Central and peripheral pachymetry measurements according to age using the Pentacam rotating Scheimpflug camera

被引:112
作者
Khoramnia, Rarnin [1 ]
Rabsilber, Tanja M. [1 ]
Auffarth, Gerd U. [1 ]
机构
[1] Univ Heidelberg, Dept Ophthalmol, Int Vis Correct Res Ctr, D-69120 Heidelberg, Germany
关键词
D O I
10.1016/j.jcrs.2006.12.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the mean values and standard deviations as well as the reliability of consecutive examinations of central and peripheral corneal thickness measurements according to age using the Pentacam rotating Scheimpflug camera (Oculus, Inc.). SETTING: Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. METHODS: Seventy-six healthy volunteers were enrolled in a clinical prospective study. Three consecutive Pentacam measurements of 1 eye per subject were taken. Evaluated were the central corneal thickness (CCT), corneal thickness at 4 peripheral points (3.0 mm superior, inferior, nasal, and temporal), and the thinnest point of the cornea. The volunteers were then assigned to 3 groups to assess the influence of increasing age on the study parameters. RESULTS: The mean age of the subjects was 46.6 years +/- 16.8 (SD). The mean CCT was 539.62 +/- 31.87 mu m. Peripherally, the corneal thickness was between 11% and 19% higher than centrally, with the superior cornea being the thickest followed by the nasal, the inferior, and the temporal cornea. The thinnest point was located in the inferotemporal quadrant in 92% of eyes and in the superotemporal quadrant in 8%. There was no correlation between age and corneal thickness. Minor mean standard deviations of consecutive measurements were noted in the corneal center (4.33 mu m), increasing significantly toward the periphery (mean 8.31 mu m). Increasing age was not associated with decreasing reliability. CONCLUSIONS: Using the Pentacam, it was possible to acquire information about corneal thickness across the entire cornea. No correlation was found between increasing age and change in peripheral or CCT. Good reliability was noted for pachymetry measurements decreasing slightly toward the periphery, which was independent of age.
引用
收藏
页码:830 / 836
页数:7
相关论文
共 33 条
  • [1] Keratoconus evaluation using the Orbscan Topography System
    Auffarth, GU
    Wang, L
    Völcker, HE
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02) : 222 - 228
  • [2] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1729 - 1735
  • [3] Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    Bechmann, M
    Thiel, MJ
    Neubauer, AS
    Ullrich, S
    Ludwig, K
    Kenyon, KR
    Ulbig, MW
    [J]. CORNEA, 2001, 20 (01) : 50 - 54
  • [4] Comparison of three methods of measuring corneal thickness and anterior chamber depth
    Buehl, W
    Stojanac, D
    Sacu, S
    Drexler, W
    Findl, O
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) : 7 - 12
  • [5] Accommodative intraocular lens tilting
    Cazal, J
    Lavin-Dapena, C
    Marín, J
    Vergés, C
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 341 - 344
  • [6] Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    Doughty, MJ
    Zaman, ML
    [J]. SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) : 367 - 408
  • [7] Corneal thickness: measurement and implications
    Ehlers, N
    Hjortdal, J
    [J]. EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) : 543 - 548
  • [8] Comparison of human central cornea and limbus in vivo using optical coherence tomography
    Feng, YW
    Simpson, TL
    [J]. OPTOMETRY AND VISION SCIENCE, 2005, 82 (05) : 416 - 419
  • [9] Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    González-Méijome, JM
    Cerviño, A
    Yebra-Pimentel, E
    Parafita, MA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) : 125 - 132
  • [10] INVESTIGATIONS ON LENS TRANSPARENCY AND ITS DISTURBANCES BY MICRODENSITOMETRIC ANALYSES OF SCHEIMPFLUG PHOTOGRAPHS
    HOCKWIN, O
    LERMAN, S
    OHRLOFF, C
    [J]. CURRENT EYE RESEARCH, 1984, 3 (01) : 15 - 22