Impact of neointimal tissue characterization and heterogeneity of bare-metal stents and drug-eluting stents on the time course after stent implantation evaluated by integrated backscatter intravascular ultrasound

被引:6
作者
Yoshizane, Takashi [1 ]
Tanaka, Shinichiro [2 ]
Abe, Shintaro [1 ]
Ueno, Takahiro [1 ]
Goto, Yoshiaki [1 ]
Kojima, Tai [1 ]
Iwama, Makoto [1 ]
Arai, Masazumi [1 ]
Noda, Toshiyuki [1 ]
Kawasaki, Masanori [3 ]
机构
[1] Gifu Prefectural Gen Med Ctr, Dept Cardiol, 4-6-1 Noishiki, Gifu 5008226, Japan
[2] Asahi Univ Hosp, Gifu, Japan
[3] Gifu Univ, Grad Sch Med, Gifu, Japan
关键词
Neoatherosclerosis; Tissue signal distribution; Integrated backscatter intravascular ultrasound; Bare-metal stent; Drug-eluting stent; CORONARY PLAQUES; HISTOLOGY; NEOATHEROSCLEROSIS; RESTENOSIS; PATHOLOGY;
D O I
10.1007/s00380-019-01410-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pathological studies have suggested the different process of in-stent restenosis (ISR) of bare-metal stents (BMS) and drug-eluting stents (DES). Here, we evaluated the components of neointimal tissue using integrated backscatter intravascular ultrasound (IB-IVUS) and focused on the time course after stent implantation and tissue signal distribution. We evaluated 125 lesions of 125 patients who underwent target lesion revascularization for ISR (BMS: n = 73, DES: n = 52). Volume analysis of a 4-mm length centered on a minimum lumen area in every 1-mm cross-sectional area was performed. For IB-IVUS analysis, color-coded maps were constructed from the default setting based on the integrated backscatter (IB) values (middle-IB value, green: fibrous and low-IB value, blue: lipid pool). For the neointimal tissue volume, we evaluated the ratios of the green (%G) and blue (%B) areas. Tissue signal distribution (TD) was also obtained from the default setting based on IB values in each pixel of IB-IVUS imaging. We compared values of neointimal tissues measured by IB-IVUS between the DES and BMS and time course. The observed period was longer after BMS implantation than after DES implantation (BMS: 2545 days, DES: 1233 days, p < 0.001). Overall, %G and %B were similar between the BMS and DES groups (%G: 55% and 51%, respectively, p = 0.10; %B: 36% and 38%, respectively, p = 0.51); however, TD was significantly higher in the DES group than in the BMS group (1091 vs. 1367, p < 0.001). TD in the DES group remained high during the follow-up periods. However, TD in the BMS group was low in the early phase and significantly increased over time (r = 0.56, p < 0.001). When analyzing the ISR within 2 years after stent implantation, the BMS was distinguished with a sensitivity of 66% and a specificity of 90% (cut-off value: TD = 1135, area under the curve 0.83, 95% confidence interval 0.74-0.92). TD could differentiate neointimal tissue after BMS implantation in the early phase. TD can be a useful index in the observation of neoatherosclerosis.
引用
收藏
页码:1639 / 1649
页数:11
相关论文
共 50 条
  • [31] Can intravascular ultrasound guidance modify the efficacy of drug-eluting stent over bare-metal stent in an aorto-ostial lesion?
    Okabe, Teruo
    Kawamura, Akio
    Maekawa, Yuichiro
    Anzai, Toshihisa
    Iwanaga, Shiro
    Yoshikawa, Tsutomu
    Ogawa, Satoshi
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2011, 12 (02) : 105 - 110
  • [32] Comparison of neointimal morphology of in-stent restenosis with sirolimus-eluting stents versus bare metal stents: Virtual histology-intravascular ultrasound analysis
    Yamamoto Y.
    Otani H.
    Iwasaka J.
    Park H.
    Sakuma T.
    Kamihata H.
    Iwasaka T.
