W-band frequency-swept EPR

被引:29
作者
Hyde, James S. [1 ]
Strangeway, Robert A. [1 ,2 ]
Camenisch, Theodore G. [1 ]
Ratke, Joseph J. [1 ]
Froncisz, Wojciech [3 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Natl Biomed EPR Ctr, Milwaukee, WI 53226 USA
[2] Milwaukee Sch Engn, Dept Elect Engn & Comp Sci, Milwaukee, WI 53202 USA
[3] Jagiellonian Univ, Dept Biophys, PL-30387 Krakow, Poland
基金
美国国家卫生研究院;
关键词
W-band; Frequency agile EPR spectroscopy; SATURATION;
D O I
10.1016/j.jmr.2010.04.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes a novel experiment on nitroxide radical spin labels using a multiarm EPR W-band bridge with a loop-gap resonator (LGR). We demonstrate EPR spectroscopy of spin labels by linear sweep of the microwave frequency across the spectrum. The high bandwidth of the LGR, about 1 GHz between 3 dB points of the microwave resonance, makes this new experiment possible. A frequency-tunable yttrium iron garnet (YIG) oscillator provides sweep rates as high as 1.8 x 10(5) GHz/s, which corresponds to 6.3 kT/s in magnetic field-sweep units over a 44 MHz range. Two experimental domains were identified. In the first, linear frequency sweep rates were relatively slow, and pure absorption and pure dispersion spectra were obtained. This appears to be a practical mode of operation at the present level of technological development. The main advantage is the elimination of sinusoidal magnetic field modulation. In the second mode, the frequency is swept rapidly across a portion of the spectrum, and then the frequency sweep is stopped for a readout period; FID signals from a swept line oscillate at a frequency that is the difference between the spectral position of the line in frequency units and the readout position. If there is more than one line, oscillations are superimposed. The sweep rates using the YIG oscillator were too slow, and the portion of the spectrum too narrow to achieve the full EPR equivalent of Fourier transform (FT) NMR. The paper discusses technical advances required to reach this goal. The hypothesis that trapezoidal frequency sweep is an enabling technology for FT EPR is supported by this study. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 13 条
[1]  
Bahl I., 1988, MICROWAVE SOLID STAT
[2]  
CAMENISCH TG, 2008, IEEE EL INF TECHN C, P66
[3]   CORRELATION NMR-SPECTROSCOPY [J].
DADOK, J ;
SPRECHER, RF .
JOURNAL OF MAGNETIC RESONANCE, 1974, 13 (02) :243-248
[4]   Saturation recovery EPR and ELDOR at W-band for spin labels [J].
Froncisz, Wojciech ;
Camenisch, Theodore G. ;
Ratke, Joseph J. ;
Anderson, James R. ;
Subczynski, Witold K. ;
Strangeway, Robert A. ;
Sidabras, Jason W. ;
Hyde, James S. .
JOURNAL OF MAGNETIC RESONANCE, 2008, 193 (02) :297-304
[5]   Microwave frequency modulation in CW EPR at W-band using a loop-gap resonator [J].
Hyde, James S. ;
Froncisz, Wojciech ;
Sidabras, Jason W. ;
Camenisch, Theodore G. ;
Anderson, James R. ;
Strangeway, Robert A. .
JOURNAL OF MAGNETIC RESONANCE, 2007, 185 (02) :259-263
[6]   SATURATION OF THE MAGNETIC RESONANCE ABSORPTION IN DILUTE INHOMOGENEOUSLY BROADENED SYSTEMS [J].
HYDE, JS .
PHYSICAL REVIEW, 1960, 119 (05) :1492-1495
[7]   SIMULATION OF ELECTRON-SPIN-RESONANCE SPECTRA OF THE OXYGEN-SENSITIVE SPIN-LABEL PROBE CTPO [J].
HYDE, JS ;
SUBCZYNSKI, WK .
JOURNAL OF MAGNETIC RESONANCE, 1984, 56 (01) :125-130
[8]   Space quantization in a gyrating magnetic field [J].
Rabi, II .
PHYSICAL REVIEW, 1937, 51 (08) :0652-0654
[9]   Multipurpose EPR loop-gap resonator and cylindrical TE011 cavity for aqueous samples at 94 GHz [J].
Sidabras, Jason W. ;
Mett, Richard R. ;
Froncisz, Wojciech ;
Camenisch, Theodore G. ;
Anderson, James R. ;
Hyde, James S. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (03)
[10]   Direct-detected rapid-scan EPR at 250 MHz [J].
Stoner, JW ;
Szymanski, D ;
Eaton, SS ;
Quine, RW ;
Rinard, GA ;
Eaton, GR .
JOURNAL OF MAGNETIC RESONANCE, 2004, 170 (01) :127-135