Electron beam dose calculation: Hybrid pencil beam model extended for small fields

被引:0
作者
Gou, CJ
Zeng, G
Luo, ZM [1 ]
机构
[1] Sichuan Univ, Educ Minist China, Key Lab Radiat Phys & Technol, Chengdu 610064, Peoples R China
[2] Sichuan Univ, Inst Nucl Sci & Technol, Chengdu 610064, Peoples R China
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The hybrid electron pencil beam model (HPBM) can usually be applied to middle or large fields and get good results, whereas it is sometimes not so successful to apply HPBM to small fields. In this note we report some results obtained by using an extended hybrid electron pencil beam model for small fields. Considering the condition of small fields, we redefine the central-axis depth dose for mono-energetic electrons in small fields and calculate the fitted spectrum of incident electron beam for these small fields. Through these improvements, we can make the extended hybrid electron pencil beam model applicable to small fields and obtain good results. And at the same time, the extended HPBM retains the calculation accuracy and efficiency for middle and large fields.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 50 条
[41]   Evaluation of a Modified Pencil Beam Algorithm Dose Calculation in the Presence of Intensity Modulators for Intensity Modulated Bolus Electron Beam Conformal Therapy [J].
Hilliard, E. ;
Carver, R. ;
Hogstrom, K. ;
Erhart, K. .
MEDICAL PHYSICS, 2019, 46 (06) :E230-E231
[42]   Polar Coordinate Based Pencil Beam Dose Calculation Algorithm for VMAT [J].
Tseng, W. ;
Lu, B. .
MEDICAL PHYSICS, 2021, 48 (06)
[43]   A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm [J].
Ding, GX ;
Cygler, JE ;
Yu, CW ;
Kalach, NI ;
Daskalov, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02) :622-633
[44]   A MULTIRAY MODEL FOR CALCULATING ELECTRON PENCIL BEAM DISTRIBUTION [J].
YU, CX ;
GE, WS ;
WONG, JW .
MEDICAL PHYSICS, 1988, 15 (05) :662-671
[45]   Evaluation of a Beam Model Applicable to Small Fields in TomoTherapy Delivered Dose [J].
Caprile, P. ;
Hartmann, G. H. .
MEDICAL PHYSICS, 2009, 36 (06)
[46]   DESCRIPTION OF THE UNCOLLIMATED ELECTRON-BEAM IN AIR BY MEANS OF A DIRECTIONAL PENCIL BEAM MODEL [J].
POLMAN, HLA ;
VANDERLINDEN, PM .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (03) :355-363
[47]   USING BACKGROUND SUBTRACTION FOR MEASURING THE DOSE DISTRIBUTION OF AN ELECTRON PENCIL BEAM [J].
MCPARLAND, BJ .
MEDICAL PHYSICS, 1987, 14 (03) :406-409
[48]   Use of pencil-beam redefinition algorithm for electron are dose calculations [J].
Chi, P ;
Boyd, R ;
Hogstrom, K .
MEDICAL PHYSICS, 2003, 30 (06) :1518-1518
[49]   Calculation of the entrance skin dose distribution for fluoroscopically guided interventions using a pencil beam backscatter model [J].
Vijayan, Sarath ;
Xiong, Zhenyu ;
Rudin, Stephen ;
Bednarek, Daniel R. .
Journal of Medical Imaging, 2017, 4 (03)
[50]   Refinements of the finite-size pencil beam model of three-dimensional photon dose calculation [J].
Ostapiak, OZ ;
Zhu, Y ;
VanDyk, J .
MEDICAL PHYSICS, 1997, 24 (05) :743-750