    Cardiovascular Intervention and Therapeutics, 2011, 26 (3) : 186 - 192
  • [33] Qualitative and Quantitative Assessment of Stent Restenosis by Optical Coherence Tomography - Comparison Between Drug-Eluting and Bare-Metal Stents
    Nagoshi, Ryoji
    Shinke, Toshiro
    Otake, Hiromasa
    Shite, Junya
    Matsumoto, Daisuke
    Kawamori, Hiroyuki
    Nakagawa, Masayuki
    Kozuki, Amane
    Hariki, Hirotoshi
    Inoue, Takumi
    Ohsue, Tsuyoshi
    Taniguchi, Yu
    Iwasaki, Masamichi
    Nishio, Ryo
    Hiranuma, Noritoshi
    Konishi, Akihide
    Kinutani, Hiroto
    Miyoshi, Naoki
    Takaya, Tomofumi
    Yamada, Shinichiro
    Yasaka, Yoshinori
    Hayashi, Takatoshi
    Yokoyama, Mitsuhiro
    Kato, Hiroki
    Kadotani, Makoto
    Ohnishi, Yoshio
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2013, 77 (03) : 652 - 660
  • [34] Mechanism of in-stent restenosis after second-generation drug-eluting stents (DES): is it different from bare-metal stents and first-generation DES?
    Kuramitsu, Shoichi
    Shirai, Shinichi
    Ando, Kenji
    JOURNAL OF THORACIC DISEASE, 2015, 7 (12) : E599 - E602
  • [35] Serum Inflammatory and Immune Marker Response After Bare-Metal or Drug-Eluting Stent Implantation Following Percutaneous Coronary Intervention
    Moohebati, Mohsen
    Falsoleiman, Homa
    Dehghani, Mashalla
    Fazlinezhad, Afsoon
    Daloee, Mehdi Hassanzadeh
    Esmaeili, Habib
    Parizadeh, Seyyed Mohammad Reza
    Tavallaie, Shima
    Rahsepar, Amir Ali
    Paydar, Roghayeh
    Kazemi-Bajestani, Seyyed Mohammad Reza
    Pourghadam-Yari, Hossein
    Rad, Mina Akbari
    Zoghdar-Moghadam, Talat
    Ghayour-Mobarhan, Majid
    Ferns, Gordon A.
    ANGIOLOGY, 2011, 62 (02) : 184 - 190
  • [36] Atherosclerotic plaque behind the stent changes after bare-metal and drug-eluting stent implantation in humans: Implications for late stent failure?
    Andreou, Ioannis
    Takahashi, Saeko
    Tsuda, Masaya
    Shishido, Koki
    Antoniadis, Antonios P.
    Papafaklis, Michail I.
    Mizuno, Shingo
    Coskun, Ahmet U.
    Saito, Shigeru
    Feldman, Charles L.
    Edelman, Elazer R.
    Stone, Peter H.
    ATHEROSCLEROSIS, 2016, 252 : 9 - 14
  • [37] Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents
    Matthias Sigler
    Julia Klötzer
    Thomas Quentin
    Thomas Paul
    Oliver Möller
    Molecular and Cellular Pediatrics, 2 (1)
  • [38] Clinical presentation and outcome of patients hospitalized for symptomatic in-stent restenosis treated by percutaneous coronary intervention: Comparison between drug-eluting stents and bare-metal stents
    De Labriolle, Axel
    Bonello, Laurent
    Lemesle, Gilles
    Steinberg, Daniel H.
    Roy, Probal
    Xue, Zhenyi
    Kaneshige, Kimberly
    Suddath, William O.
    Satler, Lowell F.
    Kent, Kenneth M.
    Pichard, Augusto D.
    Lindsay, Joseph
    Waksman, Ron
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (03) : 209 - 217
  • [39] Characterization of in-stent neointimal tissue components following drug-eluting stent implantation according to the phase of restenosis using a 40-MHz intravascular ultrasound imaging system
    Araki, Tadashi
    Nakamura, Masato
    Sugi, Kaoru
    JOURNAL OF CARDIOLOGY, 2014, 64 (5-6) : 423 - 429
  • [40] Comparison of drug-eluting versus bare-metal stents after rotational atherectomy for the treatment of calcified coronary lesions
    Mangiacapra, Fabio
    Heyndrickx, Guy R.
    Puymirat, Etienne
    Peace, Aaron J.
    Wijns, William
    De Bruyne, Bernard
    Barbato, Emanuele
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 154 (03) : 373 - 376