Gatifloxacin photocatalytic degradation in different water matrices: Antimicrobial activity and acute toxicity reduction

被引:9
作者
Caianelo, Marlon [1 ]
Espindola, Jonathan C. [2 ]
Diniz, Vinicius [3 ]
Spina, Mylena [1 ]
Rodrigues-Silva, Caio [3 ]
Guimaraes, Jose Roberto [1 ]
机构
[1] Univ Estadual Campinas, Sch Civil Engn Architecture & Urban Design, POB 6143, BR-13083889 Campinas, Brazil
[2] Univ Sao Paulo, Polytech Sch, Int Reference Ctr Water Reuse, IRCWR USP,Environm & Hydraul Dept PHA,USP, BR-05508020 Sao Paulo, SP, Brazil
[3] Univ Estadual Campinas, Inst Chem, Dept Analyt Chem, POB 6154, BR-13084971 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Advanced oxidation process; Titanium dioxide; Fluoroquinolone; Microtox (R); Heterogeneous photocatalysis; FLUOROQUINOLONE ANTIBIOTICS; PHOTODEGRADATION; OXIDATION; PHASE; BACTERIA; LIGHT; P25; UV;
D O I
10.1016/j.jphotochem.2022.113973
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The main goal of this study is to evaluate the feasibility of using heterogeneous photocatalysis to degrade the organic contaminant gatifloxacin (GAT) and reduce the antimicrobial activity and acute toxicity from different water matrices. Assays were performed using four water matrices (ultrapure water -UW, mineral water -MW, potable water -PW, and simulated surface water -SW) fortified with gatifloxacin (500 mu g L-1) as a model antibiotic contaminant and its quantification was followed using online SPE-UHPLC-MS/MS. Initially, the photocatalytic process efficiency towards GAT removal as a function of UV light wavelength (UVA and UVC), catalyst type (TiO2-P25 or TiO2-PC500), photocatalyst loading (from 1 to 200 mg TiO2 L-1), solution pH (from 4 to 9), GAT initial concentration (from 50 mu g GAT L-1 to 5000 mu g GAT L-1) and water matrix (UW, MW, SW or PW) was assessed. In this context, the TiO2-PC500 system using UVA showed the best removal performance of GAT. With TiO2-PC500 loadings higher than 10 mg L-1, > 90% of GAT degradation was achieved after only 40 min of reaction. Finally, the system efficiency was evaluated according to its ability to reduce the antimicrobial activity of the solutions against Gram-negative and Gram-positive bacteria as well as their acute toxicity to A. fischeri bacterium. The antimicrobial activity in the solutions dropped along the reaction time, but no toxicity variation was observed.
引用
收藏
页数:9
相关论文
共 36 条
[31]   Tracking the occurrence of psychotropic pharmaceuticals in Brazilian wastewater treatment plants and surface water, with assessment of environmental risks [J].
Pivetta, Rhannanda Copetti ;
Rodrigues-Silva, Caio ;
Ribeiro, Alyson Rogerio ;
Rath, Susanne .
SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 727
[32]   EVALUATION OF RESIDUAL ANTIMICROBIAL ACTIVITY OF FLUMEQUINE SOLUTIONS SUBJECTED TO ELECTROCHEMICAL AND PHOTO-ELECTROCHEMICAL PROCESSES [J].
Rodrigues-Silva, Caio ;
Maniero, Milena G. ;
Guimaraes, Jose Roberto .
QUIMICA NOVA, 2014, 37 (05) :789-795
[33]   Humic acids removal in a photocatalytic membrane reactor with a ceramic UF membrane [J].
Szymanski, Kacper ;
Morawski, Antoni W. ;
Mozia, Sylwia .
CHEMICAL ENGINEERING JOURNAL, 2016, 305 :19-27
[34]   Photochemical transformation of fentanyl under the simulated solar radiation - Enhancement of the process by heterogeneous photocatalysis and in silico analysis of toxicity [J].
Trawinski, Jakub ;
Szpot, Pawel ;
Zawadzki, Marcin ;
Skibinski, Robert .
SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 791 (791)
[35]   Trace analysis of quinolone and fluoroquinolone antibiotics from wastewaters by liquid chromatography-electrospray tandem mass spectrometry [J].
Xiao, Yang ;
Chang, Hong ;
Jia, Ai ;
Hu, Jianying .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1214 (1-2) :100-108
[36]   Photodegradation and toxicity changes of antibiotics in UV and UV/H2O2 process [J].
Yuan, Fang ;
Hu, Chun ;
Hu, Xuexiang ;
Wei, Dongbin ;
Chen, Yong ;
Qu, Jiuhui .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 185 (2-3) :1256-1263