The effect of cement mantle thickness on strain energy density distribution and prediction of bone density changes around cemented acetabular component

被引:9
|
作者
Sanjay, Devismita [1 ]
Mondal, Subrata [1 ]
Bhutani, Richa [2 ]
Ghosh, Rajesh [1 ]
机构
[1] Indian Inst Technol Mandi, Sch Engn, Biomech Lab, Kamand 175005, Mandi, India
[2] Manipal Inst Technol, Dept Biomed Engn, Manipal, India
关键词
Pelvic bone; cemented acetabular component; cement mantle thickness; bone remodelling; tensile stress; finite element method; TOTAL HIP-ARTHROPLASTY; FINITE-ELEMENT; POLYETHYLENE WEAR; CANCELLOUS BONE; LOAD-TRANSFER; PELVIC BONE; ORIENTATION; FAILURE; MODELS; REPLACEMENTS;
D O I
10.1177/0954411918793448
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cement mantle thickness is known to be one of the important parameters to reduce the failure of the cemented acetabular component. The thickness of the cement mantle is also often influenced by the positioning of the acetabular cup. The aim of this study is to determine the effect of uniform and non-uniform cement mantle thickness on strain energy density distribution and prediction of the possibility of bone remodelling around the acetabular region. Furthermore, tensile stress distribution in the cement mantle due to non-uniform cement mantle thickness was also investigated. Three-dimensional finite element models of intact and 17 implanted pelvic bone were developed based on computed tomography data sets. Results indicate that implantation with non-uniform cement thickness variation in the anterior-posterior direction has a significant influence on strain energy density distribution around the acetabulum as compared to thickness variation in the superior-inferior direction. Increase in density is predicted at the anterior part of the acetabulum, whereas density decrease is predicted at the posterior, inferior and superior part of the acetabulum. The non-uniform cement mantle thickness affected the tensile stress distribution in the cement mantle, in particularly superiorly placed acetabular cup. This study concludes that uniform cement thickness is desired for the longer success of the cemented acetabular component.
引用
收藏
页码:912 / 921
页数:10
相关论文
共 7 条
  • [1] Improvement of the cement mantle of the acetabular component with bone cement spacers - A retrospective analysis of 200 cemented cups
    Lichtinger, TK
    Muller, RT
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998, 118 (1-2) : 75 - 77
  • [2] Improvement of the cement mantle of the acetabular component with bone cement spacers A retrospective analysis of 200 cemented cups
    T. K. Lichtinger
    R. T. Müller
    Archives of Orthopaedic and Trauma Surgery, 1998, 118 : 75 - 77
  • [3] Pelvic Periprosthetic Bone Mineral Density Measurement Around Cemented vs Cementless Acetabular Prostheses
    Jayasuriya, Raveen L.
    Wilkinson, J. Mark
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (01) : 116 - 120
  • [4] Risk factors for a radiolucent line around the acetabular component with an interface bioactive bone cement technique after primary cemented total hip arthroplasty PROGNOSTIC FACTORS FOR A RADIOLUCENT LINE AND IMPROVEMENT OF THE CEMENT-BONE INTERFACE AROUND CEMENTED ACETABULAR COMPONENT WITH AN INTERFACE BIOACTIVE BONE CEMENT TECHNIQUE
    Miyamoto, S.
    Iida, S.
    Suzuki, C.
    Nakatani, T.
    Kawarai, Y.
    Nakamura, J.
    Orita, S.
    Ohtori, S.
    BONE & JOINT OPEN, 2021, 2 (05): : 278 - 292
  • [5] Liner type has no impact on bone mineral density changes around a 3D printed trabecular titanium acetabular component
    Klasan, Antonio
    Bayan, Ali
    Holdaway, Ian
    Farrington, William J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (01)
  • [6] A randomised study of peri-prosthetic bone density after cemented versus trabecular fixation of a polyethylene acetabular component
    Periasamy, K.
    Watson, W. S.
    Mohammed, A.
    Murray, H.
    Walker, B.
    Patil, S.
    Meek, R. M. D.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (08): : 1033 - 1044
  • [7] The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
    Sugiura, Tsutomu
    Yamamoto, Kazuhiko
    Horita, Satoshi
    Murakami, Kazuhiro
    Tsutsumi, Sadami
    Kirita, Tadaaki
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2016, 46 (03) : 152 - 165