Cooling Performance Prediction for Hydraulic Thermoelectric Radiant Cooling Panels with Experimental Validation

被引:2
作者
Kim, Minseong [1 ]
Kang, Yong-Kwon [1 ]
Joung, Jaewon [1 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Coll Engn, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
关键词
thermoelectric module; radiant cooling panel; cooling performance prediction model; design factor; parametric analysis; impact analysis; THERMAL COMFORT; SYSTEM; DESIGN; VENTILATION;
D O I
10.3390/su142316214
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Thermoelectric technology has been developed as a substitute for existing refrigerants in heating, ventilation, and air-conditioning system applications for building decarbonization. A hydraulic thermoelectric radiant cooling panel (hTERCP) operated based on the Peltier effect can alternate a conventional cooling system using a chiller with refrigerators. This study aimed to develop a cooling performance prediction model for a hTERCP-integrated free cooling system according to the desirable range of five design factors. A mockup model of the hTERCP was constructed and tested in an environmental chamber to verify the proposed simulation model. The simulation and the experimental analysis confirmed that the heat rejection performance of the thermoelectric module (TEM) significantly affects the cooling performance of the hTERCP. The cooling water temperature was the primary design factor for releasing heat from the hot side of the TEM and significantly influenced the cooling performance of the hTERCP. A parametric analysis of the five design factors was conducted to investigate a method for improving the coefficient of performance (COP) of the hTERCP. The cooling water temperature affected the COP by 38.6-45.7%, and the heat exchange area of the cooling surface greatly influenced the cooling performance by 41.4%. The cooling water flow rate, heat exchange effectiveness of the water block, and heat resistance of the hot side were confirmed to have relatively little influence as 9.7-10.2%, 11.9-24.8%, and 0.7-11.1%, respectively.
引用
收藏
页数:17
相关论文
共 40 条
[1]   Spinodal decomposition and nucleation and growth as a means to bulk nanostructured thermoelectrics:: Enhanced performance in Pb1-xSnxTe-PbS [J].
Androulakis, John ;
Lin, Chia-Her ;
Kong, Hun-Jin ;
Uher, Ctirad ;
Wu, Chun-I ;
Hogan, Timothy ;
Cook, Bruce A. ;
Caillat, Thierry ;
Paraskevopoulos, Konstantinos M. ;
Kanatzidis, Mercouri G. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (31) :9780-9788
[2]  
[Anonymous], 2010, 22010 ASHRAE
[3]  
[Anonymous], 2010, THERMAL ENV CONDITIO
[4]  
[Anonymous], TEC112715
[5]   Thermoelectric performance of thermally aged nanostructured bulk materials-a case study of lead chalcogenides [J].
Byrnes, J. ;
Mitchell, D. R. G. ;
Yamini, S. Aminorroaya .
MATERIALS TODAY PHYSICS, 2020, 13 (13)
[6]   Performance evaluation of a thermoelectric ventilation system driven by the concentrated photovoltaic thermoelectric generators for green building operations [J].
Cai, Yang ;
Wang, Wei-Wei ;
Liu, Cheng-Wei ;
Ding, Wen-Tao ;
Liu, Di ;
Zhao, Fu-Yun .
RENEWABLE ENERGY, 2020, 147 :1565-1583
[7]   Analytical and numerical parameter extraction for compact modeling of thermoelectric coolers [J].
Chen, Min ;
Snyder, G. Jeffrey .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 60 :689-699
[8]   Applicability of thermoelectric heat pump in a dedicated outdoor air system [J].
Cheon, Seong-Yong ;
Lim, Hansol ;
Jeong, Jae-Weon .
ENERGY, 2019, 173 :244-262
[9]   CORRELATIONS FOR LAMINAR FORCED CONVECTION IN FLOW OVER AN ISOTHERMAL FLAT PLATE AND IN DEVELOPING AND FULLY DEVELOPED FLOW IN AN ISOTHERMAL TUBE [J].
CHURCHILL, SW ;
OZOE, H .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1973, 95 (03) :416-419
[10]  
Hahm Hyung Chang, 2013, [Korea Journal of Air-Conditioning and Refrigeration Engineering, 설비공학 논문집], V25, P331, DOI 10.6110/KJACR.2013.25.6.331