Impact of neointimal tissue characterization and heterogeneity of bare-metal stents and drug-eluting stents on the time course after stent implantation evaluated by integrated backscatter intravascular ultrasound

被引:6
|
作者
Yoshizane, Takashi [1 ]
Tanaka, Shinichiro [2 ]
Abe, Shintaro [1 ]
Ueno, Takahiro [1 ]
Goto, Yoshiaki [1 ]
Kojima, Tai [1 ]
Iwama, Makoto [1 ]
Arai, Masazumi [1 ]
Noda, Toshiyuki [1 ]
Kawasaki, Masanori [3 ]
机构
[1] Gifu Prefectural Gen Med Ctr, Dept Cardiol, 4-6-1 Noishiki, Gifu 5008226, Japan
[2] Asahi Univ Hosp, Gifu, Japan
[3] Gifu Univ, Grad Sch Med, Gifu, Japan
关键词
Neoatherosclerosis; Tissue signal distribution; Integrated backscatter intravascular ultrasound; Bare-metal stent; Drug-eluting stent; CORONARY PLAQUES; HISTOLOGY; NEOATHEROSCLEROSIS; RESTENOSIS; PATHOLOGY;
D O I
10.1007/s00380-019-01410-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pathological studies have suggested the different process of in-stent restenosis (ISR) of bare-metal stents (BMS) and drug-eluting stents (DES). Here, we evaluated the components of neointimal tissue using integrated backscatter intravascular ultrasound (IB-IVUS) and focused on the time course after stent implantation and tissue signal distribution. We evaluated 125 lesions of 125 patients who underwent target lesion revascularization for ISR (BMS: n = 73, DES: n = 52). Volume analysis of a 4-mm length centered on a minimum lumen area in every 1-mm cross-sectional area was performed. For IB-IVUS analysis, color-coded maps were constructed from the default setting based on the integrated backscatter (IB) values (middle-IB value, green: fibrous and low-IB value, blue: lipid pool). For the neointimal tissue volume, we evaluated the ratios of the green (%G) and blue (%B) areas. Tissue signal distribution (TD) was also obtained from the default setting based on IB values in each pixel of IB-IVUS imaging. We compared values of neointimal tissues measured by IB-IVUS between the DES and BMS and time course. The observed period was longer after BMS implantation than after DES implantation (BMS: 2545 days, DES: 1233 days, p < 0.001). Overall, %G and %B were similar between the BMS and DES groups (%G: 55% and 51%, respectively, p = 0.10; %B: 36% and 38%, respectively, p = 0.51); however, TD was significantly higher in the DES group than in the BMS group (1091 vs. 1367, p < 0.001). TD in the DES group remained high during the follow-up periods. However, TD in the BMS group was low in the early phase and significantly increased over time (r = 0.56, p < 0.001). When analyzing the ISR within 2 years after stent implantation, the BMS was distinguished with a sensitivity of 66% and a specificity of 90% (cut-off value: TD = 1135, area under the curve 0.83, 95% confidence interval 0.74-0.92). TD could differentiate neointimal tissue after BMS implantation in the early phase. TD can be a useful index in the observation of neoatherosclerosis.
