In vivo biostability of a poly(carbonate-urea)urethane graft

被引:119
|
作者
Seifalian, AM [1 ]
Salacinski, HJ
Tiwari, A
Edwards, A
Bowald, S
Hamilton, G
机构
[1] UCL, Royal Free Hosp, Sch Med, Tissue Engn Ctr,Dept Surg, London NW3 2QG, England
[2] Credent Vasc Technol Ltd, Wrexham LL5 EA, Clwyd, Wales
[3] Univ Uppsala Hosp, Uppsala, Sweden
关键词
D O I
10.1016/S0142-9612(02)00608-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In peripheral and coronary bypass surgery, the patency of prosthetic grafts is inferior to autologous vein, mainly due to intimal hyperplasia caused in part by compliance mismatch between rigid graft and elastic host artery. We have developed a compliant poly(carbonate-urea)urethane vascular graft "MyoLink(TM)" which was biostable in vitro degradation studies. To further investigate the biostability of this material, we report a long-term in vivo study on 8 beagle dogs (15 +/- 3 kg) implanted with this graft (ID 5 mm) in the aorta-iliac position; three grafts were harvested at 18 months to assess short-term biodegradation, with one animal having died from an unrelated infection. The 4 remaining grafts were harvested at 36 months for analysis by: (1) histology, (2) compliance measurements and (3) environmental scanning electron microscopy (ESEM); gel permeation chromatography (GPC); attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and radial tensile strength analysis. There was no infection or inflammation of the grafts or surrounding tissues. Histological analysis showed a well-developed neointima but only at the distal anastomosis. There were no significant differences in compliance pre- and post-implantation and no evidence of material curvature, radial expansion or chemical breakdown, ESEM and GPC showed no signs of degradation. Peak height analysis with ATR-FTIR of the 1740 cm(-1) (C = O of carbonate) and 1253 cm(-1) bands (C-O-C of CO-O-C) showed a loss of carbonate carbonyl but was not statistically significant. Radial tensile strength remained within batch release specifications. This polyurethane graft retains its compliance post-implantation, whilst exhibiting only a minor hydrolysis of the amorphous segment, confirming its biostability in vivo up to 3 years. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2549 / 2557
页数:9
相关论文
共 50 条
  • [1] Tissue-engineering of a novel poly(carbonate-urea) urethane vascular graft MyoLink®
    Krijgsman, B
    Salacinski, HJ
    Punshon, G
    Seifalian, AM
    Hamilton, G
    BRITISH JOURNAL OF SURGERY, 2001, 88 : 16 - 16
  • [2] Tissue-engineering of a novel poly(carbonate-urea)urethane vascular graft "MyoLinK®"
    Punshon, G
    Seifalian, AM
    Salacinski, HJ
    Krigsman, B
    Hamilton, G
    FASEB JOURNAL, 2001, 15 (05): : A1129 - A1129
  • [3] Optimal endothelialisation of a new compliant poly(carbonate-urea)urethane vascular graft with effect of physiological shear stress
    Salacinski, HJ
    Tai, NR
    Punshon, G
    Giudiceandrea, A
    Hamilton, G
    Seifalian, AM
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (04) : 342 - 352
  • [4] In vitro stability of a novel compliant poly(carbonate-urea) urethane to oxidative and hydrolytic stress
    Salacinski, HJ
    Tai, NR
    Carson, RJ
    Edwards, A
    Hamilton, G
    Seifalian, AM
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 59 (02): : 207 - 218
  • [5] Engineering a bioartificial liver: optimisation of hepatocyte seeding in poly(carbonate-urea) urethane conduits
    Punshon, G
    Salacinski, H
    Seifalian, AM
    Davidson, BR
    FASEB JOURNAL, 2003, 17 (04): : A270 - A271
  • [6] Surface modification of poly(ether urethane urea) with modified dehydroepiandrosterone for improved in vivo biostability
    Christenson, EM
    Wiggins, MJ
    Anderson, JM
    Hiltner, A
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 73A (01) : 108 - 115
  • [7] Surface functionalization and grafting of heparin and/or rgd by an aqueous-based process to a poly(carbonate-urea)urethane cardiovascular graft for cellular engineering applications
    Salacinski, HJ
    Hamilton, G
    Seifalian, AM
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (03) : 688 - 697
  • [8] Polyhedral oligomeric silsesquioxane poly(Carbonate-Urea) urethane (POSS-PCU): Applications in nanotechnology and regenerative medicine
    Tan, Aaron
    Farhatnia, Yasmin
    Seifalian, Alexander M.
    Critical Reviews in Biomedical Engineering, 2014, 41 (06) : 495 - 513
  • [9] Hybrid bypass graft made from compliant poly(carbonate-urea)urethane scaffold, human smooth muscle and endothelial cells from the same patient
    Rashid, ST
    Salacinski, HJ
    Button, MJC
    Tohill, M
    Fuller, B
    Seifalian, AA
    Hamilton, G
    BRITISH JOURNAL OF SURGERY, 2005, 92 (10) : 1323 - 1323
  • [10] Incorporation of a lauric acid-conjugated GRGDS peptide directly into the matrix of a poly(carbonate-urea)urethane polymer for use in cardiovascular bypass graft applications
    Kidane, Asmeret G.
    Punshon, Geoffrey
    Salacinski, Henryk J.
    Ramesh, Bala
    Dooley, Audrey
    Olbrich, Michael
    Heitz, Johannes
    Hamilton, George
    Seifalian, Alexander M.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 79A (03) : 606 - 617