Flow Cytometric Analysis of Red Blood Cell Osmotic Fragility

被引:19
|
作者
Yamamoto, Ayako [1 ]
Saito, Norihiro [1 ]
Yamauchi, Yumiko [2 ]
Takeda, Masahide [2 ]
Ueki, Shigeharu [2 ]
Itoga, Masamichi [1 ]
Kojima, Keiya [1 ]
Kayaba, Hiroyuki [1 ]
机构
[1] Hirosaki Univ, Grad Sch Med, Dept Clin Lab Med, Hirosaki, Aomori 0368562, Japan
[2] Akita Univ, Grad Sch Med, Dept Gen Med Practice & Lab Diagnost Med, Akita 010, Japan
来源
JALA | 2014年 / 19卷 / 05期
关键词
erythrocyte; osmotic fragility; flow cytometry; hemolytic anemia;
D O I
10.1177/2211068214532254
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study investigated a new method of flow cytometry (FCM) for analysis of red blood cell (RBC) osmotic fragility. Venous peripheral blood collected in a sampling tube coated with EDTA 2Na was analyzed using FCM to determine RBC osmotic fragility. RBCs were represented as a double-peaked forward scatter (FSC) histogram in FCM. RBCs showed ballooning and spherical shape change in hypotonic solutions before hemolysis. The ballooning of RBCs was expressed as a disappearance of the minor peak and by narrowing and a shift to the right of the FSC histogram. The process of hemolysis was expressed as shrinking of the RBC cytogram in the right upper quadrant on the scatter plot of side scatter versus FSC and by emergence of a cell debris cytogram in the left lower quadrant. The ratio of intact RBCs in hypotonic solution was available as an indicator of osmotic fragility. Acidic solution made erythrocytes less tolerant to hypotonic solution by inducing spherical shape change. In conclusion, FCM can be used to assess RBC osmotic fragility.
引用
收藏
页码:483 / 487
页数:5
相关论文
共 50 条
  • [1] Flow Cytometric Osmotic Fragility-An Effective Screening Approach for Red Cell Membranopathies
    Warang, Prashant
    Gupta, Maya
    Kedar, Prabhakar
    Ghosh, Kanjaksha
    Colah, Roshan
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2011, 80B (03) : 186 - 190
  • [3] Flow Cytometric Detection of Erythrocyte Osmotic Fragility
    Won, Dong Il
    Suh, Jang Soo
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (02) : 135 - 141
  • [4] Red blood cell osmotic fragility in chronically hemodialyzed patients
    Wu, SG
    Jeng, FR
    Wei, SY
    Su, CZ
    Chung, TC
    Chang, WJ
    Chang, HW
    NEPHRON, 1998, 78 (01): : 28 - 32
  • [5] Flow Cytometric Analysis Of Red Blood Cell Dysfunction In Septic Patients
    Tsang, G.
    Wexler, O.
    Wojciechowski, W.
    Falkner, K.
    Mroczek, S.
    Oldfield, D.
    Maddock, B.
    Apostolakos, M.
    Pietropaoli, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [6] Effect of zinc supplementation on red blood cell osmotic fragility in hemodialysis
    Dorche, Sharifian M.
    Roozbeh, Jamshid
    Karimi, Mehran
    Jahromi, Alireza Hamidian
    Afshariani, Raha
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2009, 14 : 149 - 149
  • [7] Red blood cell osmotic fragility in Bufo arenarum exposed to lead
    Rosenberg, CE
    Peri, SI
    Arrieta, MA
    Fink, NE
    Salibian, A
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1998, 106 (01) : 19 - 24
  • [8] THE FLOW CYTOMETRIC OSMOTIC FRAGILITY TEST IS AN EFFECTIVE SCREENING TEST FOR RED CELL MEMBRANE DISORDERS INCLUDING DEHYDRATED HEREDITARY STOMATOCYTOSIS
    Iwasaki, Takuya
    Utsugisawa, Taiju
    Ogura, Hiromi
    Aoki, Takako
    Kinoshita, Akemi
    Ogata, Yasutaka
    Okamoto, Yoshio
    Kawakami, Takahiro
    Kanno, Hitoshi
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 47 - 47
  • [9] FLOW CYTOMETRIC OSMOTIC FRAGILITY (FC-OF) CAN REPLACE THE TRADITIONAL OSMOTIC FRAGILITY (OF) TEST? PRELIMINARY RESULTS
    Crisp, R.
    Solari, L.
    Gammela, D.
    Schvartzman, G.
    Alfonso, G.
    Donato, H.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2010, 95 : 702 - 703
  • [10] Red blood cell osmotic fragility in healthy loggerhead and green sea turtles
    Radisic, Rebecca
    Owens, Sean D.
    Manire, Charles A.
    Montgomery, Nicole
    Mader, Doug
    Zirkelbach, Bette
    Stacy, Nicole I.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2020, 32 (06) : 908 - 911