Regional suitability of heating tower heat pumps based on technical and economic performance maps

被引:12
作者
Xie, Lingyun [1 ]
Huang, Shifang [1 ]
Ye, Yunyang [2 ]
Zhang, Xiaosong [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
[2] Pacific Northwest Natl Lab, Richland, WA 99352 USA
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Heating tower heat pump; Air-source heat pump; Chiller and boiler; Technological and economic comparison; Performance map; SYSTEM; FROST; REGENERATION; FLOW;
D O I
10.1016/j.enbuild.2021.111048
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heating tower heat pump (HTHP) technology is evolving rapidly owing to its good performance in summer and frost-free operation in winter. However, a lack of comprehensive comparisons between the HTHP and conventional methods, such as the air-source heat pump (ASHP), and the chiller and boiler, significantly limits its applications. To solve this problem, this paper analyzes the technological and economic performance of these three types of systems at 353 locations over China. The principle of energy saving and potential of the HTHP are presented, based on which a comparison of economic performance is conducted by considering the efficiency of energy conversion and cost of the three systems. The results show that the HTHP is superior to the ASHP at most locations in China, with a 10% to 20% higher annual performance factor (APF). For locations in southwest China, this improvement is less than 10% owing to the large regeneration penalty in winter, and minor differences between dry-bulb and wet bulb temperatures in summer. The APF of the HTHP is 10% to 23% higher than the chiller and boiler system in the hot summer and cold winter zone as well as the cold zone. However, the HTHP exhibits no advantage over this system in the severe cold zone because of the low efficiency of the heat pump in winter, or in the hot summer and warm winter zone owing to the small heating load. The results are used to develop technical and economic performance maps to guide the application of the HTHP in different climatic regions. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Numerical study based on one-year monitoring data of groundwater-source heat pumps primarily for heating: a case in Tangshan, China
    Yu, Ziwang
    Zhang, Yanjun
    Hao, Shuren
    Zhang, Jianing
    Li, Xiaoguang
    Cai, Bowei
    Xu, Tianfu
    ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (14)
  • [42] Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage
    Li, Haoran
    Hou, Juan
    Tian, Zhiyong
    Hong, Tianzhen
    Nord, Natasa
    Rohde, Daniel
    ENERGY, 2022, 239
  • [43] Evaluation of the intermittent performance of heating terminals based on exergy analysis: Discriminate the impacts of heat and electricity input
    Sun, Hongli
    Duan, Mengfan
    Yang, Zixu
    Ding, Pei
    Wu, Yifan
    Lin, Borong
    APPLIED ENERGY, 2023, 346
  • [44] Energetic and economic aspects of a heating and cooling district in a mild climate based on closed loop ground source heat pump
    De Carli, Michele
    Galgaro, Antonio
    Pasqualetto, Michele
    Zarrella, Angelo
    APPLIED THERMAL ENGINEERING, 2014, 71 (02) : 895 - 904
  • [45] Simulation and analysis of heat transfer performance of electrical heating fabric at low temperature based on skin tissue
    Li, Jinyu
    Yan, Hangyu
    Ni, Yunfeng
    Fu, Linlin
    Yang, Yunchu
    INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY, 2023, 35 (03) : 363 - 380
  • [46] Study on the thermal performance of thermal energy storage and heating module based on a novel embedded heat pipe
    Zhao, Jiateng
    Dai, Yucheng
    Wang, Zengpeng
    Liu, Yongheng
    Xu, Wang
    Mao, Yu
    Wang, Chongbo
    JOURNAL OF ENERGY STORAGE, 2022, 52
  • [47] Implementation of heat storage and network water cooler for improvement of energy and economic performance of municipal heating plant with biomass fired cogeneration module
    Swierzewski, Mateusz
    Kalina, Jacek
    JOURNAL OF POWER TECHNOLOGIES, 2019, 99 (02): : 131 - 141
  • [48] Performance and feasibility study of a heat pump with modified solar-air source evaporator: Techno-economic analysis for water heating
    Chinnasamy, Subramaniyan
    Prakash, K. B.
    Divyabharathi, R.
    Kalidasan, B.
    Rajamony, Reji Kumar
    Pandey, A. K.
    Fouad, Yasser
    Soudagar, Manzoore Elahi M.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 157
  • [49] AN EXPERIMENTAL STUDY ON THE DEFROSTING PERFORMANCE OF A PCM-BASED REVERSE-CYCLE DEFROSTING METHOD FOR AIR SOURCE HEAT PUMPS
    Qu, Minglu
    Deng, Shiming
    Jiang, Yiqiang
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2010, 18 (04) : 327 - 337
  • [50] Performance comparison between R410A and R32 multi-heat pumps with a sub-cooler vapor injection in the heating and cooling modes
    Cho, Ii Yong
    Seo, HyeongJoon
    Kim, Dongwoo
    Kim, Yongchan
    ENERGY, 2016, 112 : 179 - 187