An innovative negative stiffness-inerter hybrid control device toward seismic-resilient structures

被引:11
作者
Kiran, K. K. [1 ]
Farsangi, Ehsan Noroozinejad [2 ]
Gharehbaghi, Vahidreza [2 ]
机构
[1] SJB Inst Technol, Bangalore, Karnataka, India
[2] Univ British Columbia, Dept Civil Engn, Vancouver, BC, Canada
基金
英国科研创新办公室;
关键词
Seismic base isolation; Inerter; Negative stiffness; Tuned inerter negative stiffness; Stationery excitation; Resilience; TUNED MASS-DAMPER; OPTIMAL-DESIGN; OPTIMUM PARAMETERS; VIBRATION; PERFORMANCE; PREDICTION; SYSTEMS;
D O I
10.1007/s41062-022-00904-x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To improve structure control efficiency, both inerter and negative stiffness elements can be employed. In this study, an innovative combination of negative stiffness and an inerter control mechanism is used to protect a structure under severe seismic loadings. To this end, the numerical analysis determines the tuning frequency ratio and optimum damping of white noise stationary and earthquake excitation filtered white noise acting on a base-isolated structure with a tuned inerter negative stiffness damper. The criteria for the optimum parameter are to maximize the energy dissipation index, the relative displacement of the mean square minimization, and the absolute acceleration of the isolated structure. Dynamic system applications are utilized to derive the tuning frequency and TINSD damping for white noise excitation via explicit curve fitting equations. For the proposed empirical expressions, the base-isolated structure with supplementary TINSD device design is determined to have less inaccuracy. Next, a comparison is made between non-stationary seismic excitations acting on the bare and TINSD base-isolated structures. Accordingly, base-isolated structure response reduction in displacement and acceleration with TINSD by optimum parameter is observed with a rise in greater mass ratio. This study proves that under broadband earthquake excitations, the initial optimal design is found to be effective for bearing displacement of a base-isolated structure with TINSD.
引用
收藏
页数:20
相关论文
共 51 条
[1]   Optimum parameters of tuned mass damper for damped main system [J].
Bakre, S. V. ;
Jangid, R. S. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (03) :448-470
[2]   Applications of Nonlinearity in Passive Vibration Control: A Review [J].
Balaji, P. S. ;
Karthik SelvaKumar, K. .
JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2021, 9 (02) :183-213
[3]   Optimal design for high-performance passive dynamic vibration absorbers under random vibration [J].
Barredo, Eduardo ;
Mendoza Larios, G. ;
Mayen, Jan ;
Flores-Hernandez, A. A. ;
Colin, Jorge ;
Arias Montiel, M. .
ENGINEERING STRUCTURES, 2019, 195 :469-489
[4]   A unified analysis of negative stiffness dampers and inerter-based absorbers for multimode cable vibration control [J].
Chen, Lin ;
Nagarajaiah, Satish ;
Sun, Limin .
JOURNAL OF SOUND AND VIBRATION, 2021, 494
[5]   Influence of inerter on natural frequencies of vibration systems [J].
Chen, Michael Z. Q. ;
Hu, Yinlong ;
Huang, Lixi ;
Chen, Guanrong .
JOURNAL OF SOUND AND VIBRATION, 2014, 333 (07) :1874-1887
[6]   Impact of soil-structure interaction on structures with inerter system [J].
Chen, Qingjun ;
Zhao, Zhipeng ;
Zhang, Ruifu ;
Pan, Chao .
JOURNAL OF SOUND AND VIBRATION, 2018, 433 :1-15
[7]  
Chopra AK, 1995, Dyn Struct
[8]  
Clough R., 1995, Dynamics of Structures, VThird
[9]   HYSTERETIC DAMPERS IN BASE ISOLATION - RANDOM APPROACH [J].
CONSTANTINOU, MC ;
TADJBAKHSH, IG .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1985, 111 (04) :705-721
[10]   Optimal design and seismic performance of tuned mass damper inerter (TMDI) for structures with nonlinear base isolation systems [J].
De Domenico, Dario ;
Ricciardi, Giuseppe .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (12) :2539-2560