Gyroscopes have been proposed as sensors for ambulatory gait analysis and functional electrical stimulation systems. Accurate determination of the Initial Contact of the foot with the floor (IC) and the final contact or Foot Off (FO) on different terrains is important. This paper describes the evaluation of a gyroscope placed on the shank for determination of IC and FO in subjects walking outdoors on level ground, and up and down an incline. Performance was compared with a reference pressure measurement system. The mean difference between the gyroscope and the reference was less than -25 ms for IC and less than 75 ms for FO for all terrains. Detection success was over 98%. These results provide preliminary evidence supporting the use of the gyroscope for gait event detection on inclines as well as level walking.
引用
收藏
页码:5683 / 5702
页数:20
相关论文
共 51 条
  • [1] A kinematic comparison of overground and treadmill walking
    Alton, F
    Baldey, L
    Caplan, S
    Morrissey, MC
    [J]. CLINICAL BIOMECHANICS, 1998, 13 (06) : 434 - 440
  • [2] Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement
    Aminian, K
    Trevisan, C
    Najafi, B
    Dejnabadi, H
    Frigo, C
    Pavan, E
    Telonio, A
    Cerati, F
    Marinoni, EC
    Robert, P
    Leyvraz, PF
    [J]. GAIT & POSTURE, 2004, 20 (01) : 102 - 107
  • [3] Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
    Aminian, K
    Najafi, B
    Büla, C
    Leyvraz, PF
    Robert, P
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (05) : 689 - 699
  • [4] Detection of gait events using an F-Scan in-shoe pressure measurement system
    Catalfamo, Paola
    Moser, David
    Ghoussayni, Salim
    Ewins, David
    [J]. GAIT & POSTURE, 2008, 28 (03) : 420 - 426
  • [5] Dai R, 1996, IEEE Trans Rehabil Eng, V4, P63, DOI 10.1109/86.506403
  • [6] Foot contact event detection using kinematic data in cerebral palsy children and normal adults gait
    Desailly, Eric
    Daniel, Yepremian
    Sardain, Philippe
    Lacouture, Patrick
    [J]. GAIT & POSTURE, 2009, 29 (01) : 76 - 80
  • [7] Predicting lower limb joint kinematics using wearable motion sensors
    Findlow, A.
    Goulermas, J. Y.
    Nester, C.
    Howard, D.
    Kenney, L. P. J.
    [J]. GAIT & POSTURE, 2008, 28 (01) : 120 - 126
  • [8] Assessment and validation of a simple automated method for the detection of gait events and intervals
    Ghoussayni, S
    Stevens, C
    Durham, S
    Ewins, D
    [J]. GAIT & POSTURE, 2004, 20 (03) : 266 - 272
  • [9] Ghoussayni S., 2004, THESIS U SURREY GUIL
  • [10] Ghoussayni S. N., 2001, P 7 VIENN INT WORKSH, P200