Novel architecture and algorithm for remote interrogation of battery-free sensors

被引:23
作者
Jacquemod, Gilles [1 ]
Nowak, Michel [1 ,2 ]
Colinet, Eric [2 ]
Delorme, Nicolas [2 ]
Conseil, Francois [3 ]
机构
[1] CNRS, UMR UNS 6071, LEAT, F-06034 Nice, France
[2] MINATEC, DCIS, LETI, CEA, Grenoble, France
[3] MBDA, Paris, France
关键词
Passive telemetry; Battery-free sensors; SOL architecture; BIMBO algorithm; RESONANT-CIRCUIT; WIRELESS;
D O I
10.1016/j.sna.2010.03.041
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an inductive telemetry platform system for the continuous, real-time and simultaneous remote measurement in harsh environment. First, a SOL (self-oscillating loop) topology for the remote interrogation of wireless battery-less passive sensors is described. This system uses a capacitive sensor configured as an LC-tank whose resonant frequency shifts with the physical measurement. Such a system is generally based on an impedance analyzer in order to measure this frequency shift. In fact, if you increase the distance between the sensor and the reader, the sensibility is not sufficient to use the SOL technique. To overcome this issue, an anti-resonance cancellation, realized with a simple RC cell, is implemented. However, this architecture is dedicated only for a single capacitive sensor. Second, based on an efficient algorithm used for system identification purpose, a readout unit for multiple sensors is proposed. The overall performances of these architectures are analyzed with respect to coupling factor and sensor parameters. Using these two approaches, tests show promising results at mutual coil distances up to 5 cm. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 14 条
[1]  
[Anonymous], 1999, SYSTEM IDENTIFICATIO
[2]   Wireless, passive, resonant-circuit, inductively coupled, inductive strain sensor [J].
Butler, JC ;
Vigliotti, AJ ;
Verdi, FW ;
Walsh, SM .
SENSORS AND ACTUATORS A-PHYSICAL, 2002, 102 (1-2) :61-66
[3]   A miniature pressure system with a capacitive sensor and a passive telemetry link for use in implantable applications [J].
Chatzandroulis, S ;
Tsoukalas, D ;
Neukomm, PA .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) :18-23
[4]  
Finkenzeller K., 2003, RFID HDB FUNDAMENTAL, V2nd ed.
[5]   One-chip integrated resonance circuit with a capacitive pressure sensor [J].
Husak, M .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (03) :173-178
[6]   Digital Implementation of a BIST Method based on Binary Observations [J].
Le Blanc, C. ;
Colinet, E. ;
Juillard, J. ;
Anghel, L. .
11TH EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN - ARCHITECTURES, METHODS AND TOOLS : DSD 2008, PROCEEDINGS, 2008, :709-+
[7]  
MIESTERFELD FOR, 1977, Patent No. 4021681
[8]   A new passive telemetry LC pressure and temperature sensor optimized for TPMS [J].
Nabipoor, M. ;
Majlis, B. Y. .
INTERNATIONAL MEMS CONFERENCE 2006, 2006, 34 :770-775
[9]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[10]  
NOWAK M, 2008, SMART SYST INTEGRATI, P73