Experimental study on ablation of leiomyoma by combination high-intensity focused ultrasound and iodized oil in vitro

被引:1
|
作者
Liang, Zhi-Gang [1 ]
Gao, Yi [1 ]
Ren, Xiao-Yan [1 ]
Sun, Cui [1 ]
Gu, Heng-Fang [1 ]
Mou, Meng [1 ]
Xiao, Yan-Bing [1 ]
机构
[1] Zunyi Med Univ, Dept Gynaecol, Affiliated Hosp Maternal & Child Hlth Care, 287 Zhonghua Rd Honghuagang Dist, Zunyi 563000, Guizhou, Peoples R China
关键词
enhancement; high-intensity focused ultrasound; iodized oil; leiomyoma; HYPERECHO; LESIONS; CANCER; HYSTERECTOMY; CAVITATION; MECHANISMS; NECROSIS; IMAGES; LIVER; VIVO;
D O I
10.1111/jog.13407
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim: The aim of the current study was to investigate whether iodized oil (IO) enhances high-intensity focused ultrasound (HIFU) ablation of uterine leiomyoma and to determine the features of hyperechoic changes in the target region. Methods: Forty samples of uterine leiomyoma were randomly divided into an experimental group and a control group. In the experimental group, the leiomyoma was ablated by HIFU 30min after 1mL of iodized oil had been injected into the center of the myoma. The hyperechoic values and areas in the target region were observed by B-modal ultrasound after HIFU ablation. The samples were cut successively into slices and stained by triphenyltetrazolium chloride (TTC) solution within 1h after HIFU ablation. The diameters of TTC-non-stained areas were measured and tissues in the borderline of the TTC-stained and -non-stained areas were observed pathologically. All procedures in the control group were the same as those in the experimental group except IO was replaced by physiological saline. Results: The hyperechoic value in the target region in the experimental group was higher than that in the control group 4min after HIFU ablation (P<0.05). Hyperechoic areas in the target region as well as TTC-non-stained volumes in the experimental group were greater than those in the control group (P<0.05). Routine pathologic observation showed that coagulation necrosis of leiomyoma occurred in the target region in both groups. Conclusion: IO causes coagulation necrosis, enlarges tissue damage, and postpones the attenuation of hyperechoic changes in the target region when HIFU ablation is carried out for leiomyoma in vitro.
引用
收藏
页码:1578 / 1584
页数:7
相关论文
共 50 条
  • [31] High-intensity focused ultrasound ablation for advanced pancreatic cancer
    Zhu, Baorang
    Li, Jing
    Diao, Liyan
    Ma, Ke
    Fan, Yanna
    Yang, Wuwei
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (04) : 831 - 835
  • [32] Frequency considerations for deep ablation with high-intensity focused ultrasound: A simulation study
    Ellens, Nicholas
    Hynynen, Kullervo
    MEDICAL PHYSICS, 2015, 42 (08) : 4896 - 4910
  • [33] Comparative Study of Pulsed Versus Continuous High-Intensity Focused Ultrasound Ablation Using in vitro and in vivo Models
    Wang, Yanhao
    Wang, Qi
    Luo, Yong
    Jiang, Lu
    Zeng, Zihuan
    Gan, Lidan
    Chen, Jianli
    Han, Hongfei
    Zou, Jianzhong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (02) : 259 - 271
  • [34] High-Intensity Focused Ultrasound Ablation of Myocardium In Vivo and Instantaneous Biological Response
    Zheng, Minjuan
    Shentu, Weihui
    Chen, Dingzhang
    Sahn, David J.
    Zhou, Xiaodong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (09): : 1146 - 1153
  • [35] An in vitro and in vivo study on extracorporeal transducer optimization for high-intensity focused ultrasound to improve the safety and efficacy of breast tumor ablation
    Hong, Liu
    Zhang, Wendy
    Pan, Feibao
    Xiaobo, Gong
    Huang, Haoran
    You, Yaqing
    Deng, Lulu
    Wang, Zhibiao
    Zhang, Cai
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2023, 40 (01)
  • [36] A feasibility study of noninvasive ablation of ventricular tachycardia using high-intensity focused ultrasound
    Lu, Fei
    Huang, Wei
    Benditt, David G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (05) : 788 - 794
  • [37] TISSUE ABLATION IN BENIGN PROSTATIC HYPERPLASIA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    MADERSBACHER, S
    KRATZIK, C
    SZABO, N
    SUSANI, M
    VINGERS, L
    MARBERGER, M
    EUROPEAN UROLOGY, 1993, 23 : 39 - 43
  • [38] Septal Ablation Induced by Transthoracic High-Intensity Focused Ultrasound in Canines
    Rong, Shunkang
    Woo, Kamsang
    Zhou, Qi
    Zhu, Que
    Wu, Qi
    Wang, Qi
    Deng, Changming
    Liu, Dichuan
    Yang, Gang
    Jiang, Yonghong
    Wang, Zhibiao
    Huang, Jing
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (10) : 1228 - 1234
  • [39] High-intensity focused ultrasound ablation of liver tumors in difficult locations
    Tsang, Simon H.
    Ma, Ka Wing
    She, Wong Hoi
    Chu, Ferdinand
    Lau, Vince
    Lam, Shuk Wan
    Cheung, Tan To
    Lo, Chung Mau
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (02) : 56 - 64
  • [40] Effect of echo-guided high-intensity focused ultrasound ablation on localized experimental tumors
    Sasaki, Kazuaki
    Medan, Mohamed S.
    Azuma, Takashi
    Kawabata, Ken-ichi
    Shimoda, Minoru
    Umemura, Shin-ichiro
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2006, 68 (10) : 1069 - 1074