In vivo biostability of a poly(carbonate-urea)urethane graft

被引:119
|
作者
Seifalian, AM [1 ]
Salacinski, HJ
Tiwari, A
Edwards, A
Bowald, S
Hamilton, G
机构
[1] UCL, Royal Free Hosp, Sch Med, Tissue Engn Ctr,Dept Surg, London NW3 2QG, England
[2] Credent Vasc Technol Ltd, Wrexham LL5 EA, Clwyd, Wales
[3] Univ Uppsala Hosp, Uppsala, Sweden
关键词
D O I
10.1016/S0142-9612(02)00608-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In peripheral and coronary bypass surgery, the patency of prosthetic grafts is inferior to autologous vein, mainly due to intimal hyperplasia caused in part by compliance mismatch between rigid graft and elastic host artery. We have developed a compliant poly(carbonate-urea)urethane vascular graft "MyoLink(TM)" which was biostable in vitro degradation studies. To further investigate the biostability of this material, we report a long-term in vivo study on 8 beagle dogs (15 +/- 3 kg) implanted with this graft (ID 5 mm) in the aorta-iliac position; three grafts were harvested at 18 months to assess short-term biodegradation, with one animal having died from an unrelated infection. The 4 remaining grafts were harvested at 36 months for analysis by: (1) histology, (2) compliance measurements and (3) environmental scanning electron microscopy (ESEM); gel permeation chromatography (GPC); attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and radial tensile strength analysis. There was no infection or inflammation of the grafts or surrounding tissues. Histological analysis showed a well-developed neointima but only at the distal anastomosis. There were no significant differences in compliance pre- and post-implantation and no evidence of material curvature, radial expansion or chemical breakdown, ESEM and GPC showed no signs of degradation. Peak height analysis with ATR-FTIR of the 1740 cm(-1) (C = O of carbonate) and 1253 cm(-1) bands (C-O-C of CO-O-C) showed a loss of carbonate carbonyl but was not statistically significant. Radial tensile strength remained within batch release specifications. This polyurethane graft retains its compliance post-implantation, whilst exhibiting only a minor hydrolysis of the amorphous segment, confirming its biostability in vivo up to 3 years. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2549 / 2557
页数:9
相关论文
共 50 条
  • [41] Evaluation of Poly (Carbonate-Urethane) Urea (PCUU) Scaffolds for Urinary Bladder Tissue Engineering
    Srikanth Sivaraman
    Nicholas Amoroso
    Xinzhu Gu
    J. Todd Purves
    Francis M. Hughes
    William R. Wagner
    Jiro Nagatomi
    Annals of Biomedical Engineering, 2019, 47 : 891 - 901
  • [42] Synthesis and characterization of alternating poly(amide urea)s and poly(amide urethane urethane)s from ε-caprolactam, diamines, and diphenyl carbonate or ethylene carbonate -: art. no. 068
    Ubaghs, L
    Sharma, B
    Keul, H
    Höcker, H
    Loontjens, T
    van Benthem, R
    E-POLYMERS, 2003,
  • [44] Synthesis and properties of poly(carbonate-urethane) consisting of alternating carbonate and urethane moieties
    Ochiai, B
    Amemiya, H
    Yamazaki, H
    Endo, T
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2006, 44 (09) : 2802 - 2808
  • [45] The effect of urethane and urea content on the gas permeation properties of poly(urethane-urea) membranes
    Sadeghi, Morteza
    Semsarzadeh, Mohammad Ali
    Barikani, Mehdi
    Ghalei, Behnam
    JOURNAL OF MEMBRANE SCIENCE, 2010, 354 (1-2) : 40 - 47
  • [46] Assessment of aliphatic poly(ester-carbonate-urea-urethane)s potential as materials for biomedical application
    Joanna Mystkowska
    Magdalena Mazurek-Budzyńska
    Ewelina Piktel
    Katarzyna Niemirowicz
    Wojciech Karalus
    Piotr Deptuła
    Katarzyna Pogoda
    Dawid Łysik
    Jan Ryszard Dąbrowski
    Gabriel Rokicki
    Robert Bucki
    Journal of Polymer Research, 2017, 24
  • [47] Influence of the hard segments content on the properties of electrospun aliphatic poly(carbonate-urethane-urea)s
    Rolinska, Karolina
    Bakhshi, Hadi
    Balk, Maria
    Parzuchowski, Pawel
    Mazurek-Budzynska, Magdalena
    RSC ADVANCES, 2024, 14 (22) : 15766 - 15775
  • [48] Assessment of aliphatic poly(ester-carbonate-urea-urethane)s potential as materials for biomedical application
    Mystkowska, Joanna
    Mazurek-Budzynska, Magdalena
    Piktel, Ewelina
    Niemirowicz, Katarzyna
    Karalus, Wojciech
    Deptula, Piotr
    Pogoda, Katarzyna
    Lysik, Dawid
    Dabrowski, Jan Ryszard
    Rokicki, Gabriel
    Bucki, Robert
    JOURNAL OF POLYMER RESEARCH, 2017, 24 (09)
  • [49] Tailoring the degradation kinetics of poly(ester carbonate urethane)urea thermoplastic elastomers for tissue engineering scaffolds
    Hong, Yi
    Guan, Jianjun
    Fujimoto, Kazuro L.
    Hashizume, Ryotaro
    Pelinescu, Anca L.
    Wagner, William R.
    BIOMATERIALS, 2010, 31 (15) : 4249 - 4258
  • [50] Poly(siloxane)-block-poly(urea urethane) copolymers
    Raigorodskii, IM
    Kopylov, VM
    Kireev, VV
    Vitsenovskaya, EV
    Travkin, AE
    POLYMER SCIENCE SERIES B, 2002, 44 (9-10) : 266 - 270