Detection of Power Transformer Fault Conditions using Optical Characteristics of Transformer Oil

被引:0
作者
Fauzi, Nur Afini [1 ]
Thiviyanathan, Vimal Angela [1 ]
Leong, Yang Sing [1 ]
Ker, Pin Jern [1 ]
Jamaludin, M. Z. [1 ]
Nomanbhay, Saiffuddin M. [1 ]
Looe, H. M. [2 ]
Lo, C. K. [2 ]
机构
[1] Univ Tenaga Nas, Photon Technol Res Grp, Inst Power Engn, Jalan IKRAM UNITEN, Kajang 43000, Selangor, Malaysia
[2] TNB Res Sdn Bhd, Jalan Ayer Itam, Kajang 43000, Selangor, Malaysia
来源
2018 IEEE 7TH INTERNATIONAL CONFERENCE ON PHOTONICS (ICP) | 2018年
关键词
main transformer tank; On-load-tap-changer; spectrophotometer; transformer oil aging; DISSOLVED-GAS ANALYSIS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power transformers are important in the power transmission and distribution network. A continuous monitoring of the transformer is important in ensuring the prolonged service of the transformer. This paper focuses on the characterization of transformer oil using optical detection method. 10 Transformer oil samples from the main tanks and 11 oil samples from the on-load-tap-changer (OLTC) were obtained for the optical characterization from 200 to 3300 nm. Based on the conventional results interpretation using dissolved gas analysis (DGA) and Duval Triangle, the optical characteristics of the samples in 2120 to 2220 nm clearly demonstrate the detection of electrical discharges of high energy (D2), electrical discharges of low energy (D1) and thermal faults at temperatures above 700 degrees C (T3) faults. This approach provides a quicker and cheaper method to determine the condition of power transformers based on the optical characteristics of transformer oil.
引用
收藏
页数:3
相关论文
共 15 条
[1]  
[Anonymous], 2011, IEC Standard 60567
[2]  
Domun M. K., 1994, COND MON REM LIF ASS, p2/1
[3]   Improving the reliability of transformer gas-in-oil diagnosis [J].
Duval, M ;
Dukarm, J .
IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (04) :21-27
[4]   Calculation of DGA limit values and sampling intervals in transformers in service [J].
Duval, Michel .
IEEE ELECTRICAL INSULATION MAGAZINE, 2008, 24 (05) :7-13
[5]   Dissolved Gas Analysis Evaluation in Electric Power Transformers using Conventional Methods a Review [J].
Faiz, Jawad ;
Soleimani, Milad .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) :1239-1248
[6]  
International Electrotechnical Commission, 1978, Publication, V599, P21
[7]  
Kang PJ, 2000, 2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, P2223, DOI 10.1109/PESW.2000.847701
[8]   The increased dielectric breakdown voltage of transformer oil-based nanofluids by an external magnetic field [J].
Lee, Jong-Chul ;
Seo, Hyeon-Seok ;
Kim, Youn-Jea .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 62 :29-33
[9]   Comparative study and analysis of DGA methods for transformer mineral oil [J].
Muhamad, N. A. ;
Phung, B. T. ;
Blackburn, T. R. ;
Lai, K. X. .
2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, :45-50
[10]  
Sing Leong Yang, 2016, 2016 IEEE International Conference on Power and Energy (PECon), P234, DOI 10.1109/PECON.2016.7951565