Hemodynamic response to lower body negative pressure in hemodialysis patients

被引:7
|
作者
Nette, RW
Krepel, HP
van den Dorpel, MA
van den Meiracker, AH
Poldermans, D
Boomsma, F
Weimar, W
Zietse, R
机构
[1] Erasmus MC, Dept Internal Med, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
关键词
lower body negative pressure (LBNP); dialysis hypotension; sympathetic tone; myocardial contractility; central venous pressure (CVP);
D O I
10.1016/S0272-6386(03)00028-3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background Hypovolemia is thought to have an important role in the pathogenesis of dialysis-related hypotension. Methods: We studied the effect of hypovolemia simulated by lower body negative pressure (LBNP) in 11 hypotension-prone (HP) and 11 hypotension-resistant (HR) hemodialysis patients. LBNP was applied stepwise from 0 to -20 to -40 mm Hg. Systolic arterial pressure, heart rate, and central venous pressure (CVP) were recorded continuously after cannulation of the right jugular vein. Stroke volume index was measured at each step echocardiographically. At the end of each level of LBNP, blood samples were obtained to measure norepinephrine (NE), epinephrine (E), and atrial natriuretic peptide (ANP) levels. Results: At baseline, UP (12 +/- 5 and 16 7 mm Hg), heart rate (72 +/- 9 and 70 +/- 13 beats/min), cardiac index (2.3 +/- 0.6 and 2.5 +/- 0.9 L/min), NE (median, 341 pg/mL [range, 198 to 789 pg/mL] and 365 pg/mL [range, 177 to 675 pg/mL] or 2.02 nmol/L [range, 1.17 to 4.66 nmol/L] and 2.16 nmol/L [range, 1.05 to 4.00 nmol/L]), E (median, 46 pg/mL [range, 18 to 339 pg/mL] and 58 pg/mL [range, 21 to 122 pg/mL] or 251 pmol/L [range, 98 to 1,951 pmol/L] and 317 pmol/L [range, 115 to 666 pmol/L]) were similar, whereas systolic arterial pressure (141 +/- 26 versus 164 +/- 22 mm Hg) and ANP (median, 441 pg/mL [range, 152 to 1,330 pg/mL] versus 804 pg/mL [range, 517 to 3,560 pg/mL] ng/L) were lower (P < 0.05) in HP patients. In response to LBNP (-40 mm Hg), CVP decreased by 6.5 +/- 4.0 mm Hg in the HP group and 4.9 +/- 4.9 mm Hg in the HR group. In HP patients, this decrease was associated with a greater decrease in SI (37% +/- 16% versus 27% +/- 16%) and systolic arterial pressure (19% +/- 21% versus 4% +/- 14%) than in HR patients. Plasma ANP levels did not change, whereas increases in NE and E levels were similar in HP and HR patients. Conclusion: Patients who frequently experience episodes of hypotension during dialysis also are prone to develop hypotension during LBNP, which results from reduced myocardial contractile reserve and/or inadequate sympathetic tone. (C) 2003 by the National Kidney Foundation, Inc.
引用
收藏
页码:807 / 813
页数:7
相关论文
共 50 条
  • [41] Cardio-respiratory interactions in response to lower-body negative pressure
    Fadil, Rabie
    Verma, Ajay K.
    Sadeghian, Farshid
    Blaber, Andrew P.
    Tavakolian, Kouhyar
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (02)
  • [42] HYSTERESIS IN RESPONSE TO DESCENDING AND ASCENDING LOWER-BODY NEGATIVE-PRESSURE
    TOMASELLI, CM
    FREY, MAB
    KENNEY, RA
    HOFFLER, GW
    JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (02) : 719 - 725
  • [43] Microcirculatory response to lower body negative pressure and the association to large vessel function
    Jonsson, Hanna
    Henricson, Joakim
    Saager, Rolf B.
    Wilhelms, Daniel
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2023, 2023, 12352
  • [44] RESPONSE OF LOCAL VASCULAR VOLUMES TO LOWER BODY NEGATIVE-PRESSURE STRESS
    WOLTHUIS, RA
    LEBLANC, A
    CARPENTIER, WA
    BERGMAN, SA
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1975, 46 (05): : 697 - 702
  • [45] Cardiovascular response to graded lower body negative pressure in young and elderly man
    van Hoeyweghen, R
    Hanson, J
    Stewart, MJ
    Dethune, L
    Davies, I
    Little, RA
    Horan, MA
    Kirkman, E
    EXPERIMENTAL PHYSIOLOGY, 2001, 86 (03) : 427 - 435
  • [46] The Cardiovascular Response to Lower Body Negative Pressure in Humans Depends on Seal Location
    Goswami, N.
    Grasser, E.
    Roessler, A.
    Schneditz, D.
    Hinghofer-Szalkay, H.
    PHYSIOLOGICAL RESEARCH, 2009, 58 (03) : 311 - 318
  • [47] Approximate Entropy in Analysis of Cardiovascular Response to Lower Body Negative Pressure Test
    Strok, Agnieszka
    Cybulski, Gerard
    Gasiorowska, Anna
    Niewiadomski, Wiktor
    Strasz, Anna
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [48] Hemodynamic impact of graded lower body negative pressure on left ventricular diastolic properties: a pressure volume study.
    Berboth, L.
    Zirngast, B.
    Manninger-Wuenscher, M.
    Goswami, N.
    Maechler, H.
    Alogna, A.
    EUROPEAN JOURNAL OF HEART FAILURE, 2022, 24 : 173 - 173
  • [49] Comparing Cardiovascular Responses Between Upper Body Negative Pressure and Lower Body Negative Pressure
    Pollock, Brandon S.
    Burns, Keith J.
    Boka, Kylene
    McDaniel, John
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 879 - 879
  • [50] Construction of a lower body negative pressure chamber
    Esch, Ben T. A.
    Scott, Jessica M.
    Warburton, Darren E. R.
    ADVANCES IN PHYSIOLOGY EDUCATION, 2007, 31 (01) : 76 - 81