Immediate Loading of Mandibular Overdentures Supported by One-Piece, Direct Metal Laser Sintering Mini-Implants: A Short-Term Prospective Clinical Study

被引:24
作者
Mangano, Francesco G. [1 ,2 ]
Caprioglio, Alberto [1 ]
Levrini, Luca [1 ]
Farronato, Davide [1 ]
Zecca, Piero A. [1 ,2 ]
Mangano, Carlo [1 ,2 ]
机构
[1] Univ Insubria, Sch Dent, Dept Surg & Morphol Sci, Varese, Italy
[2] Univ Insubria, Innovat Technol & Engn Biomat Res Ctr, Varese, Italy
关键词
Dental implants; dental prosthesis; immediate dental implant loading; lasers; mandible; UNSPLINTED IMPLANTS; PROSPECTIVE COHORT; DENTAL IMPLANTS; BONE; RESTORATIONS; FABRICATION; SMOKERS; SURFACE; MULTICENTER; TOPOGRAPHY;
D O I
10.1902/jop.2014.140343
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Only a few studies have dealt with immediately loaded, unsplinted mini-implants supporting ball attachment-retained mandibular overdentures (ODs). The aim of this study is to evaluate treatment outcomes of ball attachment-retained mandibular ODs supported by one-piece, unsplinted, immediately loaded, direct metal laser sintering (DMLS) mini-implants. Methods: Over a 4-year period (2009 to 2012), all patients referred to the Dental Clinic, University of Varese, and to a private practice for treatment with mandibular ODs were considered for inclusion in this study. Each patient received three or four DMLS mini-implants. Immediately after implant placement, a mandibular OD was connected to the implants. At each annual follow-up session, clinical and radiographic parameters were assessed, including the following outcome measures: 1) implant failures; 2) peri-implant marginal bone loss; and 3) complications. Statistical analysis was conducted using a life-table analysis. Results: A total of 231 one-piece DMLS mini-implants were inserted in 62 patients. After 4 years of loading, six implants failed, giving an overall cumulative survival rate of 96.9%. The mean distance between the implant shoulder and the first visible bone-to-implant contact was 0.38 +/- 0.25 and 0.62 +/- 0.20 mm at the 1- and 4-year follow-up examinations, respectively. An incidence of 6.0% of biologic complications was reported; prosthetic complications were more frequent (12.9%). Conclusions: Within the limits of this study, it can be concluded that the immediate loading of one-piece, unsplinted, DMLS titanium mini-implants by means of ball attachment-supported mandibular ODs is a successful treatment procedure. Long-term follow-up studies are needed to confirm these results.
引用
收藏
页码:192 / 200
页数:9
相关论文
共 45 条
[1]  
Alsabeeha Nabeel, 2010, Clin Implant Dent Relat Res, V12 Suppl 1, pe28, DOI 10.1111/j.1708-8208.2009.00152.x
[3]   MINI IMPLANTS FOR DEFINITIVE PROSTHODONTIC TREATMENT: A SYSTEMATIC REVIEW [J].
Bidra, Avinash S. ;
Almas, Khalid .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (03) :156-164
[4]  
Branemark PI, 1977, SCAND J PLAST RECO S, V16, P11
[5]  
Cho Sang-Choon, 2007, Pract Proced Aesthet Dent, V19, P167
[6]  
CUTLER S J, 1958, J Chronic Dis, V8, P699, DOI 10.1016/0021-9681(58)90126-7
[7]  
de Wild M, 2013, TISSUE ENG PT A, V19, P2645, DOI [10.1089/ten.tea.2012.0753, 10.1089/ten.TEA.2012.0753]
[8]   Prosthetic Requirements for Immediate Implant Loading: A Review [J].
El Ghoul, Wiam ;
Chidiac, Jose Johann .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (02) :141-154
[9]   The clinical and radiographic outcome of immediately loaded mini implants supporting a mandibular overdenture. A 3-year prospective study [J].
Elsyad, M. A. ;
Gebreel, A. A. ;
Fouad, M. M. ;
Elshoukouki, A. H. .
JOURNAL OF ORAL REHABILITATION, 2011, 38 (11) :827-834
[10]   Consensus Statements and Clinical Recommendations for Implant Loading Protocols [J].
Gallucci, German O. ;
Benic, Goran I. ;
Eckert, Steven E. ;
Papaspyridakos, Panos ;
Schimmel, Martin ;
Schrott, Alexander ;
Weber, Hans-Peter .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 :287-290