Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?

被引:22
作者
Lazennec, Jean Yves [1 ]
Chometon, Quentin [1 ]
Folinais, Dominique [1 ]
Robbins, Christopher B. [1 ]
Pour, Aidin Eslam [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Knee; Coronal knee alignment; Hip-knee-ankle angle; Three-dimensional imaging; Radiographs; HIGH TIBIAL OSTEOTOMY; LOWER-LIMB; ARTHROPLASTY; VARUS; OSTEOARTHRITIS; PROGRESSION; RECONSTRUCTION; RADIOGRAPHS; DEFORMITY; SURVIVAL;
D O I
10.1007/s00264-016-3340-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Coronal malalignment of the lower extremity is closely related to the onset and progression of osteoarthritis. Restoring satisfactory alignment after tibial osteotomy improves the long-term success of this conservative surgery. The purpose of our study was to determine (1) if there is a difference between two-dimensional (2D) and 3D measurements of the hip-knee-ankle (HKA) angle between the mechanical axes of the femur and the tibia, (2) which parameter most affects 2D-3D HKA measurement, and (3) the percentage of patients who are at risk of error in HKA measurement. Methods We reviewed imaging studies of the consecutive patients referred to us for hip or knee pain between June and October 2013. Patients with previous pelvis or lower extremity surgery were excluded. Results In 51 % (95/186) of lower extremities examined, the 3D method showed more valgus than the 2D method, and in 49 % (91/186), the 3D method showed more varus. In 12 % of extremities (23/186), the knee varus or valgus alignment was completely opposite in 3D images compared to 2D images. Having more than 7A degrees of flexum/recurvatum alignment increased error in 2D HKA measurement by 5.7A degrees. This was calculated to be 0.15A degrees per 1A degrees increase in femoral torsion and 0.05A degrees per 1A degrees increase in tibial torsion. Approximately 20 % of patients might be at risk of error in HKA angle measurement in 2D imaging studies. Conclusions Orthopaedic surgeons should assess lower extremity alignment in standing position, with enough exposure of the extremity to find severe alignment or rotational deformities, and consider advanced 3D images of those patients who have them. Otherwise, HKA angle can be measured with good accuracy with 2D techniques.
引用
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [31] Development and validation of a clinical tool to semi-automatic measure three-dimensional TAR alignment on two-dimensional radiographs
    van Hoogstraten, Sanne W. G.
    Hermus, Joris
    Verbiest, Vera
    van Rietbergen, Bert
    Arts, Jacobus J. C.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2023, 16 (01)
  • [32] Three-dimensional gait analysis of lower extremity gait parameters in Japanese children aged 6 to 12 years
    Ito, Tadashi
    Noritake, Koji
    Ito, Yuji
    Tomita, Hidehito
    Mizusawa, Jun
    Sugiura, Hiroshi
    Matsunaga, Naomichi
    Ochi, Nobuhiko
    Sugiura, Hideshi
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [33] Knee Imaging: Rapid Three-Dimensional Fast Spin-Echo Using Compressed Sensing
    Kijowski, Richard
    Rosas, Humberto
    Samsonov, Alexey
    King, Kevin
    Peters, Rob
    Liu, Fang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (06) : 1712 - 1722
  • [34] Significance of three-dimensional turbo spin-echo magnetic resonance imaging with semiquantitative assessment of knee osteoarthritis: correlation to two-dimensional routine magnetic resonance imaging
    Hashem, Aya Mohamed Bassam
    El-Liethy, Nevien Ezzat Mohamed
    El-Din, Osama Mohamed Helmy Noor
    Mahmoud, Mostafa Ezzat
    Hashem, Lamiaa Mohamed Bassam
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01)
  • [35] Volume rendering based on magnetic resonance imaging: advances in understanding the three-dimensional anatomy of the human knee
    Anastasi, Giuseppe
    Bramanti, Placido
    Di Bella, Paolo
    Favaloro, Angelo
    Trimarchi, Fabio
    Magaudda, Ludovico
    Gaeta, Michele
    Scribano, Emanuele
    Bruschetta, Daniele
    Milardi, Demetrio
    JOURNAL OF ANATOMY, 2007, 211 (03) : 399 - 406
  • [36] Three-dimensional diffuse optical imaging of hand joints: System description and phantom studies
    Zhang, QZ
    Jiang, HB
    OPTICS AND LASERS IN ENGINEERING, 2005, 43 (11) : 1237 - 1251
  • [37] Generation and Control of Wide-Field Three-Dimensional Structured Illumination for Advanced Microscopic Imaging
    Usuki, Shin
    Kanaka, Hiroyoshi
    Miura, Kenjiro T.
    PROCEEDINGS OF PRECISION ENGINEERING AND NANOTECHNOLOGY (ASPEN2011), 2012, 516 : 640 - +
  • [38] Three-dimensional Advanced Tomographic Procedure for the Imaging of Metallic and Dielectric Targets through GPR Data
    Murgia, Federica
    Comite, Davide
    Catapano, Ilaria
    Soldovieri, Francesco
    Galli, Alessandro
    2018 15TH EUROPEAN RADAR CONFERENCE (EURAD), 2018, : 10 - 13
  • [39] A Three-Dimensional Quantitative Method to Measure Meniscus Shape, Position, and Signal Intensity Using MR Images: A Pilot Study and Preliminary Results in Knee Osteoarthritis
    Wirth, Wolfgang
    Frobell, Richard B.
    Souza, Richard B.
    Li, Xiaojuan
    Wyman, Bradley T.
    Le Grayerand, Marie-Pierre Hellio
    Link, Thomas M.
    Majumdar, Sharmila
    Eckstein, Felix
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1162 - 1171
  • [40] Three-dimensional turbo spin-echo magnetic resonance imaging (MRI) and semiquantitative assessment of knee osteoarthritis: comparison with two-dimensional routine MRI
    Crema, M. D.
    Nogueira-Barbosa, M. H.
    Roemer, F. W.
    Marra, M. D.
    Niu, J.
    Chagas-Neto, F. A.
    Gregio-Junior, E.
    Guermazi, A.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (03) : 428 - 433