Respiratory signal prediction based on adaptive boosting and multi-layer perceptron neural network

被引:35
作者
Sun, W. Z. [1 ,2 ]
Jiang, M. Y. [1 ]
Ren, L. [2 ]
Dang, J. [3 ]
You, T. [3 ]
Yin, F-F [2 ]
机构
[1] Shandong Univ, Inst Informat Sci & Engn, Jinan, Shandong, Peoples R China
[2] Duke Univ, Dept Radiat Oncol, Ctr Canc, Durham, NC 27708 USA
[3] Jiangsu Univ, Dept Radiat Oncol, Affiliated Hosp, Zhenjiang, Jiangsu, Peoples R China
基金
美国国家卫生研究院;
关键词
radiation therapy; dynamic tracking; artificial neural network; respiratory motion prediction; multi-layer perceptron neural network; BREATH-HOLD; TUMOR TRACKING; MOTION; MODEL; LUNG; AVERAGE; FILTER;
D O I
10.1088/1361-6560/aa7cd4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To improve the prediction accuracy of respiratory signals using adaptive boosting and multi-layer perceptron neural network (ADMLP-NN) for gated treatment of moving target in radiation therapy. The respiratory signals acquired using a real-time position management (RPM) device from 138 previous 4DCT scans were retrospectively used in this study. The ADMLP-NN was composed of several artificial neural networks (ANNs) which were used as weaker predictors to compose a stronger predictor. The respiratory signal was initially smoothed using a Savitzky-Golay finite impulse response smoothing filter (S-G filter). Then, several similar multi-layer perceptron neural networks (MLP-NNs) were configured to estimate future respiratory signal position from its previous positions. Finally, an adaptive boosting (Adaboost) decision algorithm was used to set weights for each MLP-NN based on the sample prediction error of each MLP-NN. Two prediction methods, MLP-NN and ADMLP-NN (MLP-NN plus adaptive boosting), were evaluated by calculating correlation coefficient and root-mean-square-error between true and predicted signals. For predicting 500ms ahead of prediction, average correlation coefficients were improved from 0.83 (MLP-NN method) to 0.89 (ADMLP-NN method). The average of root-mean-square-error (relative unit) for 500ms ahead of prediction using ADMLP-NN were reduced by 27.9%, compared to those using MLP-NN. The preliminary results demonstrate that the ADMLP-NN respiratory prediction method is more accurate than the MLP-NN method and can improve the respiration prediction accuracy.
引用
收藏
页码:6822 / 6835
页数:14
相关论文
共 29 条
[1]   A moving-average filter based hybrid ARIMA-ANN model for forecasting time series data [J].
Babu, C. Narendra ;
Reddy, B. Eswara .
APPLIED SOFT COMPUTING, 2014, 23 :27-38
[2]   Estimation of error in maximal intensity projection-based internal target volume of lung tumors: A simulation and comparison study using dynamic magnetic resonance imaging [J].
Cai, Jing ;
Read, Paul W. ;
Baisden, Joseph M. ;
Larner, James M. ;
Benedict, Stanley H. ;
Sheng, Ke .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03) :895-902
[3]   Investigation of sliced body volume (SBV) as respiratory surrogate [J].
Cai, Jing ;
Chang, Zheng ;
O'Daniel, Jennifer ;
Yoo, Sua ;
Ge, Hong ;
Kelsey, Christopher ;
Yin, Fang-Fang .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01) :71-80
[4]   Lesion discrimination with breath-hold hepatic diffusion-weighted imaging: A meta-analysis [J].
Chen, Zhi-Guang ;
Xu, Li ;
Zhang, Si-Wei ;
Huang, Yan ;
Pan, Rui-Huan .
WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (05) :1621-1627
[5]   Predicting the outcome of respiratory motion prediction [J].
Ernst, Floris ;
Schlaefer, Alexander ;
Schweikard, Achim .
MEDICAL PHYSICS, 2011, 38 (10) :5569-5581
[6]   Hybrid Kalman Filters for Very Short-Term Load Forecasting and Prediction Interval Estimation [J].
Guan, Che ;
Luh, Peter B. ;
Michel, Laurent D. ;
Chi, Zhiyi .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) :3806-3817
[7]   Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator [J].
Hansen, Rune ;
Ravkilde, Thomas ;
Worm, Esben Schjodt ;
Toftegaard, Jakob ;
Grau, Cai ;
Macek, Kristijan ;
Poulsen, Per Rugaard .
MEDICAL PHYSICS, 2016, 43 (05) :2387-2398
[8]   Real-time prediction of respiratory motion based on a local dynamic model in an augmented space [J].
Hong, S-M ;
Jung, B-H ;
Ruan, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) :1775-1789
[9]   A study on the dosimetric accuracy of treatment planning for stereotactic body radiation therapy of lung cancer using average and maximum intensity projection images [J].
Huang, Long ;
Park, Kwangyoul ;
Boike, Thomas ;
Lee, Pam ;
Papiez, Lech ;
Solberg, Timothy ;
Ding, Chuxiong ;
Timmerman, Robert D. .
RADIOTHERAPY AND ONCOLOGY, 2010, 96 (01) :48-54
[10]   Comparison of breath-hold and free-breathing positions of an external fiducial by analysis of respiratory traces [J].
Hunjan, Sandeep ;
Starkschall, George ;
Rosen, Isaac ;
Prado, Karl ;
Tolani, Naresh ;
Balter, Peter .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03) :34-42