Efficacy of anti-retraction devices in preventing bacterial contamination of dental unit water lines

被引:31
|
作者
Berlutti, F
Testarelli, L
Vaia, F
De Luca, M
Dolci, G
机构
[1] Univ Roma La Sapienza, Dipartimento Sci Sanita Pubbl, Sez Microbiol, I-00185 Rome, Italy
[2] Univ Roma La Sapienza, Ist Clin Odontoiatr, I-00166 Rome, Italy
关键词
anti-retraction valves; bacterial contamination; dental unit water lines;
D O I
10.1016/S0300-5712(03)00004-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. In this study we examine the efficacy of anti-retraction devices in preventing microbial contamination of dental unit water lines (DUWLs). Methods. The study was performed on 54 randomly selected DUs in use at private and public institutions for over six months. The selected DUs were all currently commercially available. To evaluate the efficiency of anti-retraction devices, two different methods were employed, mechanical and microbiological. The ADA/ANSI specification #47 (corresponding to a water retraction of less than 40.3 mul) was used for the evaluation of the retraction determined using the mechanical method; the presence/absence of test microorganisms in DUWLs upstream the turbine after the test was used for evaluating the microbiological assay. Results. Both evaluation methods indicated correct amounts of retraction and prevention of DUWL contamination occurred in only two cases (3.7%). Correct retraction was noted in six other dental units (DUs), but their DUWLs became contaminated during testing. Six other produced the opposite results-improper retraction, yet no contamination. The remaining 40 DUs (74.0%) failed both evaluations. Conclusion. The results showed that the overwhelming majority of the anti-retraction devices did not prevent retraction when the turbine stopped running, leading to a contamination of the water lines, and to a consequent possible cross-contamination of the patients. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 25 条
  • [21] Investigation of Cold Atmospheric Plasma-Activated Water for the Dental Unit Waterline System Contamination and Safety Evaluation in Vitro
    Pan, J.
    Li, Y. L.
    Liu, C. M.
    Tian, Y.
    Yu, S.
    Wang, K. L.
    Zhang, J.
    Fang, J.
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2017, 37 (04) : 1091 - 1103
  • [22] Long-lasting renewable antibacterial N-halamine coating enable dental unit waterlines to prevention and control of contamination of dental treatment water
    Xing, Min
    Zhang, Haifeng
    Li, Zhiyao
    Zhang, Ling
    Qian, Wenhao
    FRONTIERS IN MATERIALS, 2024, 11
  • [23] Evaluation of Antimicrobial-Antibiofilm Activity of a Hydrogen Peroxide Decontaminating System Used in Dental Unit Water Lines
    Orru, Germano
    Del Nero, Susanna
    Tuveri, Enrica
    Ciusa, Maria Laura
    Pilia, Francesca
    Erriu, Matteo
    Orru, Ginevra
    Liciardi, Manuele
    Piras, Vincenzo
    Denotti, Gloria
    OPEN DENTISTRY JOURNAL, 2010, 4 : 140 - 146
  • [24] Dual-responsive and renewable antimicrobial surfaces via catechol-based adhesion for dental unit water lines
    Liu, Wei
    Mao, Shihua
    Xu, Yuedan
    Jin, Xinyang
    Sun, Yi
    Pan, Xinni
    Fu, Baiping
    Zhang, Ling
    SURFACES AND INTERFACES, 2025, 61
  • [25] EVALUATION AND USE OF A LOW NUTRIENT MEDIUM AND REDUCED INCUBATION-TEMPERATURE TO STUDY BACTERIAL-CONTAMINATION IN THE WATER-SUPPLY OF DENTAL UNITS
    WILLIAMS, HN
    QUINBY, H
    ROMBERG, E
    CANADIAN JOURNAL OF MICROBIOLOGY, 1994, 40 (02) : 127 - 131