Micro-computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments

被引:15
|
作者
Miguens-Vila, Ramon [1 ]
Martin-Biedma, Benjamin [1 ]
De-Deus, Gustavo [2 ]
Belladonna, Felipe G. [2 ]
Pena-Lopez, Alejandro [3 ]
Castelo-Baz, Pablo [1 ]
机构
[1] Univ Santiago de Compostela, Santiago De Compostela, Galicia, Spain
[2] Fluminense Fed Univ, Niteroi, RJ, Brazil
[3] European Univ Madrid, Madrid, Spain
关键词
Curved root canals; dentinal defects; microcracks; micro?computed tomography; root canal preparation; SINGLE-FILE SYSTEMS; TREATED TEETH; UNIVERSAL; IRRIGATION;
D O I
10.1016/j.joen.2020.10.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of curved root canals using micro?computed tomographic analysis. Methods: Twenty-four human mandibular molars with curved roots were scanned in a micro?computed tomographic device using an isotropic resolution of 6.78 mm and randomly assigned into 1 of 3 experimental groups (n = 8) according to the root canal instrumentation system used (PTN, PTG, or WOG). Then, the root canals were prepared up to PTN X2, PTG F2, and WOG Primary instruments in the PTN, PTG, and WOG groups, respectively. After canal preparation, each specimen was scanned again. Pre-and postoperative cross-sectional images of the roots (N = 35,304) were analyzed to identify the presence of dentinal microcracks. Results: Overall, 26% of the images presented dentinal defects (n = 9188). Dentinal microcracks were observed in 24.6%, 26%, and 27.4% of the postinstrumentation images from the PTN, PTG, and WOG groups, respectively. However, all of these dentinal microcracks were already present in the corresponding preoperative images. No new microcracks were generated after the preparation of curved root canals of mandibular molars using the aforementioned systems. Conclusions: Root canal instrumentation with PTN, PTG, and WOG systems did not induce the formation of new dentinal microcracks. (J Endod 2021;47:309?314.)
引用
收藏
页码:309 / 314
页数:6
相关论文
共 50 条
  • [31] Comparative evaluation of fracture resistance of endodontically treated bicuspids instrumented with hand files, trunatomy, protaper next, protaper gold, and waveone - An In vitro study
    Nassar, Sulfia
    Shetty, Harish Kumar
    Nair, Prathap M. S.
    Gowri, Sree
    Jayaprakash, K.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 600 - 604
  • [32] Evaluation of the Canal Transportation and Centering Ratio at Different Levels of Simulated Curved Canals Prepared by OneShape, Protaper Next, Protaper Gold and TwoShape Nickel Titanium Rotary Files
    Jasim, Ahmed A.
    Al-Gharrawi, Hikmet A. Sh
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2019, 8 (08): : 91 - 97
  • [33] Shaping ability of rotatory or reciprocating instruments in curved canals: a micro-computed tomographic study
    Jardine, Alexander Pompermayer
    da Rosa, Ricardo Abreu
    Santini, Manuela Favarin
    Zaccara, Ivana Maria
    Reis So, Marcus Vinicius
    Poli Kopper, Patricia Maria
    BRAZILIAN ORAL RESEARCH, 2016, 30 (01):
  • [34] Micro-computed Tomographic Analysis of Apical Microcracks before and after Root Canal Preparation by Hand, Rotary, and Reciprocating Instruments at Different Working Lengths
    de Oliveira, Bruna Paloma
    Camara, Andrea Cruz
    Duarte, Daniel Amancio
    Heck, Richard John
    Dantas Antonino, Antonio Celso
    Aguian, Carlos Menezes
    JOURNAL OF ENDODONTICS, 2017, 43 (07) : 1143 - 1147
  • [35] Evaluation of XP-endo Shaper, Reciproc Blue, and ProTaper Universal NiTi Systems on Dentinal Microcrack Formation Using Micro-Computed Tomography
    Aksoy, Cagman
    Keris, Elif Yildizer
    Yaman, Sis Darendeliler
    Ocak, Mert
    Geneci, Ferhat
    Celik, Hakan Hamdi
    JOURNAL OF ENDODONTICS, 2019, 45 (03) : 338 - 342
  • [36] Efficacy of D-RaCe and ProTaper Universal Retreatment NiTi instruments and hand files in removing gutta-percha from curved root canals - a micro-computed tomography study
    Roedig, T.
    Hausdoerfer, T.
    Konietschke, F.
    Dullin, C.
    Hahn, W.
    Huelsmann, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (06) : 580 - 589
  • [37] Shaping ability of XP-endo Shaper and ProTaper Next in long oval-shaped canals: a micro-computed tomography study
    Velozo, C.
    Silva, S.
    Almeida, A.
    Romeiro, K.
    Vieira, B.
    Dantas, H.
    Sousa, F.
    De Albuquerque, D. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (07) : 998 - 1006
  • [38] Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study
    Topcuoglu, Hueseyin Sinan
    Duzgun, Salih
    Akpek, Firdevs
    Topcuoglu, Gamze
    SCANNING, 2016, 38 (06) : 585 - 590
  • [39] Shaping ability of WaveOne Gold and OneReci by using two apical sizes: a micro-computed tomographic assessment
    Ciftcioglu, Elif
    Keles, Ali
    Dincer, Gozde Akbal
    Ates, Melis Oya
    Kucukay, Enver Sedat
    PEERJ, 2023, 11
  • [40] Micro-Computed Tomographic Assessment of Microcrack Formation before and after Instrumentation of Curved Root Canals with Neoniti Rotary Files
    Zarean, Parichehr
    Oezcan, Mutlu
    Zarean, Paridokht
    Haghani, Seyed Omid
    Jahromi, Maryam Zare
    Husain, Nadin Al-Haj
    Khabiri, Masoud
    MATERIALS, 2022, 15 (09)