Management of malfunctioning and recalled pacemaker and defibrillator leads: results of the European Heart Rhythm Association survey

被引:23
作者
Bongiorni, Maria Grazia [1 ]
Dagres, Nikolaos [2 ]
Estner, Heidi [3 ,4 ]
Pison, Laurent [5 ]
Todd, Derick [6 ]
Blomstrom-Lundqvist, Carina [7 ]
机构
[1] Univ Hospital Pisa, CardioThorac & Vasc Dept, Pisa, Italy
[2] Univ Athens, Attikon Univ Hosp, Cardiol Dept 2, Athens, Greece
[3] LMU Klinikum, Dept Cardiol Med Klin & Poliklin, Munich, Germany
[4] Univ Munich, Munich, Germany
[5] Maastricht Univ, Med Ctr, Dept Cardiol, Maastricht, Netherlands
[6] Liverpool Heart Chest Hosp, Inst Cardiovasc Med & Sci, Liverpool, Merseyside, England
[7] Uppsala Univ, Inst Med Sci, Dept Cardiol, Uppsala, Sweden
来源
EUROPACE | 2014年 / 16卷 / 11期
关键词
Cardiac implantable electronic devices; Pacemaker; Implantable Cardioverter; defibrillator; Leads; Malfunction; Recall; Extraction; Abandonment; EHRA survey; EP wire; EXTRACTION; FAILURE; SAFETY;
D O I
10.1093/europace/euu302
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this survey was to describe the different strategies regarding the management of malfunctioning and recalled pacemaker and defibrillator leads across Europe. A questionnaire has been designed to assess the current practice and physician's approach to the management of leads which are faulty, unnecessary, and/or recalled. Responses to the questionnaire were received from 34 hospitals-members of the European Heart Rhythm Association (EHRA) electrophysiology (EP) research network. The survey involved both very high and low volume implanting centres, with 85% of the responding centres performing lead extraction. The survey provides a panoramic view of operator's decision making in the field of malfunctioning, recalled, and redundant leads and outlines a common point of view on lead abandonment and factors influencing the decision about lead extraction. The main factors strongly influencing the decision making were patient's age (59%), the presence of the damaged leads (44%), and the lead dwelling time (44%). Regarding the lead abandonment, the main concern (61%) was the potential greater difficulty associated with lead extraction in the future. High volume extracting centres showed a greater propensity to removing the malfunctioning or recalled leads compared with low volume or non-extracting centres. This EP Wire survey gives a snapshot of the operators' approaches and options regarding redundant, malfunctioning, and recalled lead management and may form the basis for future prospective research on this topic.
引用
收藏
页码:1674 / 1678
页数:5
相关论文
共 19 条
  • [1] Comparison of outcomes in patients with abandoned versus extracted implantable cardioverter defibrillator leads
    Amelot, Mathieu
    Foucault, Anthony
    Scanu, Patrice
    Gomes, Sophie
    Champ-Rigot, Laure
    Pellissier, Arnaud
    Milliez, Paul
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2011, 104 (11) : 572 - 577
  • [2] ELECTRa (European Lead Extraction ConTRolled) Registry-Shedding light on transvenous lead extraction real-world practice in Europe
    Bongiorni M.G.
    Romano S.L.
    Kennergren C.
    Butter C.
    Deharo J.C.
    Kutarsky A.
    Rinaldi C.A.
    Maggioni A.P.
    Blomström-Lundqvist C.
    Auricchio A.
    [J]. Herzschrittmachertherapie + Elektrophysiologie, 2013, 24 (3) : 171 - 175
  • [3] Current practice in transvenous lead extraction: a European Heart Rhythm Association EP Network Survey
    Bongiorni, Maria Grazia
    Blomstrom-Lundqvist, Carina
    Kennergren, Charles
    Dagres, Nikolaos
    Pison, Laurent
    Svendsen, Jesper Hastrup
    Auricchio, Angelo
    [J]. EUROPACE, 2012, 14 (06): : 783 - 786
  • [4] Management of recalled implantable cardioverter-defibrillator leads at generator replacement: a decision analysis model for Fidelis leads
    Burri, Haran
    Combescure, Christophe
    [J]. EUROPACE, 2014, 16 (08): : 1210 - 1217
  • [5] Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper
    Deharo, J. C.
    Bongiorni, M. G.
    Rozkovec, A.
    Bracke, F.
    Defaye, P.
    Fernandez-Lozano, I.
    Golzio, P. G.
    Hansky, B.
    Kennergren, C.
    Manolis, A. S.
    Mitkowski, P.
    Platou, E. S.
    Love, C.
    Wilkoff, B.
    [J]. EUROPACE, 2012, 14 (01): : 124 - 134
  • [6] Safety of transvenous lead extraction according to centre volume: a systematic review andmeta-analysis
    Di Monaco, Antonio
    Pelargonio, Gemma
    Narducci, Maria Lucia
    Manzoli, Lamberto
    Boccia, Stefania
    Flacco, Maria Elena
    Capasso, Lorenzo
    Barone, Lucy
    Perna, Francesco
    Bencardino, Gianluigi
    Rio, Teresa
    Leo, Milena
    Di Biase, Luigi
    Santangeli, Pasquale
    Natale, Andrea
    Rebuzzi, Antonio Giuseppe
    Crea, Filippo
    [J]. EUROPACE, 2014, 16 (10): : 1496 - 1507
  • [7] Superior Vena Cava Defibrillator Coils Make Transvenous Lead Extraction More Challenging and Riskier
    Epstein, Laurence M.
    Love, Charles J.
    Wilkoff, Bruce L.
    Chung, Mina K.
    Hackler, Joseph W.
    Bongiorni, Maria Grazia
    Segreti, Luca
    Carrillo, Roger G.
    Baltodano, Pablo
    Fischer, Avi
    Kennergren, Charles
    Viklund, Roger
    Mittal, Suneet
    Arshad, Aysha
    Ellenbogen, Kenneth A.
    John, Roy M.
    Maytin, Melanie
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (09) : 987 - 989
  • [8] Failure of a novel silicone-polyurethane copolymer (Optim™) to prevent implantable cardioverter-defibrillator lead insulation abrasions
    Hauser, Robert G.
    Abdelhadi, Raed H.
    McGriff, Deepa M.
    Retel, Linda Kallinen
    [J]. EUROPACE, 2013, 15 (02): : 278 - 283
  • [9] Longevity of Sprint Fidelis Implantable Cardioverter-Defibrillator Leads and Risk Factors for Failure Implications for Patient Management
    Hauser, Robert G.
    Maisel, William H.
    Friedman, Paul A.
    Kallinen, Linda M.
    Mugglin, Andrew S.
    Kumar, Kapil
    Hodge, David O.
    Morrison, Thomas B.
    Hayes, David L.
    [J]. CIRCULATION, 2011, 123 (04) : 358 - U247
  • [10] Henrikson CA, 2013, CIRC-ARRHYTHMIA ELEC, V3, P409