Improved algorithm for ballistocardiac artifact removal from EEG simultaneously recorded with fMRI

被引:0
|
作者
Kim, KH [1 ]
Yoon, HW [1 ]
Park, HW [1 ]
机构
[1] Yonsei Univ, Dept Biomed Engn, Wonju, South Korea
来源
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2004年 / 26卷
关键词
EEG; fMRI; artifact removal; adaptive filtering; wavelet transform; teager energy operator;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The simultaneous recording of electroencephalogram (EEG) and functional magnetic resonance image (fMRI) is a promising tool that is capable of providing high spatiotemporal brain mapping. One of the difficulties to obtain high-quality simultaneous EEG/fMRI data comes from the heartbeat artifact induced in the EEG recorded within fMRI scanner. The purpose of this study was to develop a novel algorithm for removing heartbeat artifact, thus overcoming problems associated with previous methods. Our method consists of a mean artifact waveform subtraction, the selective removal of wavelet coefficients, and a recursive least-square adaptive filtering. The recursive least square adaptive filtering operates without dedicated sensor for the reference signal, and only when the mean subtraction and wavelet-based noise removal is not satisfactory. The performance of our system has been assessed using simulated data based on experimental data of various spectral characteristics, and actual experimental data of alpha-wave-dominant normal EEG and epileptic EEG.
引用
收藏
页码:936 / 939
页数:4
相关论文
共 50 条
  • [21] Removal of the ballistocardiographic artifact from EEG-fMRI data: a canonical correlation approach
    Assecondi, Sara
    Hallez, Hans
    Staelens, Steven
    Bianchi, Anna M.
    Huiskamp, Geertjan M.
    Lemahieu, Ignace
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06): : 1673 - 1689
  • [22] EEG signatures of auditory activity correlate with simultaneously recorded fMRI responses in humans
    Mayhew, Stephen D.
    Dirckx, Sharon G.
    Niazy, Rami K.
    Iannetti, Gian D.
    Wise, Richard G.
    NEUROIMAGE, 2010, 49 (01) : 849 - 864
  • [23] Safety and data quality of EEG recorded simultaneously with multi-band fMRI
    Egan, Maximillian K.
    Larsen, Ryan
    Wirsich, Jonathan
    Sutton, Brad P.
    Sadaghiani, Sepideh
    PLOS ONE, 2021, 16 (07):
  • [24] Removal of Artifact from EEG Signal using Differential Evolution Algorithm
    Sheniha, S. Femilin
    Priyadharsini, S. Suja
    Rajan, S. Edward
    2013 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2013, : 134 - 138
  • [25] Hybrid algorithm for multi artifact removal from single channel EEG
    Noorbasha, Sayedu Khasim
    Florence Sudha, Gnanou
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04)
  • [26] Removal of ballistocardiogram artifacts from EEG recorded during continuous fMRI using JADE
    Institute of Biomedical Engineering, Central South University, ChangSha, China
    不详
    不详
    Int. Conf. Bioinformatics Biomedical Eng., iCBBE,
  • [27] A robust algorithm for removing artifacts in EEG recorded during FMRI/EEG study
    Huang, Chih-Hsu
    Ju, Ming-Shaung
    Lin, Chou-Ching K.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2012, 42 (04) : 458 - 467
  • [28] FACET - a "Flexible Artifact Correction and Evaluation Toolbox" for concurrently recorded EEG/fMRI data
    Glaser, Johann
    Beisteiner, Roland
    Bauer, Herbert
    Fischmeister, Florian Ph S.
    BMC NEUROSCIENCE, 2013, 14
  • [29] FACET – a “Flexible Artifact Correction and Evaluation Toolbox” for concurrently recorded EEG/fMRI data
    Johann Glaser
    Roland Beisteiner
    Herbert Bauer
    Florian Ph S Fischmeister
    BMC Neuroscience, 14
  • [30] Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
    Gwin, Joseph T.
    Gramann, Klaus
    Makeig, Scott
    Ferris, Daniel P.
    JOURNAL OF NEUROPHYSIOLOGY, 2010, 103 (06) : 3526 - 3534