Gas sensors based on piezoelectric micro-diaphragm transducer

被引:2
作者
Shin, S
Paik, JK
Lee, NE
Park, HD
Park, JS
Lee, J
机构
[1] Sungkyunkwan Univ, Dept Mat Sci & Engn, Suwon 440746, South Korea
[2] Korea Elect Technol Inst, Pyongtaek 451865, South Korea
关键词
gas sensor; PZT; micro-diaphragm; resonant frequency; MEMS; CANTILEVER ARRAY; FREQUENCY;
D O I
10.1080/10584580590899298
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have fabricated high sensitive gas sensor based on piezoelectrically driven micro-diaphragm transducers. The micro-diaphragm transducer was fabricated using micro-electro-mechanical-system (MEMS) technique. The diol based sol-gel derived Pb(Zr-0.52,Ti-0.48)O-3(PZT) film was used as a piezoelectric actuating layer. We have used the resonant frequency change of micro-diaphragm transducer upon mass increase as a sensing signal. The resonant frequency values were measured by analysis of electrical signals from the micro-diaphragm transducer. The fundamental resonant frequency of the micro-diaphragm was in the range of 250 to 360 kHz, depending on their physical boundary conditions. The mass sensitivity of bare micro-diaphragm transducer was 66.5 Hz/ng. Two polymer sensing layers such as the polymethylmethacrylate (PMMA) and polydimethylsiloxane (PDMS) films were used to estimate the gas sensing behavior of microtransducers for various vapors of organic compounds. PMMA was used to detect primary alcohols while PDMS was used for toluene and benzene. The resonant frequency of micro-diaphragm transducer was shifted toward lower frequency range as the vapor concentration increased. With PMMA gas sensing layer, the micro-diaphragm showed a gas sensitivity of 0.456 Hz/ppm for ethanol vapor. When the PDMS gas sensing layer was used, the micro-diaphragm showed a gas sensitivity of 0. 143 Hz/ppm for toluene vapor. When the test vapors were removed from the reaction chamber, the resonant frequencies of micro-diaphragm sensors were completely recovered to their initial state.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 7 条
[1]   The electronic nose applied to dairy products: a review [J].
Ampuero, S ;
Bosset, JO .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 94 (01) :1-12
[2]   A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout [J].
Battiston, FM ;
Ramseyer, JP ;
Lang, HP ;
Baller, MK ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Güntherodt, HJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :122-131
[3]  
Grate JayW., 1996, SENSORS UPDATE, V2, P37
[4]   Frequency encoding of resonant mass sensors for chemical vapor detection [J].
Guan, SH .
ANALYTICAL CHEMISTRY, 2003, 75 (17) :4551-4557
[5]   Multicomponent analysis and prediction with a cantilever array based gas sensor [J].
Kim, BH ;
Prins, FE ;
Kern, DP ;
Raible, S ;
Weimar, U .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :12-18
[6]   Self-excited piezoelectric cantilever oscillators [J].
Lee, SS ;
White, RM .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 52 (1-3) :41-45
[7]   Fabrication and sensing behavior of piezoelectric microcantilever for nanobalance [J].
Shin, S ;
Song, S ;
Lee, Y ;
Lee, N ;
Park, J ;
Park, H ;
Lee, J .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2003, 42 (9B) :6139-6142