In vivo biostability of a poly(carbonate-urea)urethane graft

被引:119
|
作者
Seifalian, AM [1 ]
Salacinski, HJ
Tiwari, A
Edwards, A
Bowald, S
Hamilton, G
机构
[1] UCL, Royal Free Hosp, Sch Med, Tissue Engn Ctr,Dept Surg, London NW3 2QG, England
[2] Credent Vasc Technol Ltd, Wrexham LL5 EA, Clwyd, Wales
[3] Univ Uppsala Hosp, Uppsala, Sweden
关键词
D O I
10.1016/S0142-9612(02)00608-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In peripheral and coronary bypass surgery, the patency of prosthetic grafts is inferior to autologous vein, mainly due to intimal hyperplasia caused in part by compliance mismatch between rigid graft and elastic host artery. We have developed a compliant poly(carbonate-urea)urethane vascular graft "MyoLink(TM)" which was biostable in vitro degradation studies. To further investigate the biostability of this material, we report a long-term in vivo study on 8 beagle dogs (15 +/- 3 kg) implanted with this graft (ID 5 mm) in the aorta-iliac position; three grafts were harvested at 18 months to assess short-term biodegradation, with one animal having died from an unrelated infection. The 4 remaining grafts were harvested at 36 months for analysis by: (1) histology, (2) compliance measurements and (3) environmental scanning electron microscopy (ESEM); gel permeation chromatography (GPC); attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and radial tensile strength analysis. There was no infection or inflammation of the grafts or surrounding tissues. Histological analysis showed a well-developed neointima but only at the distal anastomosis. There were no significant differences in compliance pre- and post-implantation and no evidence of material curvature, radial expansion or chemical breakdown, ESEM and GPC showed no signs of degradation. Peak height analysis with ATR-FTIR of the 1740 cm(-1) (C = O of carbonate) and 1253 cm(-1) bands (C-O-C of CO-O-C) showed a loss of carbonate carbonyl but was not statistically significant. Radial tensile strength remained within batch release specifications. This polyurethane graft retains its compliance post-implantation, whilst exhibiting only a minor hydrolysis of the amorphous segment, confirming its biostability in vivo up to 3 years. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2549 / 2557
页数:9
相关论文
共 50 条
  • [31] Poly(urethane-urea)s based on the oligo-carbonate-diols prepared by the use of ethylene carbonate
    Rokicki, G
    Kozakiewicz, J
    Pawlowski, P
    Przybylski, J
    PRZEMYSL CHEMICZNY, 2003, 82 (8-9): : 953 - 955
  • [32] In vitro degradation and in vivo biocompatibility study of a new linear poly(urethane urea)
    Asplund, Basse
    Aulin, Cecilia
    Bowden, Tim
    Eriksson, Niklas
    Mathisen, Torbjoern
    Bjursten, Lars-Magnus
    Hilborn, Joens
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (01) : 45 - 55
  • [33] In-vivo degradation of poly(carbonate-urethane) based spine implants
    Cipriani, E.
    Bracco, P.
    Kurtz, S. M.
    Costa, L.
    Zanetti, M.
    POLYMER DEGRADATION AND STABILITY, 2013, 98 (06) : 1225 - 1235
  • [34] On imparting radiopacity to a poly(urethane urea)
    James, Nirmala R.
    Jayakrishnan, A.
    BIOMATERIALS, 2007, 28 (21) : 3182 - 3187
  • [35] Enzymatic degradation of poly(ether urethane) and poly(carbonate urethane) by cholesterol esterase
    Christenson, EM
    Patel, S
    Anderson, JM
    Hiltner, A
    BIOMATERIALS, 2006, 27 (21) : 3920 - 3926
  • [36] Chemical and physical characterization of a novel poly(carbonate urea) urethane surface with protein crosslinker sites
    Harvard Medical Sch, Boston, United States
    J Biomater Appl, 2 ([d]100-120):
  • [37] Chemical and physical characterization of a novel poly(carbonate urea) urethane surface with protein crosslinker sites
    Phaneuf, MD
    Quist, WC
    LoGerfo, FW
    Szycher, M
    Dempsey, DJ
    Bide, MJ
    JOURNAL OF BIOMATERIALS APPLICATIONS, 1997, 12 (02) : 100 - 120
  • [38] The effect of strain state on the biostability of a poly(etherurethane urea) elastomer
    Schubert, MA
    Wiggins, MJ
    Anderson, JM
    Hiltner, A
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1997, 35 (03): : 319 - 328
  • [39] Evaluation of Poly (carbonate-urethane) Urea (pcuu) as a Urinary Bladder Tissue Engineering Scaffold
    Sivaraman, S.
    Ambrose, C.
    Gu, X.
    Todd, P.
    Hughes, F. M.
    Wagner, W.
    Nagatomi, J.
    TISSUE ENGINEERING PART A, 2015, 21 : S173 - S174
  • [40] Evaluation of Poly (Carbonate-Urethane) Urea (PCUU) Scaffolds for Urinary Bladder Tissue Engineering
    Sivaraman, Srikanth
    Amoroso, Nicholas
    Gu, Xinzhu
    Purves, J. Todd
    Hughes, Francis M., Jr.
    Wagner, William R.
    Nagatomi, Jiro
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (03) : 891 - 901