Constrained components for the unstable hip following total hip arthroplasty: a literature review

被引:59
作者
Williams, J. T., Jr. [1 ]
Ragland, P. S. [1 ]
Clarke, S. [1 ]
机构
[1] Albert Einstein Med Ctr, Dept Orthopaed Surg, Philadelphia, PA 19141 USA
关键词
D O I
10.1007/s00264-006-0191-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patients with chronic instability or late dislocation following total hip arthroplasty often require operative management. Unfortunately, there is an increased risk of recurrent dislocation following revision in these patients. Over the past decade the use of constrained devices for patients with chronic instability has gained increased interest; however, there is a paucity of studies available in the literature regarding the use of these devices. The purpose of this study was to analyze the available literature over the past 15 years, focusing on larger, long-term studies, to obtain recommendations from the respective articles for indications and contraindications for the use of constrained devices. Our review of eight reports included 1,199 hips in 1,148 patients with a total mean follow-up of 51 months ( range, 24 to 124 months). The mean rate of dislocation following revision with a constrained liner was 10% and the mean re-operation rate for reasons other than dislocation was 4%. We concluded that constrained liners are an option for patients who have failed management of instability with other implants, those with instability of unclear etiology, those with cognitive problems who are unable to follow dislocation precautions, those with deficient abductors, and elderly or low-demand individuals with well-positioned implants requiring revision.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 18 条
[1]  
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[2]   The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty - Examining the successes and failures [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Adams, JB ;
Russell, JH ;
Groseth, KL .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :93-102
[3]  
Berry D J, 2001, Instr Course Lect, V50, P265
[4]   Use of constrained acetabular components for hip instability: An average 10-year follow-up study [J].
Bremner, BRB ;
Goetz, DD ;
Callaghan, JJ ;
Capello, WN ;
Johnston, RC .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :131-137
[5]   A constrained liner cemented into a secure cementless acetabular shell [J].
Callaghan, JJ ;
Parvizi, J ;
Novak, CC ;
Bremner, B ;
Shrader, W ;
Lewallen, DG ;
Johnston, RC ;
Goetz, DD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2206-2211
[6]  
CALLAGHAN JJ, 2004, CLIN ORTHOP RELAT R, V429, P117
[7]   High failure rate of a constrained acetabular liner in revision total hip arthroplasty [J].
Della Valle, CJ ;
Chang, D ;
Sporer, S ;
Berger, RA ;
Rosenberg, AG ;
Paprosky, WG .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :103-107
[8]   Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component [J].
Goetz, DD ;
Bremner, BRB ;
Callaghan, JJ ;
Capello, WN ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (11) :2419-2423
[9]  
GOETZ DD, 1998, CLIN ORTHOP RELAT R, V355, P171
[10]   Periprosthetic acetabular bone loss using a constrained acetabular component [J].
Ito, H ;
Matsuno, T .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (02) :137-139