Effect of saliva decontamination protocol on the adhesion to dentin with a universal adhesive

被引:2
作者
Chasqueira, Ana Filipa [1 ]
Luis, Joana [1 ]
Portugal, Jaime [1 ]
机构
[1] Univ Lisbon, Fac Med Dentaria, Dept Biomat, Lisbon, Portugal
来源
REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL | 2019年 / 60卷 / 02期
关键词
Decontamination; Dentin bonding; Saliva contamination; Shear bond strength; Universal adhesive; SELF-ETCHING ADHESIVES; SHEAR BOND STRENGTH; SINGLE-BOTTLE ADHESIVES; INTERFACIAL MORPHOLOGY; RESIN HYDROPHILICITY; CONTAMINATION; ENAMEL; COMPOSITE; SYSTEMS; BLOOD;
D O I
10.24873/j.rpemd.2019.09.452
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the influence and effectiveness of the salivary decontamination protocol after polymerization of a universal adhesive on dentin adhesive strength, after 24 hours and 6 months of ageing. Methods: Fifty intact molars were sectioned in order to obtain two slices of dentin from each tooth. In all specimens except the control group (C - no contamination), after applying and light-curing the adhesive system (Scotchbond Universal), the adhesion surface was contaminated with human saliva, and was then subjected to a decontamination method that differed between groups (W - decontamination with water; W+A - decontamination with water and reapplication of adhesive; E - decontamination with ethanol; E+A - decontamination with ethanol and reapplication of adhesive). Shearbond strength was tested at 24 hours and 6 months of aging, until fracture, and the failure mode was observed. Data were statistically analyzed using non-parametric Mann-Whitney and Kruskal-Wallis tests (alpha=0.05). Results: At 24 hours of aging, the decontaminant (p=0.289) and the reapplication of the adhesive (p=0.072) did not influence the adhesive strength values, and all contaminated groups obtained significantly (p<0.05) lower adhesive strength values than the control group. At 6 months, the reapplication of the adhesive (W+A and E+A) provided increased adhesion values (p=0.001), but no differences were observed between the decontaminants (p=0.314). Only the W+A group yielded a statistically (p=0.376) similar value to the control group. Conclusion: When there is salivary contamination of the adhesion area after polymerization of the universal adhesive tested, water decontamination should be performed followed by a reapplication of the adhesive. (C) 2019 Sociedade Portuguesa de Estomatologia e Medicina Dentaria. Published by SPEMD.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 47 条
[1]  
Abdalla AI, 1998, AM J DENT, V11, P281
[2]  
An H, 2008, EUROPEAN J DENT, V2, P86
[3]   Adhesion to tooth structure: A critical review of "macro" test methods [J].
Braga, Roberto R. ;
Meira, Josete B. C. ;
Boaro, Leticia C. C. ;
Xavier, Tathy A. .
DENTAL MATERIALS, 2010, 26 (02) :E38-E49
[4]   Influence of decontamination procedures on shear forces after contamination with blood or saliva [J].
Brauchli, Lorenz ;
Eichenberger, Martina ;
Steineck, Markus ;
Wichelhaus, Andrea .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (04) :435-441
[5]  
Chasqueira AF, 2013, J APPL BIOMATER FUNC, V11, P117, DOI [10.5301/JABFM.5000156, 10.5301/jabfm.5000156]
[6]   Adhesion of dental sealants to enamel with self-etching adhesives in salivary contamination conditions: Influence of the light curing protocol [J].
Chasqueira, Filipa ;
Portugal, Jaime ;
Arantes e Oliveira, Sofia Santos ;
Lopes, Luis Pires .
REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2011, 52 (01) :2-6
[7]  
Darabi Farideh, 2012, Dent Res J (Isfahan), V9, P399
[8]   Effects of saliva contamination on resin-resin bond strength [J].
Eiriksson, SO ;
Pereira, PNR ;
Swift, EJ ;
Heymann, HO ;
Sigurdsson, A .
DENTAL MATERIALS, 2004, 20 (01) :37-44
[9]  
ElKalla IH, 1997, AM J DENT, V10, P83
[10]  
Elkassas Dina, 2016, Eur J Dent, V10, P327, DOI 10.4103/1305-7456.184159