrasound (IB-IVUS) and focused on the time course after stent implantation and tissue signal distribution. We evaluated 125 lesions of 125 patients who underwent target lesion revascularization for ISR (BMS: n = 73, DES: n = 52). Volume analysis of a 4-mm length centered on a minimum lumen area in every 1-mm cross-sectional area was performed. For IB-IVUS analysis, color-coded maps were constructed from the default setting based on the integrated backscatter (IB) values (middle-IB value, green: fibrous and low-IB value, blue: lipid pool). For the neointimal tissue volume, we evaluated the ratios of the green (%G) and blue (%B) areas. Tissue signal distribution (TD) was also obtained from the default setting based on IB values in each pixel of IB-IVUS imaging. We compared values of neointimal tissues measured by IB-IVUS between the DES and BMS and time course. The observed period was longer after BMS implantation than after DES implantation (BMS: 2545 days, DES: 1233 days, p < 0.001). Overall, %G and %B were similar between the BMS and DES groups (%G: 55% and 51%, respectively, p = 0.10; %B: 36% and 38%, respectively, p = 0.51); however, TD was significantly higher in the DES group than in the BMS group (1091 vs. 1367, p < 0.001). TD in the DES group remained high during the follow-up periods. However, TD in the BMS group was low in the early phase and significantly increased over time (r = 0.56, p < 0.001). When analyzing the ISR within 2 years after stent implantation, the BMS was distinguished with a sensitivity of 66% and a specificity of 90% (cut-off value: TD = 1135, area under the curve 0.83, 95% confidence interval 0.74-0.92). TD could differentiate neointimal tissue after BMS implantation in the early phase. TD can be a useful index in the observation of neoatherosclerosis.
引用
收藏
页码:1639 / 1649
页数:11
相关论文
共 50 条
  • [41] The Effect of Shear Stress on Neointimal Response Following Sirolimus- and Paclitaxel-Eluting Stent Implantation Compared With Bare-Metal Stents in Humans
    Papafaklis, Michail I.
    Bourantas, Christos V.
    Theodorakis, Panagiotis E.
    Katsouras, Christos S.
    Naka, Katerina K.
    Fotiadis, Dimitrios I.
    Michalis, Lampros K.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) : 1181 - 1189
  • [42] Difference of Neoatherosclerosis Pattern in Lesions With In-Stent Restenosis Among Bare-Metal, First and Second Generation Drug-Eluting Stents
    Nakamura, Daisuke
    Nishino, Masami
    Yasumura, Keisuke
    Yasumoto, Koji
    Tanaka, Akihiro
    Mori, Naoki
    Yano, Masamichi
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    CIRCULATION, 2017, 136
  • [43] Risk of discontinuation of clopidogrel after 1 month following bare-metal stents: a propensity-score adjusted comparison with continued administration of clopidogrel after drug-eluting stents
    Christian M. Valina
    Sebastian Merz
    Nikolaus Löffelhardt
    Michael Amann
    Miroslaw Ferenc
    Christian Stratz
    Franz-Josef Neumann
    Willibald Hochholzer
    Journal of Thrombosis and Thrombolysis, 2018, 45 : 432 - 439
  • [44] Risk of discontinuation of clopidogrel after 1 month following bare-metal stents: a propensity-score adjusted comparison with continued administration of clopidogrel after drug-eluting stents
    Valina, Christian M.
    Merz, Sebastian
    Loeffelhardt, Nikolaus
    Amann, Michael
    Ferenc, Miroslaw
    Stratz, Christian
    Neumann, Franz-Josef
    Hochholzer, Willibald
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2018, 45 (03) : 432 - 439
  • [45] Difference of Optical Properties of Neointimal Tissue Between Restenosis After Drug-Eluting and Bare Metal Coronary Stent
    Shinke, Toshiro
    Kato, Hiroki
    Shite, Junya
    Nagoshi, Ryoji
    Sawada, Takahiro
    Kawamori, Hiroyuki
    Takaya, Tomofumi
    Hayashi, Takatoshi
    Yamada, Shinichiro
    Hirata, Kenichi
    CIRCULATION, 2010, 122 (21)
  • [46] Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials
    Alfonso, Fernando
    Perez-Vizcayno, Maria Jose
    del Blanco, Bruno Garcia
    Garcia-Touchard, Arturo
    Lopez-Minguez, Jose-Ramon
    Masotti, Monica
    Zueco, Javier
    Melgares, Rafael
    Mainar, Vicente
    Moreno, Raul
    Dominguez, Antonio
    Sanchis, Juan
    Bethencourt, Armando
    Moreu, Jose
    Cequier, Angel
    Marti, Vicens
    Otaegui, Imanol
    Bastante, Teresa
    Gonzalo, Nieves
    Jimenez-Quevedo, Pilar
    Cardenas, Alberto
    Fernandez, Cristina
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07)
  • [47] Outcomes With Intravascular Ultrasound-Guided Stent Implantation A Meta-Analysis of Randomized Trials in the Era of Drug-Eluting Stents
    Elgendy, Islam Y.
    Mahmoud, Ahmed N.
    Elgendy, Akram Y.
    Bavry, Anthony A.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04)
  • [48] Differential Changes in Plaque Behind the Stent After Bare-Metal and Drug-Eluting Stent Implantation in Humans: Implications for In-Stent Restenosis?
    Andreou, Loannis
    Shishido, Koki
    Antoniadis, Antonios P.
    Takahashi, Saeko
    Tsuda, Masaya
    Papafaklis, Michail I.
    Saito, Shigeru
    Coscun, Ahmet U.
    Feldman, Charles L.
    Stone, Peter H.
    CIRCULATION, 2014, 130
  • [49] Relation between renal function and neointimal tissue characteristics after drug-eluting stent implantation: Virtual histology-intravascular ultrasound analysis
    Hong, Young Joon
    Jeong, Myung Ho
    Choi, Yun Ha
    Park, Soo Young
    Rhew, Si Hyun
    Kim, Sung Soo
    Jeong, Young Wook
    Jeong, Hae Chang
    Cho, Jae Yeong
    Jang, Soo Young
    Lee, Ki Hong
    Park, Keun Ho
    Sim, Doo Sun
    Yoon, Nam Sik
    Yoon, Hyun Ju
    Kim, Kye Hun
    Park, Hyung Wook
    Kim, Ju Han
    Aim, Youngkeun
    Cho, Jeong Gwan
    Park, Jong Chun
    JOURNAL OF CARDIOLOGY, 2014, 64 (02) : 98 - 104
  • [50] Angiographic and 3D intravascular ultrasound assessment of overlapping bare metal stent and three different formulations of drug-eluting stents in patients with diabetes mellitus
    Kawaguchi, Ren
    Sabate, Manel
    Angiolillo, Dominick J.
    Jimenez-Quevedo, Pilar
    Suzuki, Nobuaki
    Corros, Cecilia
    Futamatsu, Hideki
    Alfonso, Fernando
    Hernandez-Antolin, Rosana
    Macaya, Carlos
    Bass, Theodore A.
    Costa, Marco A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (02) : 125 - 132