A Novel Open-Circuit Fault Detection and Localization Scheme for Cascaded H-Bridge Stage of a Three-Stage Solid-State Transformer

被引:33
|
作者
Gorla, Naga Brahmendra Yadav [1 ]
Kolluri, Sandeep [1 ]
Chai, Merlin [1 ]
Panda, Sanjib Kumar [1 ]
机构
[1] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 117581, Singapore
基金
新加坡国家研究基金会;
关键词
Circuit faults; Switches; Voltage measurement; Fault detection; Switching frequency; Phase modulation; Cascaded multilevel converter (MMC); fault detection and localization; multiple switch failures; open-circuit (OC) faults; solid-state transformer (SST); MODULAR MULTILEVEL CONVERTERS; POWER BALANCE CONTROL; VOLTAGE; PROTECTION; FAILURES;
D O I
10.1109/TPEL.2019.2918148
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A three-stage solid-state transformer (SST) is a preferred replacement for line frequency transformer as it provides ancillary services in addition to stepping-up/down of grid voltages. Each active switch in SST is a potential source of failure, and a quick fault detection and isolation help in reducing the downtime. In this article, a novel fault detection and localization algorithm is proposed to localize the open-circuit (OC) faults (be it a single switch fault or multiple switch faults in multiple modules) in the cascaded H-bridge (CHB) stage of the SST. The proposed method is designed such that only one voltage sensor is needed to measure the grid-side voltage of the CHB for fault detection and localization. By comparing the estimated grid-side voltage of the CHB with the measured values, OC fault is detected. Once the fault is detected, the modulation scheme is switched from phase-shifted unipolar sinusoidal pulsewidth modulation (SPWM) to phase-shifted bipolar SPWM to localize the faults. The difference in the measured grid-side voltage of the CHB before and after each module's state change is calculated and faults are localized. The presented algorithm is substantiated using experimental results from a 1-kVA SST prototype. The main advantage of the proposed algorithm is that it requires only 2n comparisons to localize the faulty modules in a CHB with n H-bridges, which takes less than a line cycle to complete.
引用
收藏
页码:8713 / 8729
页数:17
相关论文
共 19 条
  • [1] An Open-Circuit Fault Detection and Localization Scheme for Cascaded H-Bridge Multilevel Converter Without Additional Sensors
    Gorla, Naga Brahmendra Yadav
    Kolluri, Sandeep
    Chai, Merlin
    Panda, Sanjib Kumar
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (01) : 457 - 467
  • [2] An Open-Circuit Switch Fault Detection Strategy for a Three-Stage Cascaded Boost Converter
    Khwan-on, Sudarat
    Diewsurin, Supanut
    2018 6TH INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2018,
  • [3] A power switch open-circuit fault-tolerant scheme using dc current injection for dual active bridge converters in cascaded h-bridge solid-state transformer
    Zang, Jiajie
    Wang, Jiacheng
    Zhang, Jianwen
    Zhou, Jianqiao
    Shi, Gang
    Feng, Xin
    Zhang, Yixin
    IET POWER ELECTRONICS, 2023, 16 (07) : 1214 - 1226
  • [4] A Start-Up Scheme for a Three-Stage Solid-State Transformer With Minimized Transformer Current Response
    Liu, Xiaohu
    Li, Hui
    Wang, Zhan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (12) : 4832 - 4836
  • [5] Open Circuit Switch Fault Detection in Flying Capacitor and Cascaded H-Bridge Multilevel Converters
    Hekmati, Parham
    Brown, Ian P.
    Shen, Z. John
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (11) : 12332 - 12341
  • [6] An Open-Circuit Fault Detection Method using Wavelet Transform for Cascaded H-Bridge Multilevel Inverter
    Valipour, Saeed
    Moosavi, S. Saeid
    Khaburi, D. A.
    Djerdir, A.
    2017 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2017,
  • [7] Soft-Start Procedure for a Three-Stage Smart Transformer Based on Dual-Active Bridge and Cascaded H-Bridge Converters
    Pugliese, Sante
    Buticchi, Giampaolo
    Mastromauro, Rosa Anna
    Andresen, Markus
    Liserre, Marco
    Stasi, Silvio
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (10) : 11039 - 11052
  • [8] A Novel Transistor Open-Circuit Fault Localization Scheme for Three-Phase Dual Active Bridge
    Davoodi, Amirali
    Sadeghpour, Danial
    Kashif, Muhammad
    Albahrani, Sayed Ali
    Atarodi, Seyed Mojtaba
    Zolghadri, MohammadReza
    2018 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2018,
  • [9] Hybrid Fault Diagnosis of Multiple Open-Circuit Faults for Cascaded H-Bridge Multilevel Converter Based on Perturbation Estimation Convolution Network
    Fan, Chenxi
    Xiahou, Kaishun
    Wang, Lei
    Wu, Q. H.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [10] A Counter-Based Open-Circuit Switch Fault Diagnostic Method for a Single-Phase Cascaded H-Bridge Multilevel Converter
    Lin, Hongjian
    Lin, Chunxu
    Xie, Dong
    Acuna, Pablo
    Liu, Wenqiang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (01) : 814 - 825