Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation

被引:48
作者
Beukema, Rypko P. [1 ]
Beukema, Willem P. [1 ]
Smit, Jaap Jan J. [1 ]
Misier, Anand R. Ramdat [1 ]
Delnoij, Peter Paul H. M. [1 ]
Wellens, Hein [1 ]
Elvan, Arif [1 ]
机构
[1] Isala Klin, Dept Cardiol, NL-8011 JW Zwolle, Netherlands
来源
EUROPACE | 2010年 / 12卷 / 04期
关键词
Atrial fibrillation; Multi-electrode ablation; Pulmonary vein isolation; CATHETER;
D O I
10.1093/europace/euq023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim A novel multi-electrode pulmonary vein ablation catheter (PVAC) combining circular mapping and duty-cycled multi-electrode radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). The aim of this study was to assess the efficacy of multi-electrode RF ablation using the PVAC device. Methods and results A total of 102 consecutive patients, age 57.9 +/- 9.6 years, with paroxysmal or persistent drug refractory atrial fibrillation (AF) were referred for ablation. All patients had documented AF episodes with an AF duration of 9.3 +/- 7.5 years (range 1.5-25). The mean total procedure time was 139.30 +/- 37.72 (median 135, range 115-172). The mean fluoroscopy time required for PVAC ablation was 17 +/- 12 min (median 16, range 12-33) and the total fluoroscopy time was 32.1 +/- 11.3 min (median 29, range 25-39). The mean multi-electrode RF ablation time required to achieve complete PV isolation was 31 +/- 6.7 min (range 16-51). In eight patients with persistent AF, additional ablations were performed to defragment septal and posterior part of the left atrium. In five patients additional RF ablations using conventional catheters were necessary. After multi-electrode duty-cycled RF ablation, 62 of 102 (60.8%) patients were in sustained sinus rhythm without anti-arrhythmic drugs. The mean follow-up duration was 12.2 +/- 3.9 months (range 6-15). Conclusion This novel multi-electrode ablation technique can be used for PV isolation and left atrium ablation with a relatively low medium-term success rate after the first ablation of similar to 61%. Larger studies with longer follow-up are required to evaluate the efficacy and whether multi-electrode RF ablation is associated with a different complication rate compared with standard PV isolation.
引用
收藏
页码:502 / 507
页数:6
相关论文
共 18 条
  • [1] Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? -: Results from a prospective randomized study
    Arentz, Thomas
    Weber, Reinhold
    Buerkle, Gerd
    Herrera, Claudia
    Blum, Thomas
    Stockinger, Jochem
    Minners, Jan
    Neumann, Franz Josef
    Kalusche, Dietrich
    [J]. CIRCULATION, 2007, 115 (24) : 3057 - 3063
  • [2] Beukema Rypko, 2009, Interact Cardiovasc Thorac Surg, V9, P956, DOI 10.1510/icvts.2009.209759
  • [3] Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter
    Boersma, Lucas V. A.
    Wijffets, Maurits C. E. F.
    Oral, Hakan
    Wever, Eric F. D.
    Morady, Fred
    [J]. HEART RHYTHM, 2008, 5 (12) : 1635 - 1642
  • [4] HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up
    Calkins, Hugh
    Brugada, Josep
    Packer, Douglas L.
    Cappato, Riccardo
    Chen, Shih-Ann
    Crijns, Harry J. G.
    Damiano, Ralph J., Jr.
    Davies, D. Wyn
    Haines, David E.
    Haissaguerre, Michel
    Iesaka, Yoshito
    Jackman, Warren
    Jais, Pierre
    Kottkamp, Hans
    Kuck, Karl Heinz
    Lindsay, Bruce D.
    Marchlinski, Francis E.
    McCarthy, Patrick M.
    Mont, J. Lluis
    Morady, Fred
    Nademanee, Koontawee
    Natale, Andrea
    Pappone, Carlo
    Prystowsky, Eric
    Raviele, Antonio
    Ruskin, Jeremy N.
    Shemin, Richard J.
    [J]. HEART RHYTHM, 2007, 4 (06) : 816 - 861
  • [5] The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study
    Chun, Kyoung-Ryul Julian
    Schmidt, Boris
    Metzner, Andreas
    Tilz, Roland
    Zerm, Thomas
    Koester, Ilka
    Fuernkranz, Alexander
    Koektuerk, Buelent
    Konstantinidou, Melanie
    Antz, Matthias
    Ouyang, Feifan
    Kuck, Karl Heinz
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 (06) : 699 - 709
  • [6] Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Takahashi, A
    Hocini, M
    Quiniou, G
    Garrigue, S
    Le Mouroux, A
    Le Métayer, P
    Clémenty, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) : 659 - 666
  • [7] Catheter Ablation Versus Antiarrhythmic Drugs for Atrial Fibrillation The A4 Study
    Jais, Pierre
    Cauchemez, Bruno
    Macle, Laurent
    Daoud, Emile
    Khairy, Paul
    Subbiah, Rajesh
    Hocini, Meleze
    Extramiana, Fabrice
    Sacher, Frederic
    Bordachar, Pierre
    Klein, George
    Weerasooriya, Rukshen
    Clementy, Jacques
    Haissaguerre, Michel
    [J]. CIRCULATION, 2008, 118 (24) : 2498 - 2505
  • [8] Specific linear left atrial lesions in atrial fibrillation - Intraoperative radiofrequency ablation using minimally invasive surgical techniques
    Kottkamp, H
    Hindricks, G
    Autschbach, R
    Krauss, B
    Strasser, B
    Schirdewahn, P
    Fabricius, A
    Schuler, G
    Mohr, FW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) : 475 - 480
  • [9] Initial experience with the Mesh catheter for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Mansour, Moussa
    Forleo, Giovanni B.
    Pappalardo, Augusto
    Heist, E. Kevin
    Avella, Andrea
    Laurenzi, Francesco
    De Girolamo, Piergiuseppe
    Bencardino, Gianluigi
    Dello Russo, Antonio
    Mantica, Massimo
    Ruskin, Jeremy N.
    Tondo, Claudio
    [J]. HEART RHYTHM, 2008, 5 (11) : 1510 - 1516
  • [10] First Experiences for Pulmonary Vein Isolation with the High-Density Mesh Ablator (HDMA): A Novel Mesh Electrode Catheter for Both Mapping and Radiofrequency Delivery in a Single Unit
    Meissner, Axel
    Plehn, Gunnar
    Van Bracht, Marc
    Schrage, Max Olav
    Christ, Martin
    Maagh, Petra
    Butz, Thomas
    Borchard, Rolf
    Trappe, Hans-Joachim
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (04) : 359 - 366