Chitosan-induced Au/Ag nanoalloy dispersed in IL and application in fabricating an ultrasensitive glucose biosensor based on luminol-H2O2-Cu2+/IL chemiluminescence system

被引:14
作者
Chaichi, M. J. [1 ]
Alijanpour, S. O. [1 ]
机构
[1] Univ Mazandaran, Dept Chem, Babol Sar 4741695447, Iran
关键词
Biosensor; Glucose; Chemiluminescence; Covalent immobilization; Au/Ag alloy NPs; Ion liquid; Cu2+; FLOW-THROUGH BIOSENSOR; GOLD NANOPARTICLES; HYDROGEN-PEROXIDE; IONIC LIQUIDS; COVALENT IMMOBILIZATION; HORSERADISH-PEROXIDASE; OXIDASE; GEL; ENZYME; GLASS;
D O I
10.1016/j.jphotobiol.2014.06.016
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A novel glucose biosensor based on the chemiluminescence (CL) detection of enzymatically generated hydrogen peroxide (H2O2) was constructed by one covalent immobilization of glucose oxidase (GOD) in glutaraldehyde-functionalized glass cell. In following, chitosan-induced Au/Ag nanoparticles dispersed in ion liquid (IL) were synthesised and immobilized. on it. Herein, chitosan molecules acted as both the reducing and stabilizing agent for the preparation of NPs and also, as a coupling agent GOD and Au/Ag alloy NPs. In addition to catalyze luminol CL reaction, these NPs offered excellent catalytic activity toward hydrogen peroxide generation in enzymatic reaction between GOD and glucose. The used IL in fabrication of biosensor increased its stability. Also, IL alongside Cu2+ accelerated enzymatic and CL reaction kinetic, and decreased luminol CL reaction optimum pH to 7.5 which would enable sensitive and precision determination of glucose. Under optimum condition, linear response range of glucose was found to be 1.0 x 10(-6)-7.5 x 10(-3) M, and detection limit was 4.0 x 10(-7) M. The CL biosensor exhibited good storage stability, i.e., 90% of its initial response was retained after 2 months storage at pH 7.0. The present CL biosensor has been applied satisfactory to analysis of glucose in real serum and urine samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 44 条
[1]  
Alici B, 2007, TURK J CHEM, V31, P569
[2]   Formation and stability of N-heterocyclic carbenes in water:: The carbon acid pKa of imidazollum cations in aqueous solution [J].
Amyes, TL ;
Diver, ST ;
Richard, JP ;
Rivas, FM ;
Toth, K .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (13) :4366-4374
[3]   Biosensor based on platinum nanoparticles dispersed in ionic liquid and laccase for determination of adrenaline [J].
Brondani, Daniela ;
Scheeren, Carla Weber ;
Dupont, Jairton ;
Vieira, Iolanda Cruz .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) :252-259
[4]   Determination of vitamin C in drugs using of an optimized novel TCPO-Amplex red-gold/silver alloy nanoparticles-H2O2 chemiluminescence method by the Box-Behnken design [J].
Chaichi, M. J. ;
Alijanpour, S. O. .
JOURNAL OF LUMINESCENCE, 2013, 134 :195-200
[5]   Glucose concentration determination based on silica sol-gel encapsulated glucose oxidase optical biosensor arrays [J].
Chang, Gang ;
Tatsu, Yoshiro ;
Goto, Tatsushi ;
Imaishi, Hiromasa ;
Morigaki, Kenichi .
TALANTA, 2010, 83 (01) :61-65
[6]   Reactivity of ionic liquids [J].
Chowdhury, Shahana ;
Mohan, Ram S. ;
Scott, Janet L. .
TETRAHEDRON, 2007, 63 (11) :2363-2389
[7]   Development of photopolymerized fluorescence sensor for glucose analysis [J].
Cubuk, Soner ;
Yetimoglu, Ece Kok ;
Kahraman, M. Vezir ;
Demirbilek, Pinar ;
Firlak, Melike .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 :187-193
[8]  
Dong Shaojun, 2002, J Biotechnol, V82, P303, DOI 10.1016/S1389-0352(01)00048-4
[9]   Efficient one pot synthesis of chitosan-induced gold nanoparticles by microwave irradiation [J].
Fan, Cailin ;
Li, Wei ;
Zhao, Shiju ;
Chen, Jian ;
Li, Xin .
MATERIALS LETTERS, 2008, 62 (20) :3518-3520
[10]   Glucose biosensor based on covalent immobilization of enzyme in sol-gel composite film combined with Prussian blue/carbon nanotubes hybrid [J].
Fu, Guanglei ;
Yue, Xiuli ;
Dai, Zhifei .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (09) :3973-3976