Strontium adsorption and desorption reactions in model drinking water distribution systems

被引:5
作者
Gerke, Tammie L. [1 ]
Little, Brenda J. [3 ]
Luxton, Todd P. [4 ]
Scheckel, Kirk G. [4 ]
Maynard, J. Barry [2 ]
Szabo, Jeff G. [5 ]
机构
[1] Miami Univ, Dept Geol & Environm Earth Sci, Oxford, OH 45056 USA
[2] Univ Cincinnati, Dept Geol, Cincinnati, OH 45221 USA
[3] Naval Res Lab, Stennis Space Ctr, MS 39529 USA
[4] US EPA, ORD, NRMRL, LRPCD, Cincinnati, OH 45268 USA
[5] US EPA, NHSRC, WIPD, Cincinnati, OH 45268 USA
来源
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA | 2014年 / 63卷 / 06期
基金
加拿大自然科学与工程研究理事会;
关键词
calcium carbonate; drinking water distribution system; alpha-FeOOH; iron; strontium; XANES; RAY-ABSORPTION SPECTROSCOPY; NATURAL ORGANIC-MATTER; IRON CORROSION SCALES; ZERO CHARGE; INORGANIC CONTAMINANTS; PIPE CORROSION; RELEASE; CHLORINE; SORPTION; SURFACE;
D O I
10.2166/aqua.2014.075
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Divalent cationic strontium (Sr2+) adsorption to and desorption from iron corrosion products were examined in two model drinking water distribution systems (DWDS). One system was maintained with chlorine-disinfected drinking water and the other with the same water with secondary chloramine disinfection. Flow conditions simulated primary transmission lines (constant flow) and residential mains (periods of stagnation). Accumulation of Sr2+ to iron corrosion products in model DWDS was independent of disinfection type. Adsorption and desorption mechanisms are discussed. X-ray adsorption near edge structure (XANES) spectroscopy and linear combination fitting determined Sr2+ was primarily associated with iron oxyhydroxide corrosion products. At the end of the desorption study, the amount of Sr2+ remaining in iron corrosion products equilibrated to approximate levels observed at the end of the constant flow adsorption experiments. These results suggest that enhanced iron corrosion product loading of Sr2+ during stagnation could be short lived under constant flow conditions. Differences between adsorption and desorption based on disinfection type (chlorine versus chlorine plus chloramine) cannot be used to control Sr2+ desorption.
引用
收藏
页码:449 / 460
页数:12
相关论文
共 43 条
  • [31] The Chlorine Dilemma
    Sedlak, David L.
    von Gunten, Urs
    [J]. SCIENCE, 2011, 331 (6013) : 42 - 43
  • [32] Segre CU, 2000, AIP CONF PROC, V521, P419, DOI 10.1063/1.1291825
  • [33] Shaw B. W., 2012, DIVISION, P114
  • [34] SONTHEIMER H, 1981, J AM WATER WORKS ASS, V73, P572
  • [35] Corrosion in drinking water pipes: The importance of green rusts
    Swietlik, Joanna
    Raczyk-Stanislawiak, Urszula
    Piszora, Pawel
    Nawrocki, Jacek
    [J]. WATER RESEARCH, 2012, 46 (01) : 1 - 10
  • [36] Persistence and decontamination of surrogate radioisotopes in a model drinking water distribution system
    Szabo, Jeffrey G.
    Impellitteri, Christopher A.
    Govindaswamy, Shekar
    Hall, John S.
    [J]. WATER RESEARCH, 2009, 43 (20) : 5004 - 5014
  • [37] The role of rusts in corrosion and corrosion protection of iron and steel
    Tamura, Hiroki
    [J]. CORROSION SCIENCE, 2008, 50 (07) : 1872 - 1883
  • [38] Characteristics of iron corrosion scales established under blending of ground, surface, and saline waters and their impacts on iron release in the pipe distribution system
    Tang, ZJ
    Hong, SK
    Xiao, WZ
    Taylor, J
    [J]. CORROSION SCIENCE, 2006, 48 (02) : 322 - 342
  • [39] Effect of biofilm on cast iron pipe corrosion in drinking water distribution system: Corrosion scales characterization and microbial community structure investigation
    Teng, F.
    Guan, Y. T.
    Zhu, W. P.
    [J]. CORROSION SCIENCE, 2008, 50 (10) : 2816 - 2823
  • [40] Surface charge heterogeneity of kaolinite in aqueous suspension in comparison with montmorillonite
    Tombacz, Etelka
    Szekeres, Marta
    [J]. APPLIED CLAY SCIENCE, 2006, 34 (1-4) : 105 - 124