Efficacy of anti-retraction devices in preventing bacterial contamination of dental unit water lines

被引:31
|
作者
Berlutti, F
Testarelli, L
Vaia, F
De Luca, M
Dolci, G
机构
[1] Univ Roma La Sapienza, Dipartimento Sci Sanita Pubbl, Sez Microbiol, I-00185 Rome, Italy
[2] Univ Roma La Sapienza, Ist Clin Odontoiatr, I-00166 Rome, Italy
关键词
anti-retraction valves; bacterial contamination; dental unit water lines;
D O I
10.1016/S0300-5712(03)00004-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. In this study we examine the efficacy of anti-retraction devices in preventing microbial contamination of dental unit water lines (DUWLs). Methods. The study was performed on 54 randomly selected DUs in use at private and public institutions for over six months. The selected DUs were all currently commercially available. To evaluate the efficiency of anti-retraction devices, two different methods were employed, mechanical and microbiological. The ADA/ANSI specification #47 (corresponding to a water retraction of less than 40.3 mul) was used for the evaluation of the retraction determined using the mechanical method; the presence/absence of test microorganisms in DUWLs upstream the turbine after the test was used for evaluating the microbiological assay. Results. Both evaluation methods indicated correct amounts of retraction and prevention of DUWL contamination occurred in only two cases (3.7%). Correct retraction was noted in six other dental units (DUs), but their DUWLs became contaminated during testing. Six other produced the opposite results-improper retraction, yet no contamination. The remaining 40 DUs (74.0%) failed both evaluations. Conclusion. The results showed that the overwhelming majority of the anti-retraction devices did not prevent retraction when the turbine stopped running, leading to a contamination of the water lines, and to a consequent possible cross-contamination of the patients. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 25 条
  • [11] Assessment of nosocomial bacterial contamination in dental unit waterlines: Impact of flushing
    Alkhulaifi, Manal M.
    Alotaibi, Dalal H.
    Alajlan, Hisham
    Binshoail, Thekra
    SAUDI DENTAL JOURNAL, 2020, 32 (02) : 68 - 73
  • [12] Different Disinfection Strategies in Bacterial and Biofilm Contamination on Dental Unit Waterlines: A Systematic Review
    Li, Chuang
    Xin, Weini
    INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2025,
  • [13] Control of microbial contamination in dental unit waterlines: Effectiveness of neutral electrolytic water
    Mishima, Sayaka
    Watanabe, Takuma
    Fukuhara, Shizuko
    Ymanaka, Shigeki
    Nakao, Kazumasa
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (03) : 512 - 517
  • [14] Contamination of dental unit water lines (DUWL) with Legionella pneumophila and Pseudomonas aeruginosa; A Middle East systematic review and meta-analysis
    Khajezadeh, Masoud
    Mohseni, Fatemeh
    Khaledi, Azad
    Firoozeh, Arezoo
    EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2022, 12 (04): : 93 - 99
  • [15] An audit improves the quality of water within the dental unit water lines of general dental practices across the East of England
    Chate, R. A. C.
    BRITISH DENTAL JOURNAL, 2010, 209 (07) : 354 - 355
  • [16] Bacteriostatic effects of nanometer silver disinfectant on the biofilms in dental unit water lines
    Cheng, Lujin
    Naibijiang, Nijiatijiang
    Hasenbai, Aletengguli
    Dong, Hongbin
    He, Huiyu
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (01) : 327 - 332
  • [17] Efficacy of a Low Dose of Hydrogen Peroxide (Peroxy Ag+) for Continuous Treatment of Dental Unit Water Lines: Challenge Test with Legionella pneumophila Serogroup 1 in a Simulated Dental Unit Waterline
    Ditommaso, Savina
    Giacomuzzi, Monica
    Ricciardi, Elisa
    Zotti, Carla M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2016, 13 (07):
  • [18] Control of microbial contamination in dental unit water systems using tetra-sodium EDTA
    Percival, R. S.
    Devine, D. A.
    Nattress, B.
    Kite, P.
    Marsh, P. D.
    JOURNAL OF APPLIED MICROBIOLOGY, 2009, 107 (04) : 1081 - 1088
  • [19] Water cleaning systems improves the water quality in dental unit water lines (DUWL). A report from the Public Dental Health of Vastra Gotaland region, Sweden
    Dahlen, Gunnar
    Hjort, Gunilla
    Spencer, Inger
    SWEDISH DENTAL JOURNAL, 2013, 37 (04) : 171 - 178
  • [20] Three key factors influencing the bacterial contamination of dental unit waterlines: a 6-year survey from 2012 to 2017
    Ji, Xue-Yue
    Fei, Chun-Nan
    Zhang, Ying
    Liu, Jun
    Liu, He
    Song, Jia
    INTERNATIONAL DENTAL JOURNAL, 2019, 69 (03) : 192 - 199