An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging

被引:201
作者
Lois, Cristina [1 ,2 ]
Jakoby, Bjoern W. [1 ,3 ,4 ]
Long, Misty J. [1 ]
Hubner, Karl F. [1 ]
Barker, David W. [1 ]
Casey, Michael E. [3 ]
Conti, Maurizio [3 ]
Panin, Vladimir Y. [3 ]
Kadrmas, Dan J. [5 ]
Townsend, David W. [1 ]
机构
[1] Univ Tennessee, Med Ctr, Knoxville, TN USA
[2] Univ Santiago de Compostela, Dept Fis Particulas, Santiago De Compostela, Spain
[3] Siemens Healthcare Mol Imaging, Knoxville, TN 37932 USA
[4] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
[5] Univ Utah, Dept Radiol, Salt Lake City, UT 84132 USA
关键词
TOF; PET; PET/CT; lesion detectability; oncology; POSITRON-EMISSION-TOMOGRAPHY; RECONSTRUCTION; PERFORMANCE; SCANNER;
D O I
10.2967/jnumed.109.068098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of fast scintillators with good stopping power for 511-keV photons has renewed interest in time-of-flight (TOF) PET. The ability to measure the difference between the arrival times of a pair of photons originating from positron annihilation improves the image signal-to-noise ratio (SNR). The level of improvement depends upon the extent and distribution of the positron activity and the time resolution of the PET scanner. While specific estimates can be made for phantom imaging, the impact of TOF PET is more difficult to quantify in clinical situations. The results presented here quantify the benefit of TOF in a challenging phantom experiment and then assess both qualitatively and quantitatively the impact of incorporating TOF information into the reconstruction of clinical studies. A clear correlation between patient body mass index and gain in SNR was observed in this study involving 100 oncology patient studies, with a gain due to TOF ranging from 1.1 to 1.8, which is consistent with the 590-ps time resolution of the TOF PET scanner. The visual comparison of TOF and non-TOF images performed by two nuclear medicine physicians confirmed the advantages of incorporating TOF into the reconstruction, advantages that include better definition of small lesions and image details, improved uniformity, and noise reduction.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 15 条
[1]  
BUDINGER TF, 1983, J NUCL MED, V24, P73
[2]  
Comtat C, 2004, IEEE NUCL SCI CONF R, P3492
[3]   First experimental results of time-of-flight reconstruction on an LSO PET scanner [J].
Conti, M ;
Bendriem, B ;
Casey, M ;
Chen, M ;
Kehren, F ;
Michel, C ;
Panin, V .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4507-4526
[4]  
Jakoby B.W., 2008, IEEE NUCL SCI S C RE, P3738
[5]   Performance Characteristics of a New LSO PET/CT Scanner With Extended Axial Field-of-View and PSF Reconstruction [J].
Jakoby, Bjoern W. ;
Bercier, Yanic ;
Watson, Charles C. ;
Bendriem, Bernard ;
Townsend, David W. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) :633-639
[6]   Impact of Time-of-Flight on PET Tumor Detection [J].
Kadrmas, Dan J. ;
Casey, Michael E. ;
Conti, Maurizio ;
Jakoby, Bjoern W. ;
Lois, Cristina ;
Townsend, David W. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (08) :1315-1323
[7]   Benefit of time-of-flight in PET: Experimental and clinical results [J].
Karp, Joel S. ;
Surti, Sulernan ;
Daube-Witherspoon, Margaret E. ;
Muehllehner, Gerd .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (03) :462-470
[8]  
KARP JS, 2005, IEEE NUCL SCI S C RE
[9]   CERIUM-DOPED LUTETIUM OXYORTHOSILICATE - A FAST, EFFICIENT NEW SCINTILLATOR [J].
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :502-505
[10]   Prospects for time-of-flight PET using LSO scintillator [J].
Moses, WW ;
Derenzo, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :474-478