引用
收藏
页码:1639 / 1649
页数:11
相关论文
共 50 条
  • [1] Impact of neointimal tissue characterization and heterogeneity of bare-metal stents and drug-eluting stents on the time course after stent implantation evaluated by integrated backscatter intravascular ultrasound
    Takashi Yoshizane
    Shinichiro Tanaka
    Shintaro Abe
    Takahiro Ueno
    Yoshiaki Goto
    Tai Kojima
    Makoto Iwama
    Masazumi Arai
    Toshiyuki Noda
    Masanori Kawasaki
    Heart and Vessels, 2019, 34 : 1639 - 1649
  • [2] Evaluation of in-stent neointimal tissue components using integrated backscatter intravascular ultrasound: comparison of drug-eluting stents and bare-metal stents
    Muraoka, Yoshitaka
    Sonoda, Shinjo
    Kashiyama, Kuninobu
    Kamezaki, Fumihiko
    Tsuda, Yuki
    Araki, Masaru
    Okazaki, Masahiro
    Otsuji, Yutaka
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07) : 1635 - 1641
  • [3] Evaluation of in-stent neointimal tissue components using integrated backscatter intravascular ultrasound: comparison of drug-eluting stents and bare-metal stents
    Yoshitaka Muraoka
    Shinjo Sonoda
    Kuninobu Kashiyama
    Fumihiko Kamezaki
    Yuki Tsuda
    Masaru Araki
    Masahiro Okazaki
    Yutaka Otsuji
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1635 - 1641
  • [4] Comparison of Angiographic Patterns and Tissue Characterizations of In-stent Neointimal Hyperplasia by Integrated Backscatter Intravascular Ultrasound Between Drug-Eluting Stents and Bare-Metal Stents
    Ando, Hirohiko
    Amano, Tetsuya
    Uetani, Tadayuki
    Yoshikawa, Daiji
    Isobe, Satoshi
    Izawa, Hideo
    Matsubara, Tatsuaki
    Ishii, Hideki
    Murohara, Toyoaki
    CIRCULATION, 2010, 122 (21)
  • [5] Neointimal Tissue Component Assessed by Tissue Characterization With 40 MHz Intravascular Ultrasound Imaging: Comparison of Drug-Eluting Stents and Bare-Metal Stents
    Tsujita, Kenichi
    Takaoka, Naoko
    Kaikita, Koichi
    Hokimoto, Seiji
    Horio, Eiji
    Sato, Koji
    Mizobe, Michio
    Nakayama, Naoki
    Kojima, Sunao
    Tayama, Shinji
    Sugiyama, Seigo
    Nakamura, Sunao
    Ogawa, Hisao
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (07) : 1068 - 1074
  • [6] Impact of Coronary Stent Fracture on Restenotic Neointimal Tissue Characterization After Drug-Eluting Stent Implantation An Integrated Backscatter Intravascular Ultrasound Study
    Uchida, Yasuhiro
    Ichimiya, Satoshi
    Ishii, Hideki
    Oishi, Hideo
    Aoki, Toshijiro
    Miki, Yusuke
    Kawamiya, Toshiki
    Ichimiya, Hitoshi
    Watanabe, Junji
    Kanashiro, Masaaki
    Hayano, Shinji
    Suzuki, Susumu
    Amano, Tetsuya
    Matsubara, Tatsuaki
    Murohara, Toyoaki
    INTERNATIONAL HEART JOURNAL, 2017, 58 (06) : 861 - 867
  • [7] Identification of independent risk factors for restenosis following bare-metal stent implantation: Role of bare-metal stents in the era of drug-eluting stents
    Park, Chang-Bum
    Park, Hoon-Ki
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (03) : 840 - 846
  • [8] The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography
    Sato, Kastsumasa
    Costopoulos, Charis
    Takebayashi, Hideo
    Naganuma, Toru
    Miyazaki, Tadashi
    Goto, Kenji
    Yamane, Hiroki
    Hagikura, Arata
    Kikuta, Yuetsu
    Taniguchi, Masahito
    Hiramatsu, Shigeki
    Ito, Hiroshi
    Colombo, Antonio
    Haruta, Seiichi
    JOURNAL OF CARDIOLOGY, 2014, 64 (5-6) : 488 - 495
  • [9] Neointimal tissue characterization after implantation of drug-eluting stents by optical coherence tomography: quantitative analysis of optical density
    Nishino, Setsu
    Sakuma, Masashi
    Kanaya, Tomoaki
    Nasuno, Takahisa
    Tokura, Michiaki
    Toyoda, Shigeru
    Abe, Shichiro
    Nakamura, Daisuke
    Tanaka, Kentaro
    Attizzani, Guiherme F.
    Bezerra, Hiram G.
    Costa, Marco A.
    Inoue, Teruo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (11) : 1971 - 1978
  • [10] Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents
    Koo, Bon-Kwon
    Waseda, Katsuhisa
    Ako, Junya
    Hasegawa, Takao
    Shimohama, Takao
    Nakatani, Daisaku
    Otake, Hiromasa
    Yamasaki, Masao
    Sakurai, Ryota
    Tsujino, Ichizo
    Honda, Yasuhiro
    Fitzgerald, Peter J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 144 (01) : 132 - 134