Failure Criterion of Ordinary Concrete Subjected to Triaxial Compression of Full Section and Local Loadings

被引:19
作者
Yu, Zhenpeng [1 ]
Huang, Qiao [1 ]
Shan, Yushi [1 ]
Ren, Zheng [1 ]
机构
[1] Southeast Univ, Sch Transportat, Nanjing 210096, Jiangsu, Peoples R China
基金
美国国家科学基金会;
关键词
Failure criterion; Local loading; Ordinary concrete; True triaxial compression; Residual mechanical properties; DAM CONCRETE; BEHAVIOR; STRENGTH;
D O I
10.1061/(ASCE)MT.1943-5533.0002399
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, experiments carried out on ordinary concrete under multiaxial compression of both full section and local section are presented and the failure modes compared under different loading conditions. According to the stress-strain curves obtained in true triaxial compression experiments, the mechanical properties of ordinary concrete were also extracted under different loading conditions, including full section loading and local loading. Because of the confining pressure, as for full section loading, the peak stresses under multiaxial compression were 1.27-2.27 times higher than those under uniaxial compression, whereas for local loading, the multiple was 1.24-2.05 times. It is obvious that the increasing coefficients under full section compression are more susceptible to confining pressures than those under local compression. The unique point of the experimental method is that ordinary concrete was subjected to full section or local uniaxial compression after full section or local triaxial compression. In this way, the failure modes of ordinary concrete were clearly revealed owing to the initial damage caused by triaxial compression. Meanwhile, the residual mechanical properties of ordinary concrete that had been subjected to full section or local triaxial compression were obtained, contributing to a comprehensive understanding of the mechanical properties of ordinary concrete under triaxial compression. Then a failure criterion of ordinary concrete under local loading was proposed based on the data of true triaxial compression experiments. The failure criterion was verified using data of both relevant scholars' experiments and independent experiments of local triaxial loading. The results showed that the proposed failure criterion was simple but effective enough to compute the failure strength of ordinary concrete.
引用
收藏
页数:13
相关论文
共 24 条
  • [1] [Anonymous], 1970, J PROC
  • [2] A unified failure envelope for hybrid fibre reinforced concrete subjected to true triaxial compression
    Chi, Yin
    Xu, Lihua
    Mei, Guodong
    Hu, Nian
    Su, Jie
    [J]. COMPOSITE STRUCTURES, 2014, 109 : 31 - 40
  • [3] Chinese National Standard, 2011, JGJ552011 CHIN NAT S
  • [4] Novel Approach to Strength Modeling of Concrete under Triaxial Compression
    Gandomi, Amir Hossein
    Babanajad, Saeed Karim
    Alavi, Amir Hossein
    Farnam, Yaghoob
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2012, 24 (09) : 1132 - 1143
  • [5] Guo Z., 1997, STRENGTH DEFORMATION, P166
  • [6] Guo Z., 2004, INTENSITY CONSTITUTI
  • [7] A critical state based constitutive model for the triaxial response of ballast incorporating particle breakage
    Indraratna, Buddhima
    Sun, Qideng
    Nimbalkar, Sanjay
    [J]. FROM FUNDAMENTALS TO APPLICATIONS IN GEOTECHNICS, 2015, : 1232 - 1239
  • [8] Kupfer H.B., 1973, Journal of Engineering Mechanics ASCE, V99, P853
  • [9] Launay P., 1971, REV BRASILEIRA EDUCA, V11, P340
  • [10] Experimental study of the mechanical behavior of plastic concrete in triaxial compression
    Mahboubi, A
    Ajorloo, A
    [J]. CEMENT AND CONCRETE RESEARCH, 2005, 35 (02) : 412 - 419