Magnesium/silicon atomic weight percent ratio standards for the tissue identification of talc by scanning electron microscopy and energy dispersive X-ray analysis

被引:3
作者
McDonald, Sandra A. [1 ]
Fan, Yuwei [1 ,2 ,3 ]
Rogers, Rick A. [4 ,5 ]
Godleski, John J. [1 ,5 ,6 ]
机构
[1] John J Godleski MD PLLC, Milton, MA USA
[2] Harvard TH Chan Sch Publ Hlth, Dept Environm Hlth, Electron Microscopy Lab, Boston, MA USA
[3] Boston Univ, Sch Dent Med, Boston, MA 02215 USA
[4] Rogers Imaging Corp, Natick, MA USA
[5] Harvard TH Chan Sch Publ Hlth, Dept Environm Hlth, Boston, MA USA
[6] Harvard Med Sch, Pathol Emeritus, Boston, MA 02115 USA
关键词
Phrases; talc; scanning electron microscopy; energy dispersive X-ray spectroscopy; diagnosis; pathology; OVARIAN-CANCER; POWDER USE; EXPOSURE; ASSOCIATION; RISK;
D O I
10.1080/01913123.2019.1692119
中图分类号
TH742 [显微镜];
学科分类号
摘要
Talc may lodge in human tissues through various routes, and has been associated with the development of ovarian carcinoma in case control epidemiologic studies. Talc is detected in tissues with scanning electron microscopy and energy dispersive X-ray analysis (SEM/EDS), with expected magnesium (Mg) and silicon (Si) peaks. The theoretical atomic weight % Mg/Si ratio for talc is 0.649, and for diagnostic purposes, a range of +/- 5% (similar to 0.617 to 0.681) is often used as a standard. Our goal was to establish empirically the quantitative range for talc identification by SEM/EDS using two source materials: a Johnson's Baby Powder (cosmetic-grade) consumer sample, and talc from Sigma-Aldrich (particle-grade material intended for scientific use). We examined 401 Mg-Si particles with SEM/EDS across the two samples, using two different SEM microscopes. Overall, we found a mean Mg/Si atomic weight % ratio of 0.645, with minimal differences between study subsets. The standard deviation was 0.025; (+/- 1 sigma = 0.620-0.670). The currently used +/- 5% diagnostic range (Mg/Si 0.617-0.681) is thus reasonably close to this study's +/- 1 sigma range, and well within a +/- 2 sigma confidence interval span (Mg/Si 0.595-0.695). The +/- 5% range is thus an appropriately conservative standard whose continued use seems justified.
引用
收藏
页码:248 / 260
页数:13
相关论文
共 38 条
  • [11] Cramer DW, 1999, INT J CANCER, V81, P351, DOI 10.1002/(SICI)1097-0215(19990505)81:3<351::AID-IJC7>3.3.CO
  • [12] 2-D
  • [13] CZYZEWSKI Z, 1989, J MICROSC-OXFORD, V156, P285, DOI 10.1111/j.1365-2818.1989.tb02930.x
  • [14] A study on uterine lymphatic anatomy for standardization of pelvic sentinel lymph node detection in endometrial cancer
    Geppert, Barbara
    Lonnerfors, Celine
    Bollino, Michele
    Arechvo, Anastasija
    Persson, Jan
    [J]. GYNECOLOGIC ONCOLOGY, 2017, 145 (02) : 256 - 261
  • [15] Goldstein J.I., 2018, SEM Microscopy and X-Ray Microanalysis, pVII
  • [16] Goldstein J.I., 2018, SCANNING ELECT MICRO, P1, DOI DOI 10.1007/978-1-4939-6676-9
  • [17] Goldstein JI, 2018, SCANNING ELECT MICRO, P16
  • [18] IARC (International Agency for Research on Cancer), 2010, MONOGRAPH, V93-8C, P277, DOI [10.1603/ec09292, DOI 10.1603/EC09292]
  • [19] IARC Working Group on the Evaluation of Carcinogenic Risks to Humans, 2012, IARC Monogr Eval Carcinog Risks Hum, V100, P11
  • [20] Johnson KE, ANAL COMP TALC UNPUB