Gas analyzer for continuous monitoring of carbon dioxide in gas streams

被引:12
作者
Marzouk, Sayed A. M. [1 ]
Al-Marzouqi, Mohamed H. [2 ]
机构
[1] UAE Univ, Dept Chem, Al Ain, U Arab Emirates
[2] UAE Univ, Dept Chem & Petr Engn, Al Ain, U Arab Emirates
关键词
CO2 gas analyzer; In-line gas analysis; Hollow fiber membrane contactors; pH detector; DIFFUSION-FLOW INJECTION; CONDUCTOMETRIC DETECTOR; CERAMIC OXIDE; SENSOR; CO2; ELECTRODE; WATER;
D O I
10.1016/j.snb.2009.12.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction and characterization of a simple and inexpensive gas analyzer setup for direct measurement of CO2 concentration in gas streams are presented. The analyzer was based on a hollow fiber membrane (HFM) contactor which served as a mean for continuous gas sampling and preconcentration of CO2 from the gas stream into a dilute buffer carrier solution. The resultant pH changes of the carrier solution were measured downstream by a pH flow-through detector. A Nernstian response of 55.5 mV/log[CO2] was obtained over a wide dynamic range of 0.1-100% CO2 in nitrogen. Moreover, the presented analyzer offered several favorable performance characteristics such as fast response (45 s) and recovery times (1-2 min), excellent signal stability and reproducibility (RSD= 1.2%) and intrinsic high selectivity in the presence of most common neutral gases (e.g., CH4, N-2, O-2, CO, etc.). H2S and SO2 which are potentially interfering acidic gases were efficiently removed by a simple prior in-line treatment using acidified potassium permanganate bubbler. The analyzer was applied successfully to monitor the treatment process of CO2 removal from CO2-CH4 gas mixtures. The merits of the developed analyzer suggest its reliable use in various applications requiring continuous carbon dioxide monitoring in gas streams for several hours. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:398 / 404
页数:7
相关论文
共 31 条
  • [1] Removal from CO2-CH4 Gas Mixture Using Different Solvents and Hollow Fiber Membranes
    Al-Marzouqi, Mohamed H.
    Marzouk, Sayed A. M.
    El-Naas, Muftah H.
    Abdullatif, Nadia
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (07) : 3600 - 3605
  • [2] The development of a membrane-covered microelectrode array gas sensor for oxygen and carbon dioxide measurement
    Anjos, Tania G.
    Hahn, Clive E. W.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) : 224 - 229
  • [3] Baker R.W., 2007, Membrane technology and applications
  • [4] Development of an optical sensor probe for the detection of dissolved carbon dioxide
    Burke, Conor S.
    Markey, Adam
    Nooney, Robert I.
    Byme, Patrick
    McDonagh, Colette
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (01) : 288 - 294
  • [5] Fiber-optic carbon dioxide sensor based on fluorinated xerogels doped with HPTS
    Chu, Chen-Shane
    Lo, Yu-Lung
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) : 120 - 125
  • [6] Micromachined thin film solid state electrochemical CO2, NO2 and SO2 gas sensors
    Currie, JF
    Essalik, A
    Marusic, JC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 59 (2-3) : 235 - 241
  • [7] CO2 and H2 detection with a CHx/porous silicon-based sensor
    Gabouze, N
    Belhousse, S
    Cheraga, H
    Ghellai, N
    Ouadah, Y
    Belkacem, Y
    Keffous, A
    [J]. VACUUM, 2006, 80 (09) : 986 - 989
  • [8] Hanan J.J., 1998, GREENHOUSES
  • [9] POTENTIOMETRIC GAS SENSOR FOR THE SELECTIVE DETERMINATION OF AZIDES
    HASSAN, SSM
    AHMED, MA
    MARZOUK, SAM
    ELNEMMA, EM
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (15) : 1547 - 1552
  • [10] AMPEROMETRIC CARBON-DIOXIDE GAS SENSOR-BASED ON ELECTRODE REDUCTION OF PLATINUM OXIDE
    ISHIJI, T
    TAKAHASHI, K
    KIRA, A
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (20) : 2736 - 2739