Study on XLPE Cable Voltage Withstand Test and Its Circuit Model

被引:0
|
作者
Ding Yixuan [1 ]
Xu Deguang [2 ]
Li Jihui [3 ]
Wang Wentao [4 ]
Wang Hongqiang [5 ]
机构
[1] Zhengzhou Univ, Sch Elect Engn, Zhengzhou 450001, Peoples R China
[2] North China Univ Water Resources & Elect Power, Sch Elect Power, Zhengzhou 450011, Peoples R China
[3] State Grid Henan Shenqiu Cty Elect Power Supply C, Shenqiu 466300, Peoples R China
[4] State Grid Henan Huaiyang Cty Elect Power Supply, Huaiyang 466700, Peoples R China
[5] State Grid Xinxiang Elect Power Supply Co, Xinxiang 453000, Peoples R China
来源
PROCEEDINGS OF THE 2016 3RD INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING, MANUFACTURING TECHNOLOGY AND CONTROL | 2016年 / 67卷
关键词
XLPE; power cable; voltage withstand test; circuit model;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Analyze the application of resonant voltage withstand test in the XLPE cable voltage withstand test, and the two methods of variable frequency resonant voltage withstand test were compared by an example. By comparison, the resonant voltage test method can effectively simulate the field voltage withstand test of XLPE cable is found. Through the research of the traditional frequency conversion resonance voltage withstand test circuit, a new voltage withstand test model of cable is proposed, and models of young and old are compared by means of the spot testing, the conclusion of the new circuit model can be more accurate to complete the calculation of AC voltage withstand test is validated.
引用
收藏
页码:1906 / 1911
页数:6
相关论文
共 50 条
  • [41] Impulse breakdown superposed on ac voltage in XLPE cable insulation
    Murata, Y
    Katakai, S
    Kanaoka, M
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (03) : 361 - 365
  • [42] THE EFFECT OF MORPHOLOGY ON THE IMPULSE VOLTAGE BREAKDOWN IN XLPE CABLE INSULATION
    FUKUDA, T
    IRIE, S
    ASADA, Y
    MAEDA, M
    NAKAGAWA, H
    YAMADA, N
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (05): : 386 - 391
  • [43] Failure investigation of an underground low voltage XLPE insulated cable
    Ul-Hamid, Anwar
    Soufi, Khaled Y.
    Al-Hadhrami, Luai M.
    Shemsi, Ahsan M.
    ANTI-CORROSION METHODS AND MATERIALS, 2015, 62 (05) : 281 - 287
  • [44] Behavior of XLPE medium voltage cable under switching impulse
    Abdallah, MA
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 364 - 367
  • [45] Electroluminescence due to impulse voltage in cable-grade XLPE
    Bamji, SS
    Tohyama, K
    Bulinski, AT
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (03) : 288 - 294
  • [46] Dielectric properties of operated high voltage XLPE power cable
    Zhu, Xiaohui
    Meng, Zhengzheng
    Wang, Haoming
    Xue, Cheng
    Du, Boxue
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (04): : 1090 - 1095
  • [47] Electroluminescence due to impulse voltage in cable-grade XLPE
    National Research Council of Canada, Ottawa, Ont., Canada
    不详
    IEEE Trans Dielectr Electr Insul, 3 (288-294):
  • [48] High frequency characteristics of a shielded medium voltage XLPE cable
    Mugala, G
    Eriksson, R
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 132 - 136
  • [49] Diagnosis of XLPE cable using the recovery voltage measurement method
    Bashir, Nouruddeen
    Ahmad, Hussein
    2007 5TH STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT, 2007, : 41 - 44
  • [50] Development of high voltage XLPE power cable system in China
    Ying, QL
    Wei, D
    Gao, XQ
    Liu, YG
    Chen, P
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 247 - 253