Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?

被引:22
作者
Lazennec, Jean Yves [1 ]
Chometon, Quentin [1 ]
Folinais, Dominique [1 ]
Robbins, Christopher B. [1 ]
Pour, Aidin Eslam [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Knee; Coronal knee alignment; Hip-knee-ankle angle; Three-dimensional imaging; Radiographs; HIGH TIBIAL OSTEOTOMY; LOWER-LIMB; ARTHROPLASTY; VARUS; OSTEOARTHRITIS; PROGRESSION; RECONSTRUCTION; RADIOGRAPHS; DEFORMITY; SURVIVAL;
D O I
10.1007/s00264-016-3340-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Coronal malalignment of the lower extremity is closely related to the onset and progression of osteoarthritis. Restoring satisfactory alignment after tibial osteotomy improves the long-term success of this conservative surgery. The purpose of our study was to determine (1) if there is a difference between two-dimensional (2D) and 3D measurements of the hip-knee-ankle (HKA) angle between the mechanical axes of the femur and the tibia, (2) which parameter most affects 2D-3D HKA measurement, and (3) the percentage of patients who are at risk of error in HKA measurement. Methods We reviewed imaging studies of the consecutive patients referred to us for hip or knee pain between June and October 2013. Patients with previous pelvis or lower extremity surgery were excluded. Results In 51 % (95/186) of lower extremities examined, the 3D method showed more valgus than the 2D method, and in 49 % (91/186), the 3D method showed more varus. In 12 % of extremities (23/186), the knee varus or valgus alignment was completely opposite in 3D images compared to 2D images. Having more than 7A degrees of flexum/recurvatum alignment increased error in 2D HKA measurement by 5.7A degrees. This was calculated to be 0.15A degrees per 1A degrees increase in femoral torsion and 0.05A degrees per 1A degrees increase in tibial torsion. Approximately 20 % of patients might be at risk of error in HKA angle measurement in 2D imaging studies. Conclusions Orthopaedic surgeons should assess lower extremity alignment in standing position, with enough exposure of the extremity to find severe alignment or rotational deformities, and consider advanced 3D images of those patients who have them. Otherwise, HKA angle can be measured with good accuracy with 2D techniques.
引用
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [21] Three-dimensional assessment of lower limb alignment: Reference values and sex-related differences
    Degen, N.
    Sass, J.
    Jalali, J.
    Kovacs, L.
    Euler, E.
    Prall, W. C.
    Boecker, W.
    Thaller, P. H.
    Fuermetz, J.
    KNEE, 2020, 27 (02) : 428 - 435
  • [22] A comparison of measuring mechanical axis alignment using three-dimensional position capture with skin markers and radiographic measurements in patients with bilateral medial compartment knee osteoarthritis
    Muendermann, Annegret
    Dyrby, Chris O.
    Andriacchi, Thomas P.
    KNEE, 2008, 15 (06) : 480 - 485
  • [23] The impact of body-Mass index on the frontal knee alignment estimation using three-dimensional reconstruction based on movement analysis
    Legrand, Thomas
    Richard, Vincent
    Bonnefoy-Mazure, Alice
    Armand, Stephane
    Miozzari, Hermes H.
    Turcot, Katia
    KNEE, 2020, 27 (01) : 89 - 94
  • [24] Three-dimensional analysis of accuracy of patient-matched instrumentation in total knee arthroplasty: Evaluation of intraoperative techniques and postoperative alignment
    Kuwashima, Umito
    Mizu-uchi, Hideki
    Okazaki, Ken
    Hamai, Satoshi
    Akasaki, Yukio
    Murakami, Koji
    Nakashima, Yasuharu
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (06) : 1077 - 1083
  • [25] Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequence
    Lee, Seung Hyun
    Lee, Young Han
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2018, 46 : 90 - 97
  • [26] Analysis of Three-Dimensional In Vivo Knee Kinematics Using Dynamic Magnetic Resonance Imaging
    Ma, C. Benjamin
    Lee, Keh-yang
    Schrumpf, Mark A.
    Majumdar, Sharmila
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2005, 15 (01) : 57 - 63
  • [27] Three-dimensional imaging is a novel and reliable technique to measure total body surface area
    Rashaan, Z. M.
    Euser, A. M.
    van Zuijlen, P. P. M.
    Breederveld, R. S.
    BURNS, 2018, 44 (04) : 816 - 822
  • [28] In vivo three-dimensional magnetic resonance imaging of rat knee osteoarthritis model induced using meniscal transection
    Wang, Yi-Xiang J.
    Wang, Junqing
    Deng, Min
    Liu, Gang
    Qin, Ling
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2015, 3 (03) : 134 - 141
  • [29] Optimizing Isotropic Three-Dimensional Fast Spin-Echo Methods for Imaging the Knee
    Li, Charles Q.
    Chen, Weitian
    Rosenberg, Jarrett K.
    Beatty, Philip J.
    Kijowski, Richard
    Hargreaves, Brian A.
    Busse, Reed F.
    Gold, Garry E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (06) : 1417 - 1425
  • [30] Analysis of knee-bending motion through three-dimensional scanning for advanced brace design
    Pierre, Ringenbach
    Yu, Annie
    Zhang, Yijia
    TEXTILE RESEARCH JOURNAL, 2024, : 2682 - 2694