Improved nerve conspicuity with water-weighting and denoising in two-point Dixon magnetic resonance neurography

被引:4
|
作者
Tan, Ek T. [1 ]
Queler, Sophie C. [1 ]
Lin, Bin [1 ]
Endo, Yoshimi [1 ]
Burge, Alissa J. [1 ]
Sternberg, Julia [1 ]
Potter, Hollis G. [1 ]
Sneag, Darryl B. [1 ]
机构
[1] Hosp Special Surg, Dept Radiol & Imaging, 535 E 70th St, New York, NY 10021 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance neurography; Dixon; Principal component analysis; Quantitative magnetic resonance imaging; Denoising; Fat quantification; SKELETAL-MUSCLE; FAT-SUPPRESSION; IDEAL; MRI; DECOMPOSITION; SEPARATION; T-2;
D O I
10.1016/j.mri.2021.03.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: T2-weighted, two-point Dixon fast-spin-echo (FSE) is an effective technique for magnetic resonance neurography (MRN) that can provide quantitative assessment of muscle denervation. Low signal-to-noise ratio and inadequate fat suppression, however, can impede accurate interpretation. Purpose: To quantify effects of principal component analysis (PCA) denoising on tissue signal intensities and fat fraction (FF) and to determine qualitative image quality improvements from both denoising and water-weighting (WW) algorithms to improve nerve conspicuity and fat suppression. Study type: Prospective. Subjects: Twenty-one subjects undergoing MR neurography evaluation (11/10 male/female, mean age = 46.3+13.7 years) with 60 image volumes. Twelve subjects (23 image volumes) were determined to have muscle denervation based on diffusely elevated T2 signal intensity. Field strength/sequence: 3 T, 2D, two-point Dixon FSE. Assessment: Qualitative assessment included overall image quality, nerve conspicuity, fat suppression, pulsation and ringing artifacts by 3 radiologists separately on a three-point scale (1 = poor, 2 = average, 3 = excellent). Quantitative measurements for FF and signal intensity relative to normal muscle were made for nerve, abnormal muscle and subcutaneous fat. Statistical tests: Linear and ordinal regression models were used for quantitative and qualitative comparisons, respectively; 95% confidence intervals (CIs) and p-values for pairwise comparisons were adjusted using the Holm-Bonferroni method. Inter-rater agreement was assessed using Gwet's agreement coefficient (AC(2)). Results: Simulations showed PCA-denoising reduced FF error from 2.0% to 1.0%, and from 7.6% to 3.1% at noise levels of 10% and 30%, respectively. In human subjects, PCA-denoising did not change signal levels and FF quantitatively. WW decreased fat signal significantly (-83.6%, p < 0.001). Nerve conspicuity was improved by WW (odds ratio, OR = 5.8, p < 0.001). Fat suppression was improved by both PCA (OR = 3.6, p < 0.001) and WW (OR = 2.2, p < 0.001). Overall image quality was improved by PCA + WW (OR = 1.7, p = 0.04). Conclusions: WW and PCA-denoising improved nerve conspicuity and fat suppression in MR neurography. Denoising can potentially provide improved accuracy of FF maps for assessing fat-infiltrated muscle.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 18 条
  • [1] Improved T1, Contrast Concentration, and Pharmacokinetic Parameter Quantification in the Presence of Fat with Two-Point Dixon for Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Le, Yuan
    Dale, Brian
    Akisik, Fatih
    Koons, Karen
    Lin, Chen
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1677 - 1684
  • [2] Two-point Dixon fat-water swapping artifact: lesion mimicker at musculoskeletal T2-weighted MRI
    Kirchgesner, Thomas
    Acid, Souad
    Perlepe, Vasiliki
    Lecouvet, Frederic
    Vande Berg, Bruno
    SKELETAL RADIOLOGY, 2020, 49 (12) : 2081 - 2086
  • [3] Direct water and fat determination in two-point Dixon imaging with flexible echo times
    Rambow, Olen
    Hazle, John
    Clark, John
    Ma, Jingfei
    MEDICAL PHYSICS, 2013, 40 (11)
  • [4] Usefulness of two-point Dixon fat-water separation technique in gadoxetic acid-enhanced liver magnetic resonance imaging
    Ding, Ying
    Rao, Sheng-Xiang
    Chen, Cai-Zhong
    Li, Ren-Chen
    Zeng, Meng-Su
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (16) : 5017 - 5022
  • [5] Fat suppression in magnetic resonance imaging of the head and neck region: is the two-point DIXON technique superior to spectral fat suppression?
    Wendl, Christina M.
    Eiglsperger, Johannes
    Dendl, Lena-Marie
    Brodoefel, Harald
    Schebesch, Karl-Michael
    Stroszczynski, Christian
    Fellner, Claudia
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1085):
  • [6] Comparison of modified two-point dixon and chemical shift encoded MRI water-fat separation methods for fetal fat quantification
    Giza, Stephanie A.
    Miller, Michael R.
    Parthasarathy, Prasiddha
    de Vrijer, Barbra
    McKenzie, Charles A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (01) : 274 - 282
  • [7] Two-point Dixon fat-water swapping artifact: lesion mimicker at musculoskeletal T2-weighted MRI
    Thomas Kirchgesner
    Souad Acid
    Vasiliki Perlepe
    Frédéric Lecouvet
    Bruno Vande Berg
    Skeletal Radiology, 2020, 49 : 2081 - 2086
  • [8] Two-point dixon technique for water-fat signal decomposition with B-o inhomogeneity correction
    Coombs, BD
    Szumowski, J
    Coshow, W
    MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) : 884 - 889
  • [9] An automated iterative algorithm for water and fat decomposition in three-point Dixon magnetic resonance imaging
    Chen, QS
    Schneider, E
    Aghazadeh, B
    Weinhous, MS
    Humm, J
    Ballon, D
    MEDICAL PHYSICS, 1999, 26 (11) : 2341 - 2347
  • [10] Tinel sign to the median nerve area caused by a proximal tumor as detected by magnetic resonance neurography: Two case reports
    Narita, Yugo
    Fukuroku, Keiko
    Matsuyama, Hirofumi
    Ii, Yuichiro
    Maeda, Masayuki
    Tomimoto, Hidekazu
    NEUROLOGY AND CLINICAL NEUROSCIENCE, 2019, 7 (03): : 122 - 124