On-site quality control of photovoltaic modules with the PV MOBILE LAB

被引:8
|
作者
Coello, Jorge [1 ]
Perez, Leonardo [1 ]
Dominguez, Francisco [1 ]
Navarrete, Miguel [1 ]
机构
[1] Enertis Solar, SS De Los Reyes 28703, Spain
来源
2013 ISES SOLAR WORLD CONGRESS | 2014年 / 57卷
关键词
PV module; quality control; testing laboratory;
D O I
10.1016/j.egypro.2014.10.012
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the design, development and results obtained with a mobile laboratory: the PV Mobile Lab. With the development of this powerful tool, Enertis Solar is the first IEC 17025 accredited laboratory capable of performing on-site test in PV modules. The PV Mobile Lab is designed to perform the following tests: visual inspection, Peak Power determination in STC, electrical insulation, IR Thermography and electroluminescence imaging. The design of the mobile laboratory ensures the reliability of the results as if conducted in a conventional laboratory. Its innovative design based on an expandable system has allowed us to implement a solar simulator of tunnel type (illuminated area 2x2 m2 and lamp -DUT distance 5.5 m) in a vehicle that weights less than 3,500 kg. The spectral, temporal and spatial (non-uniformity) stability of the simulator remain within the parameters that define it as a class A(+)A(+)A(+) simulator. The environmental conditions during the performance of the tests are controlled and the flash incidence is normal to the module surface. Furthermore, due to the implementation of programmable switches, test sequences have been fully automated optimizing the time required for characterizing a module. The paper also presents the results obtained in the quality control of 500 modules tested during the commissioning test of 2 PV plants located in the UK. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 43 条
  • [41] Quality control recommendations for RNASeq using FFPE samples based on pre-sequencing lab metrics and post-sequencing bioinformatics metrics
    Yuanhang Liu
    Aditya Bhagwate
    Stacey J. Winham
    Melissa T. Stephens
    Brent W. Harker
    Samantha J. McDonough
    Melody L. Stallings-Mann
    Ethan P. Heinzen
    Robert A. Vierkant
    Tanya L. Hoskin
    Marlene H. Frost
    Jodi M. Carter
    Michael E. Pfrender
    Laurie Littlepage
    Derek C. Radisky
    Julie M. Cunningham
    Amy C. Degnim
    Chen Wang
    BMC Medical Genomics, 15
  • [42] Quality control recommendations for RNASeq using FFPE samples based on pre-sequencing lab metrics and post-sequencing bioinformatics metrics
    Liu, Yuanhang
    Bhagwate, Aditya
    Winham, Stacey J.
    Stephens, Melissa T.
    Harker, Brent W.
    McDonough, Samantha J.
    Stallings-Mann, Melody L.
    Heinzen, Ethan P.
    Vierkant, Robert A.
    Hoskin, Tanya L.
    Frost, Marlene H.
    Carter, Jodi M.
    Pfrender, Michael E.
    Littlepage, Laurie
    Radisky, Derek C.
    Cunningham, Julie M.
    Degnim, Amy C.
    Wang, Chen
    BMC MEDICAL GENOMICS, 2022, 15 (01)
  • [43] A Brief Update on Inter-lab Quality Control (ILQC) Activities for COVID-19 Reverse Transcription-Polymerase Chain Reaction (RTPCR) by All India Institute of Medical Sciences (AIIMS) Nagpur, India
    Shete, Vishal
    Mishra, Meena
    Gade, Neeta
    Nag, Soumyabrata
    Shendre, Pooja
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)