Evaluation of stenosis severity of coronary calcified lesions using transluminal attenuation gradient: clinical application of 320-row volume CT

被引:3
|
作者
Yang, Fengfeng [1 ]
Dong, Jie [2 ]
Wang, Wei [3 ]
Wang, Xiuting [1 ]
Fu, Xiaojiao [1 ]
Kumar, Nanda C. [1 ]
Zhang, Tong [1 ]
机构
[1] Harbin Med Univ, Affiliated Hosp 4, Dept Radiol, Harbin 150001, Peoples R China
[2] Harbin Med Univ, Affiliated Hosp 1, Dept Geriatr, Harbin, Peoples R China
[3] Harbin Med Univ, Affiliated Hosp 1, Dept Magnet Resonance Imaging, Harbin, Peoples R China
关键词
X-ray computed tomography; Angiography; Coronary stenosis; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; FRACTIONAL FLOW RESERVE; ARTERY STENOSIS; DIAGNOSTIC PERFORMANCE; RECLASSIFICATION; EXPERIENCE; OUTCOMES; DISEASE;
D O I
10.23736/S0026-4806.17.04862-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The aim of this study was to evaluate the accuracy of transluminal attenuation gradient (TAG) in diagnosing the stenosis degree of difficult lesions to accurately assess the degree of luminal stenosis using coronary computed tomography angiography (CCTA). METHODS: A total of 130 patients consecutively received CCTA and coronary angiography (CAG). The average transluminal Hounsfield units (HU) of the regions of interest were consecutively measured at an interval of 5 mm from the ostium to the distal level, followed by the calculation of TAG. The diagnostic performance of CCTA, TAG and CCTA+TAG for the stenosis degree of coronary calcified lesions and their reclassification for stenosis degree were analyzed, especially for calcified lesions. RESULTS: Compared with CAG, the TAG in CCTA was consistent with the largest stenosis degree of each blood vessel. TAG improved the accuracy of CCTA in the diagnosis of calcified lesions (P<0.0001). When threshold was <=-6.9 HU/10 mm, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CCTA+TAG in the diagnosis of coronary calcified lesions were 90.26%, 95.45%, 98.58% and 73.68%. TAG for calcified lesions had moderate sensitivity (86.61%; 95% CI: 81.8-90.5%) and high specificity (91.20%; 95% CI: 84.8-95.5%). In addition, TAG can help to improve the reclassification of CCTA for coronary stenosis degree, especially for calcified lesions (NRI=0.127, P= 0.045). CONCLUSIONS: TAG can help to improve the diagnostic performance of CCTA for the stenosis degree of lesions, and it may also help to improve the reclassification of the stenosis degree of calcified lesions.
引用
收藏
页码:305 / 316
页数:12
相关论文
共 34 条
  • [1] Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography
    Kato, Etsuro
    Fujimoto, Shinichiro
    Takamura, Kazuhisa
    Kawaguchi, Yuko
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    HEART AND VESSELS, 2018, 33 (05) : 462 - 469
  • [2] Improved diagnostic performance of transluminal attenuation gradient in combination with morphological evaluation of coronary artery stenosis using 320-row computed tomography
    Nagata, Kyohei
    Tanaka, Ryoichi
    Takagi, Hidenobu
    Fusazaki, Tetuya
    Morino, Yoshihiro
    Yoshioka, Kunihiro
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (01) : 51 - 58
  • [3] Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography
    Etsuro Kato
    Shinichiro Fujimoto
    Kazuhisa Takamura
    Yuko Kawaguchi
    Chihiro Aoshima
    Makoto Hiki
    Kanako K. Kumamaru
    Hiroyuki Daida
    Heart and Vessels, 2018, 33 : 462 - 469
  • [4] Improved diagnostic performance of transluminal attenuation gradient in combination with morphological evaluation of coronary artery stenosis using 320-row computed tomography
    Kyohei Nagata
    Ryoichi Tanaka
    Hidenobu Takagi
    Tetuya Fusazaki
    Yoshihiro Morino
    Kunihiro Yoshioka
    Japanese Journal of Radiology, 2018, 36 : 51 - 58
  • [5] Diagnostic value of coronary transluminal attenuation gradient in coronary CT Angiography to assess the severity of stenosis
    Karami, Mehdi
    Akbari, Pooya
    Moradi, Maryam
    Farghadani, Maryam
    Alikhani, Fariba
    MEDICAL SCIENCE, 2020, 24 (103) : 1052 - 1060
  • [6] Transluminal attenuation gradient in coronary computed tomography angiography for determining stenosis severity of calcified coronary artery: a primary study with dual-source CT
    Zheng, Minwen
    Wei, Mengqi
    Wen, Didi
    Zhao, Hongliang
    Liu, Ying
    Li, Jiayi
    Li, Jian
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1219 - 1228
  • [7] Diagnostic Performance of Transluminal Attenuation Gradient and Noninvasive Fractional Flow Reserve Derived from 320-Detector Row CT Angiography to Diagnose Hemodynamically Significant Coronary Stenosis: An NXT Substudy
    Ko, Brian S.
    Wong, Dennis T. L.
    Norgaard, Bjarne L.
    Leong, Darryl P.
    Cameron, James D.
    Gaur, Sara
    Marwan, Mohamed
    Achenbach, Stephan
    Kuribayashi, Sachio
    Kimura, Takeshi
    Meredith, Ian T.
    Seneviratne, Sujith K.
    RADIOLOGY, 2016, 279 (01) : 75 - 83
  • [8] Does vessel length impact transluminal attenuation gradient in 320-slice coronary CT angiography? Correlation with invasive angiography
    Xu, Nan
    Peng, Kun
    Dai, Shun
    Zhang, Lei
    Yu, Hong
    Dai, Gonghua
    Jin, Liqing
    Hu, Bo
    Tang, Guangyu
    EUROPEAN RADIOLOGY, 2019, 29 (12) : 6837 - 6845
  • [9] Transluminal attenuation-gradient coronary CT angiography on a 320-MDCT volume scanner: Effect of scan timing, coronary artery stenosis, and cardiac output using a contrast medium flow phantom
    Funama, Yoshinori
    Utsunomiya, Daisuke
    Oda, Seitaro
    Shimonobo, Toshiaki
    Nakaura, Takeshi
    Mukunoki, Toshifumi
    Kidoh, Masafumi
    Yuki, Hideaki
    Yamashita, Yasuyuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1415 - 1421
  • [10] Subtraction Coronary CT Angiography for the Evaluation of Severely Calcified Lesions Using a 320-Detector Row Scanner
    Yoshioka K.
    Tanaka R.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 437 - 446