Bioelectrical impedance analysis -: part II:: utilization in clinical practice

被引:1548
作者
Kyle, UG
Bosaeus, I
De Lorenzo, AD
Deurenberg, P
Elia, M
Gómez, JM
Heitmann, BL
Kent-Smith, L
Melchior, JC
Pirlich, M
Scharfetter, H
Schols, AMWJ
Pichard, C [1 ]
机构
[1] Univ Hosp Geneva, Clin Nutr Unit, CH-1211 Geneva 14, Switzerland
[2] Sahlgrens Univ Hosp, S-41345 Gothenburg, Sweden
[3] Univ Roma Tor Vergata, I-00173 Rome, Italy
[4] Southampton Gen Hosp, Southampton SO9 4XY, Hants, England
[5] Hosp Univ Bellvitge, Barcelona, Spain
[6] Univ Copenhagen Hosp, DK-2100 Copenhagen, Denmark
[7] Univ Porto, P-4100 Oporto, Portugal
[8] Hop Raymond Poincare, Garches, France
[9] Univ Klinikum Charite, Berlin, Germany
[10] Graz Univ Technol, A-8010 Graz, Austria
[11] Univ Hosp Maastricht, Maastricht, Netherlands
关键词
bioelectrical impedance analysis; BIA; segmental bioelectrical impedance analysis;
D O I
10.1016/j.clnu.2004.09.012
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
BIA is easy, non-invasive, relatively inexpensive and can be performed in almost any subject because it is portable. Part II of these ESPEN guidelines reports results for fat-free mass (FFM), body fat (BF), body cell mass (BCM), total body water (TBW), extracellular water (ECW) and intracellular water (ICW) from various studies in healthy and ill subjects. The data suggests that BIA works well in healthy subjects and in patients with stable water and electrolytes balance with a validated BIA equation that is appropriate with regard to age, sex and race. Clinical use of BIA in subjects at extremes of BMI ranges or with abnormal hydration cannot be recommended for routine assessment of patients until further validation has proven for BIA algorithm to be accurate in such conditions. Mutli-frequency and segmental-BIA may have advantages over single-frequency BIA in these conditions, but further validation is necessary. Longitudinal follow-up of body composition by BIA is possible in subjects with BMI 16-34 kg/m(2) without abnormal hydration, but must be interpreted with caution. Further validation of BIA is necessary to understand the mechanisms for the changes observed in acute illness, altered fat/lean mass ratios, extreme heights and body shape abnormalities. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1430 / 1453
页数:24
相关论文
共 129 条
  • [1] Body-water compartments measured by bio-electrical impedance spectroscopy in patients with chronic obstructive pulmonary disease
    Baarends, EM
    Lichtenbelt, WDV
    Wouters, EFM
    Schols, AMWJ
    [J]. CLINICAL NUTRITION, 1998, 17 (01) : 15 - 22
  • [2] BODY-COMPOSITION IN ELDERLY PEOPLE - EFFECT OF CRITERION ESTIMATES ON PREDICTIVE EQUATIONS
    BAUMGARTNER, RN
    HEYMSFIELD, SB
    LICHTMAN, S
    WANG, J
    PIERSON, RN
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1991, 53 (06) : 1345 - 1353
  • [3] Comparison of bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of appendicular body composition in anorexic women
    Bedogni, G
    Marra, M
    Bianchi, L
    Malavolti, M
    Nicolai, E
    De Filippo, E
    Scalfi, L
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2003, 57 (09) : 1068 - 1072
  • [4] Multifrequency bioelectric impedance measurements for predicting body water compartments in Duchenne muscular dystrophy
    Bedogni, G
    Merlini, L
    Ballestrazzi, A
    Severi, S
    Battistini, N
    [J]. NEUROMUSCULAR DISORDERS, 1996, 6 (01) : 55 - 60
  • [5] Bellizzi V., 1998, Journal of the American Society of Nephrology, V9, p140A
  • [6] Bioelectrical impedance analysis during acute changes of extracellular osmolality in man
    Berneis, K
    Keller, U
    [J]. CLINICAL NUTRITION, 2000, 19 (05) : 361 - 366
  • [7] BESHYAH SA, 1995, AM J CLIN NUTR, V61, P1186
  • [8] Birmingham CL, 1996, INT J EAT DISORDER, V19, P311, DOI 10.1002/(SICI)1098-108X(199604)19:3&lt
  • [9] 311::AID-EAT10&gt
  • [10] 3.0.CO