An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging

被引:197
|
作者
Lois, Cristina [1 ,2 ]
Jakoby, Bjoern W. [1 ,3 ,4 ]
Long, Misty J. [1 ]
Hubner, Karl F. [1 ]
Barker, David W. [1 ]
Casey, Michael E. [3 ]
Conti, Maurizio [3 ]
Panin, Vladimir Y. [3 ]
Kadrmas, Dan J. [5 ]
Townsend, David W. [1 ]
机构
[1] Univ Tennessee, Med Ctr, Knoxville, TN USA
[2] Univ Santiago de Compostela, Dept Fis Particulas, Santiago De Compostela, Spain
[3] Siemens Healthcare Mol Imaging, Knoxville, TN 37932 USA
[4] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
[5] Univ Utah, Dept Radiol, Salt Lake City, UT 84132 USA
关键词
TOF; PET; PET/CT; lesion detectability; oncology; POSITRON-EMISSION-TOMOGRAPHY; RECONSTRUCTION; PERFORMANCE; SCANNER;
D O I
10.2967/jnumed.109.068098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of fast scintillators with good stopping power for 511-keV photons has renewed interest in time-of-flight (TOF) PET. The ability to measure the difference between the arrival times of a pair of photons originating from positron annihilation improves the image signal-to-noise ratio (SNR). The level of improvement depends upon the extent and distribution of the positron activity and the time resolution of the PET scanner. While specific estimates can be made for phantom imaging, the impact of TOF PET is more difficult to quantify in clinical situations. The results presented here quantify the benefit of TOF in a challenging phantom experiment and then assess both qualitatively and quantitatively the impact of incorporating TOF information into the reconstruction of clinical studies. A clear correlation between patient body mass index and gain in SNR was observed in this study involving 100 oncology patient studies, with a gain due to TOF ranging from 1.1 to 1.8, which is consistent with the 590-ps time resolution of the TOF PET scanner. The visual comparison of TOF and non-TOF images performed by two nuclear medicine physicians confirmed the advantages of incorporating TOF into the reconstruction, advantages that include better definition of small lesions and image details, improved uniformity, and noise reduction.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [21] Quantitative imaging characteristics of zirconium-89 on Gemini Time-Of-Flight PET/CT
    Alanazi, Sitah F.
    Alzimami, Khalid S.
    Ghannam, Magdy M.
    Aljammaz, Ibrahim J.
    Alrumayan, Faisal
    Sassi, Salem A.
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (12) : 1238 - 1245
  • [22] Recent developments in time-of-flight PET
    S. Vandenberghe
    E. Mikhaylova
    E. D’Hoe
    P. Mollet
    J. S. Karp
    EJNMMI Physics, 3
  • [23] Longitudinal monitoring of reconstructed activity concentration on a clinical time-of-flight PET/CT scanner
    MacDonald L.R.
    Perkins A.E.
    Tung C.-H.
    Journal of Medical Imaging, 2017, 4 (01)
  • [24] Performance of philips gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities
    Surti, Suleman
    Kuhn, Austin
    Werner, Matthew E.
    Perkins, Amy E.
    Kolthammer, Jeffrey
    Karp, Joel S.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (03) : 471 - 480
  • [25] Benefit of time-of-flight in PET: Experimental and clinical results
    Karp, Joel S.
    Surti, Sulernan
    Daube-Witherspoon, Margaret E.
    Muehllehner, Gerd
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (03) : 462 - 470
  • [26] Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector
    Chang, Chen-Ming
    Cates, Joshua W.
    Levin, Craig S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01) : 258 - 271
  • [27] Simultaneous MR-Compatible Emission and Transmission Imaging for PET Using Time-of-Flight Information
    Mollet, Pieter
    Keereman, Vincent
    Clementel, Enrico
    Vandenberghe, Stefaan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (09) : 1734 - 1742
  • [28] Performance evaluation of a new high-sensitivity time-of-flight clinical PET/CT system
    Li Huo
    Nan Li
    Heyu Wu
    Wenjia Zhu
    Haiqun Xing
    Jiantao Ba
    Tong Wang
    Fang Li
    Hui Zhang
    EJNMMI Physics, 5
  • [29] PETALO: Time-of-Flight PET with liquid xenon
    Romo-Luque, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 958
  • [30] Update on latest advances in time-of-flight PET
    Surti, Suleman
    Karp, Joel S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 251 - 258