Measurement of serum creatinine levels with liquid chromatography-tandem mass spectrometry: comparison with Jaffe and enzymatic methods

被引:6
|
作者
Yildirimel, Mehmet [1 ]
Atalar, Mehmet Nuri [2 ]
Abusoglu, Sedat [1 ]
Onmaz, Duygu Eryavuz [1 ]
Sivrikaya, Abdullah [1 ]
Abusoglu, Gulsum [3 ]
Unlu, Ali [1 ]
机构
[1] Selcuk Univ, Dept Biochem, Fac Med, Konya, Turkey
[2] Igdir Univ, Fac Sci & Letters, Dept Biochem, Igdir, Turkey
[3] Selcuk Univ Vocat, Dept Med Lab Tech, Sch Hlth, Konya, Turkey
来源
TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI | 2021年 / 46卷 / 03期
关键词
comparison; creatinine; enzymatic; Jaffe; LC-MS/MS; LC-MS/MS; VALIDATION; URINE;
D O I
10.1515/tjb-2019-0357
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Objectives: Our aim was to validate a mass spectrometric creatinine method and compare this method with Jaffe and enzymatic serum creatinine methods. Methods: 90 samples were included. The levels were classified into three groups according to serum creatinine results as Group 1: Lower (n=30) (0.16-0.59 mg/dL), Group 2: Normal (n=30) (0.62-1.18 mg/dL) and Group 3: Higher (n=30) (1.33-3.88 mg/dL). Jaffe and enzymatic creatinine measurements were performed on the Beckman Coulter AU5800 autoanalyzer. Results: Serum creatinine was linear from 0.039 up to 10 mg/dL, CV and bias values were ranged between 1.9-3.8% and 2-15%. Correlation coefficients were 0.990 (95% confidence interval 0.984-0.993), 0.992 (95% confidence interval 0.988-0.995) and 0.994 (95% confidence interval 0.991-0.996) for LC-MS/MS-Enzymatic, LC-MS/MS-Jaffe and Enzymatic-Jaffe, respectively. Conclusions: Although, Jaffe method for serum creatinine measurement is still much more practical and cheap, so in use for routine practice, tandem mass spectrometric detection of serum creatinine can be used as an accurate and specific method for verification of discordant clinical results, existence of possible interferences and serum levels under 0.5 mg/dL creatinine results such as pediatric or pregnant populations.
引用
收藏
页码:263 / 271
页数:9
相关论文
共 50 条
  • [1] Comparison of Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry Methods in the Measurement of Serum Androstenedione Levels
    Yucel, Kamile
    Abusoglu, Sedat
    Unlu, Ali
    CLINICAL LABORATORY, 2018, 64 (1-2) : 69 - 75
  • [2] Creatinine measurements in 24 h urine by liquid chromatography-tandem mass spectrometry
    Park, Eun-Kee
    Watanabe, Takaho
    Gee, Shirley J.
    Schenker, Marc B.
    Hammock, Bruce D.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (02) : 333 - 336
  • [3] Measurement of marine osmolytes in mammalian serum by liquid chromatography-tandem mass spectrometry
    Lenky, Crystal C.
    McEntyre, Christopher J.
    Lever, Michael
    ANALYTICAL BIOCHEMISTRY, 2012, 420 (01) : 7 - 12
  • [4] Simultaneous determination of creatinine and uric acid in urine by liquid chromatography-tandem mass spectrometry with polarity switching electrospray ionization
    Kwon, Woonyong
    Kim, Jin Young
    Suh, SungIll
    In, Moon Kyo
    FORENSIC SCIENCE INTERNATIONAL, 2012, 221 (1-3) : 57 - 64
  • [5] Comparison of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods to quantify α-tocopherol and α-tocopherolquinone levels in human plasma
    Mottier, P
    Gremaud, E
    Guy, PA
    Turesky, RJ
    ANALYTICAL BIOCHEMISTRY, 2002, 301 (01) : 128 - 135
  • [6] Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Stenman, Ulf-Hakan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 113 - 118
  • [7] Determination of serum amantadine by liquid chromatography-tandem mass spectrometry
    Arndt, T
    Guessregen, B
    Hohl, A
    Reis, J
    CLINICA CHIMICA ACTA, 2005, 359 (1-2) : 125 - 131
  • [8] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01) : 50 - 57
  • [9] Serum Creatinine Determined by Jaffe, Enzymatic Method, and Isotope Dilution-Liquid Chromatography-Mass Spectrometry in Patients Under Hemodialysis
    Liu, Wen-Sheng
    Chung, Yu-Ting
    Yang, Chih-Yu
    Lin, Chih-Ching
    Tsai, Kun-Hung
    Yang, Wu-Chang
    Chen, Tzen-Wen
    Lai, Yen-Ting
    Li, Szu-Yuan
    Liu, Tsung-Yun
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2012, 26 (03) : 206 - 214
  • [10] Liquid chromatography-tandem mass spectrometry measurement of 26 steroid hormones in human serum and plasma samples
    Jia, Yongjuan
    Liu, Xingli
    Xu, Li
    Zhao, Jinbao
    Ni, Junjun
    Zhang, Yuanyuan
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (12) : 2358 - 2370